85 research outputs found

    Percutaneous retrieval of a broken catheter from the left atrium in an adult.

    Get PDF
    We performed a percutaneous retrieval of a broken catheter from the left atrium in an adult patient using transseptal left heart catheterization and a helical basket guidewire. To our knowledge, this is the first description of such a therapeutical option for a foreign body lodged in the left atrium of an adult patient

    Updated Meta-Analysis of Randomized Trials Comparing Safety and Efficacy of Intraoperative Defibrillation Testing with No Defibrillation Testing On Implantable Cardioverter-Defibrillator Implantation

    Get PDF
    Introduction: There is an ongoing debate regarding the need to conduct intraoperative defibrillation testing (DFT) at the time of implantable cardioverter-defibrillator (ICD) implantation. To provide sufficiently strong evidence for the feasibility of omitting intraoperative DFT in clinical practice, we conducted a meta-analysis of randomized controlled trials (RCT) comparing patients with DFT and no-DFT.Methods: We systematically searched Medline (via PubMed), ClinicalTrial.gov, the Cochrane Central Register of Controlled Trials, and Embase for studies evaluating DFT vs. no-DFT on ICD implantation with regard to total mortality and arrhythmic death, efficacy of first and any appropriate shock in interrupting ventricular tachycardia (VT)/ventricular fibrillation (VF), and procedural adverse events. Effect estimates [risk ratio (RR) with 95% confidence intervals (CI)] were pooled using the random-effects model.Results: Our meta-analysis included 4 RCTs comprising 3770 patients (1896 with DFT and 1874 without DFT). Total mortality (RR = 1.00, 95% CI 0.86–1.17; P = 0.98) and arrhythmic death (RR = 1.60, 95% CI 0.46-5.59: P = 0.46) were not statistically different. Both first (RR = 0.94, 95% CI 0.89–0.98; P = 0.004) and any appropriate ICD shock (RR = 0.97, 95% CI 0.95–1.00; P = 0.02) significantly increased the rate of VT/VF interruption in the group with no-DFT in comparison with DFT. Finally, the incidence of adverse events was lower in no-DFT patients (RR = 1.23; 95% CI 1.00–1.51; P = 0.05).Conclusions: The practice of DFT (as opposed to no-DFT) did not yield benefits in mortality or the overall rate of conversion of VT/VT. Moreover, a slightly higher incidence of perioperative adverse events was observed in the DFT group

    Totally percutaneous valve replacement for severe aortic regurgitation in a degenerating bioprosthesis

    Get PDF
    Recently, the feasibility and safety of percutaneous aortic valve replacement (PAVR) has been reported in the treatment of degenerative aortic valve stenosis in patients at high-risk for surgical aortic valve replacement (AVR).1 However, so far this therapy has been limited to patients with severe stenosis of the native valve. We report the case of a patient with severe aortic regurgitation owing to bioprosthesis dysfunction who was successfully treated by implantation of a CoreValve (CoreValve Inc, Irvine. Calif) prosthesis with a totally percutaneous approach

    Randomized comparison between 3-month Cre8 DES vs. 1-month Vision/Multilink8 BMS neointimal coverage assessed by OCT evaluation: The DEMONSTRATE study

    Get PDF
    AbstractBackgroundIt has been hypothesized that incomplete endothelialization and delayed vascular healing may trigger stent thrombosis events after drug-eluting stent (DES) implantation. We aimed to demonstrate non-inferiority in terms of neointimal coverage of novel Cre8 DES at 3months, compared to Vision/Multilink8 Bare Metal Stent (BMS) at 1month.MethodsThe ranDomizEd coMparisOn betweeN novel Cre8 DES and BMS to assess neoinTimal coveRAge by OCT Evaluation (DEMONSTRATE) was a multicenter, randomized, parallel group study. Thirty-eight patients undergoing angioplasty of de-novo coronary lesion were randomized to Cre8 (19) or Vision/Multilink8 (19) stent placement at 6 OCT-experienced centers. Primary end-point was the Ratio of Uncovered to Total Stent Struts Per Cross Section (RUTTS) score of <30%, determined by OCT at 3 and 1months for Cre8 and Vision/Multilink8, respectively. Percentage of uncovered/malapposed stent struts, neointimal growth and thickness were the main secondary end-points.ResultsThe primary end-point of RUTTS score <30% occurred in 99.8% (899/901) of Cre8 struts and in 99.6% (1116/1121) of Vision/Multilink8 struts (difference 0.2, CI 95% −0.2 to 0.6, p for noninferiority <0.001). The percentage of uncovered/malapposed struts was comparable (0.36±0.64 vs. 0.12±0.24, p=0.145) in the two study groups, while both neointimal percentage area (8.46±5.29 vs. 19.84±15.93, p<0.001) and thickness (0.07±0.04 vs. 0.16±0.12, p<0.001) were significantly reduced by Cre8 stent.ConclusionsThe Cre8 DES at 3months has comparable strut coverage to Vision/Multilink8 BMS at 1month while preserving a greater efficacy in neo-intima formation reduction. Further studies to assess clinical implication of these Cre8 characteristics are warranted

    Case report: Complete pathologic response with first-line immunotherapy combination in a young adult with massive liver dissemination of mismatch repair–deficient metastatic colorectal cancer: Immunological and molecular profiling

    Get PDF
    The current level of evidence for immunotherapy in previously untreated microsatellite unstable metastatic colorectal cancer is based on recent pieces of evidence of few studies that demonstrated durable response and clinical benefit, in terms of objective response rate, disease control rate, and progression-free survival in this subgroup of patients. On the basis of combinatorial immunotherapy with nivolumab plus ipilimumab, we report the exceptional case of a complete pathological response in a 21-year-old woman presenting a clinically aggressive stage IV colorectal cancer with massive nodal and liver involvement. Extensive molecular analyses based on whole genome next-generation DNA sequencing, RNA sequencing, fluorescent multiplex immunohistochemistry, and flow cytometry provided a detailed description of tumoral and immunological characteristics of this noteworthy clinical case

    Intimal hyperplasia and cystic medial necrosis as substrate of acute coronary syndrome in a cocaine abuser: an in vivo/ex vivo pathological correlation.

    No full text
    Identification of pathological substrate of degenerative remodeling of coronary artery causing acute coronary syndrome in a cocaine abuse

    Refractory angina with severe left ventricular dysfunction: a case for percutaneous transseptal ventricular assistance supported revascularization.

    No full text
    A 73-year-old female patient with medical refractory angina, severe multivessel disease and a critically depressed left ventricular function (ejection fraction 30%) was admitted to our hospital. Considered a poor candidate for surgical revascularization, she underwent urgent high-risk revascularization supported by use of a novel percutaneous left ventricular assist system
    • …
    corecore