45 research outputs found

    Knee complaints seen in general practice: active sport participants versus non-sport participants

    Get PDF
    Background. Since knee complaints are common among athletes and are frequently presented in general practice, it is of interest to investigate the type of knee complaints represented in general practice of athletes in comparison with those of non-athletes. Therefore, the aim of this study is to investigate the differences in type of knee complaints between sport participants, in this study defined as athletes, and non-sport participants, defined as non-athletes, presenting in general practice. Further, differences in the initial policy of the GP, medical consumption, and outcome at one-year follow-up were also investigated. Methods. Patients consulting their GP for a new episode of knee complaints were invited to participate in this prospective cohort study. From the total HONEUR knee cohort population (n = 1068) we extracted patients who were athletes (n = 421) or non-athletes (n = 388). Results. The results showed that acute distortions of the knee were significantly more diagnosed in athletes than in non-athletes (p = 0.04). Further, more athletes were advised by their GP to 'go easy on the knee' than the non-athletes (p < 0.01), but no differences were found in number of referrals and medication prescribed by the GP. The medical consumption was significantly higher among athletes; however, no significant differences were found between the two groups for recovery at one-year follow-up. Conclusion. There are no major differences in the diagnosis and prognosis of knee complaints between athletes and non-athletes presented to the GP. This implies that there are no indications for different treatment strategies applied in both groups. However, athletes are more often advised to 'go easy on the knee' and to rest than non-athletes. Further, there is a trend towards increased medical consumption among athletes while functional disability and pain are lower than among the non-athletes

    High-Resolution Imaging of the Retinal Nerve Fiber Layer in Normal Eyes Using Adaptive Optics Scanning Laser Ophthalmoscopy

    Get PDF
    To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO).AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created.AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001)AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and MĂŒller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc

    Lateral Trunk Motion and Knee Pain in Osteoarthritis of the Knee: a cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients with osteoarthritis of the knee may change their gait in an attempt to reduce loading of the affected knee, thereby reducing pain. Especially changes in lateral trunk motion may be potentially effective, since these will affect the position of the centre of mass relative to the knee, enabling minimization of the load on the knee and thereby knee pain. The aim of the study was to test the hypothesis that a higher level of knee pain is associated with higher lateral trunk motion in patients with knee OA.</p> <p>Methods</p> <p>Fifty-two patients with OA of the knee were tested. Lateral trunk motion was measured during the stance phase of walking with an optoelectronic motion analysis system and a force plate. Knee pain was measured with the VAS and the WOMAC pain questionnaire. Regression analyses were performed to assess the relationship between lateral trunk motion and knee pain.</p> <p>Results</p> <p>It was shown that in bivariate analyses knee pain was not associated with lateral trunk motion. In regression analyses, pain was associated with more lateral trunk motion. In addition, more lateral trunk motion was associated with younger age, being female, higher self-reported knee stiffness and higher maximum walking speed.</p> <p>Conclusion</p> <p>Pain is associated with lateral trunk motion. This association is weak and is influenced by age, gender, self-reported stiffness and maximum walking speed.</p

    The effects of exercise and weight loss in overweight patients with hip osteoarthritis: design of a prospective cohort study

    Get PDF
    BACKGROUND: Hip osteoarthritis (OA) is recognised as a substantial source of disability, with pain and loss of function as principal symptoms. An aging society and a growing number of overweight people, which is considered a risk factor for OA, contribute to the growing number of cases of hip OA. In knee OA patients, exercise as a single treatment is proven to be very effective towards counteracting pain and physical functionality, but the combination of weight loss and exercise is demonstrated to be even more effective. Exercise as a treatment for hip OA patients is also effective, however evidence is lacking for the combination of weight loss and exercise. Consequently, the aim of this study is to get a first impression of the potential effectiveness of exercise and weight loss in overweight patients suffering from hip OA. METHODS/DESIGN: This is a prospective cohort study. Patients aged 25 or older, overweight (BMI > 25) or obese (BMI > 30), with clinical and radiographic evidence of OA of the hip and able to attend exercise sessions will be included. The intervention is an 8-month exercise and weight-loss lifestyle program. Main goal is to increase aerobic capacity, lose weight and stimulate a low-calorie and active lifestyle. Primary outcome is self-reported physical functioning. Secondary outcomes include pain, stiffness, health-related quality of life and habitual activity level. Weight loss in kilograms and percentage of fat-free mass will also be measured. DISCUSSION: The results of this study will give a first impression of potential effectiveness of exercise and weight loss as a combination program for patients with OA of the hip. Once this program is proven to be effective it may lead to postponing the moment of total hip replacement. TRIAL REGISTRATION NUMBER: NTR1053

    A Compact Multiphoton 3D Imaging System for Recording Fast Neuronal Activity

    Get PDF
    We constructed a simple and compact imaging system designed specifically for the recording of fast neuronal activity in a 3D volume. The system uses an Yb:KYW femtosecond laser we designed for use with acousto-optic deflection. An integrated two-axis acousto-optic deflector, driven by digitally synthesized signals, can target locations in three dimensions. Data acquisition and the control of scanning are performed by a LeCroy digital oscilloscope. The total cost of construction was one order of magnitude lower than that of a typical Ti:sapphire system. The entire imaging apparatus, including the laser, fits comfortably onto a small rig for electrophysiology. Despite the low cost and simplicity, the convergence of several new technologies allowed us to achieve the following capabilities: i) full-frame acquisition at video rates suitable for patch clamping; ii) random access in under ten microseconds with dwelling ability in the nominal focal plane; iii) three-dimensional random access with the ability to perform fast volume sweeps at kilohertz rates; and iv) fluorescence lifetime imaging. We demonstrate the ability to record action potentials with high temporal resolution using intracellularly loaded potentiometric dye di-2-ANEPEQ. Our design proffers easy integration with electrophysiology and promises a more widespread adoption of functional two-photon imaging as a tool for the study of neuronal activity. The software and firmware we developed is available for download at http://neurospy.org/ under an open source license

    Effectiveness of prolonged use of continuous passive motion (CPM), as an adjunct to physiotherapy, after total knee arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Adequate and intensive rehabilitation is an important requirement for successful total knee arthroplasty.</p> <p>Although research suggests that Continuous Passive Motion (CPM) should be implemented in the first rehabilitation phase after surgery, there is substantial debate about the duration of each session and the total period of CPM application. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered.</p> <p>Methods</p> <p>In a randomised controlled trial we investigated the effectiveness of prolonged CPM use in the home situation as an adjunct to standardised PT. Efficacy was assessed in terms of faster improvements in range of motion (RoM) and functional recovery, measured at the end of the active treatment period, 17 days after surgery.</p> <p>Sixty patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment were randomised over two treatment groups. The experimental group received CPM + PT for 17 consecutive days after surgery, whereas the usual care group received the same treatment during the in-hospital phase (i.e. about four days), followed by PT alone (usual care) in the first two weeks after hospital discharge.</p> <p>From 18 days to three months after surgery, both groups received standardised PT. The primary focus of rehabilitation was functional recovery (e.g. ambulation) and regaining RoM in the knee.</p> <p>Results</p> <p>Prolonged use of CPM slightly improved short-term RoM in patients with limited RoM at the time of discharge after total knee arthroplasty when added to a semi-standard PT programme. Assessment at 6 weeks and three months after surgery found no long-term effects of this intervention Neither did we detect functional benefits of the improved RoM at any of the outcome assessments.</p> <p>Conclusion</p> <p>Although results indicate that prolonged CPM use might have a small short-term effect on RoM, routine use of prolonged CPM in patients with limited RoM at hospital discharge should be reconsidered, since neither long-term effects nor transfer to better functional performance was detected.</p> <p>Trial Registration</p> <p>ISRCTN85759656</p

    Calibrating ADL-IADL scales to improve measurement accuracy and to extend the disability construct into the preclinical range: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Interest in measuring functional status among nondisabled older adults has increased in recent years. This is, in part, due to the notion that adults identified as 'high risk' for functional decline portray a state that is potentially easier to reverse than overt disability. Assessing relatively healthy older adults with traditional self-report measures (activities of daily living) has proven difficult because these instruments were initially developed for institutionalised older adults. Perhaps less evident, are problems associated with change scores and the potential for 'construct under-representation', which reflects the exclusion of important features of the construct (e.g., disability). Furthermore, establishing a formal hierarchy of functional status tells more than the typical simple summation of functional loss, and may have predictive value to the clinician monitoring older adults: if the sequence task difficulty is accelerated or out of order it may indicate the need for interventions.</p> <p>Methods</p> <p>This review identified studies that employed item response theory (IRT) to examine or revise functional status scales. IRT can be used to transform the ordinal nature of functional status scales to interval level data, which serves to increase diagnostic precision and sensitivity to clinical change. Furthermore, IRT can be used to rank items unequivocally along a hierarchy based on difficulty. It should be noted that this review is not concerned with contrasting IRT with more traditional classical test theory methodology.</p> <p>Results</p> <p>A systematic search of four databases (PubMed, Embase, CINAHL, and PsychInfo) resulted in the review of 2,192 manuscripts. Of these manuscripts, twelve met our inclusion/exclusion requirements and thus were targeted for further inspection.</p> <p>Conclusions</p> <p>Manuscripts presented in this review appear to summarise gerontology's best efforts to improve construct validity and content validity (i.e., ceiling effects) for scales measuring the early stages of activity restriction in community-dwelling older adults. Several scales in this review were exceptional at reducing ceiling effects, reducing gaps in coverage along the construct, as well as establishing a formal hierarchy of functional decline. These instrument modifications make it plausible to detect minor changes in difficulty for IADL items positioned at the edge of the disability continuum, which can be used to signal the onset of progressive type disability in older adults.</p

    Video-rate nonlinear microscopy of neuronal membrane dynamics with genetically encoded probes.

    No full text
    Biological membranes decorated with suitable contrast agents give rise to nonlinear optical signals such as two-photon fluorescence and harmonic up-conversion when illuminated with ultra-short, high-intensity pulses of infrared laser light. Microscopic images based on these nonlinear contrasts were acquired at video or higher frame rates by scanning a focused illuminating spot rapidly across neural tissues. The scan engine relied on an acousto-optic deflector (AOD) to produce a fast horizontal raster and on corrective prisms to offset the AOD-induced dispersion of the ultra-short excitation light pulses in space and time. Two membrane-bound derivatives of the green fluorescent protein (GFP) were tested as nonlinear contrast agents. Synapto-pHluorin, a pH-sensitive GFP variant fused to a synaptic vesicle membrane protein, provided a time-resolved fluorescent read-out of neurotransmitter release at genetically specified synaptic terminals in the intact brain. Arrays of dually lipidated GFP molecules at the plasma membrane generated intense two-photon fluorescence but no detectable second-harmonic power. Comparison with second-harmonic generation by membranes stained with a synthetic styryl dye suggested that the genetically encoded chromophore arrangement lacked the orientational anisotropy and/or dipole density required for efficient coherent scattering of the incident optical field

    Transmission of olfactory information between three populations of neurons in the antennal lobe of the fly.

    No full text
    Three classes of neurons form synapses in the antennal lobe of Drosophila, the insect counterpart of the vertebrate olfactory bulb: olfactory receptor neurons, projection neurons, and inhibitory local interneurons. We have targeted a genetically encoded optical reporter of synaptic transmission to each of these classes of neurons and visualized population responses to natural odors. The activation of an odor-specific ensemble of olfactory receptor neurons leads to the activation of a symmetric ensemble of projection neurons across the glomerular synaptic relay. Virtually all excited glomeruli receive inhibitory input from local interneurons. The extent, odor specificity, and partly interglomerular origin of this input suggest that inhibitory circuits assemble combinatorially during odor presentations. These circuits may serve as dynamic templates that extract higher order features from afferent activity patterns
    corecore