914 research outputs found

    Ecdysteroids and oocyte development in the black fly Simulium vittatum

    Get PDF
    BACKGROUND: Oocyte development was studied in the autogenous black fly, Simulium vittatum (Diptera, Nematocera), a vector of Onchocerca volvulus, the causative agent of onchocerciasis. RESULTS: Oocyte growth was nearly linear between adult eclosion and was complete by 72 hours at 21°C. The oocyte became opaque at 14 hours after eclosion indicating the initiation of protein yolk deposition. The accumulation of vitellogenin was measured using SDS-PAGE. The density of the yolk protein bands at about 200 and 65 kDa increased during the first and second days after eclosion. The amount of protein in the 200 kDa band of vitellogenin, determined using densitometry, rapidly increased between 12 and 25 hours after eclosion. Ecdysteroid levels were measured using a competitive ELISA. Ecdysteroid levels increased rapidly and subsequently declined during the first day after eclosion. CONCLUSION: These data show a correlation between the appearance of vitellogenin in the oocyte, and the rise in ecdysteroids. A possible relationship to molting of the nematode, Onchocerca volvulus, is discussed

    Torsion Tests of Tubes

    Get PDF
    This report presents the results of tests of 63 chromium-molybdenum steel tubes and 102 17st aluminum-alloy tubes of various sizes and lengths made to study the dependence of the torsional strength on both the dimensions of the tube and the physical properties of the tube material. Three types of failure are found to be important for sizes of tubes frequently used in aircraft construction: (1) failure by plastic shear, in which the tube material reached its yield strength before the critical torque was reached; (2) failure by elastic two-lobe buckling, which depended only on the elastic properties of the tube material and the dimensions of the tube; and (3) failure by a combination of (1) and (2) that is, by buckling taking place after some yielding of the tube material

    New Fast Shower Max Detector Based on MCP as an Active Element

    Get PDF
    One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photo detectors based on micro channel plates (MCP) as secondary emitter. The SM time resolution – we obtained for this new type of detector is at the level of 20-30 ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP

    Quartz Cherenkov Counters for Fast Timing: QUARTIC

    Full text link
    We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps). One application is to measure the times of small angle protons from exclusive reactions, e.g. p + p - p + H + p, at the Large Hadron Collider, LHC. They may also be used to measure directional particle fluxes close to external or stored beams. The detectors have small areas (square cm), but need to be active very close (a few mm) to the intense LHC beam, and so must be radiation hard and nearly edgeless. We present results of tests of detectors with quartz bars inclined at the Cherenkov angle, and with bars in the form of an "L" (with a 90 degree corner). We also describe a possible design for a fast timing hodoscope with elements of a few square mm.Comment: 24 pages, 14 figure

    The CP-violating asymmetry in K_L -> pi+ pi- e+ e-

    Full text link
    We update the theoretical analysis of the CP-violating asymmetry in the decay K_L -> pi+ pi- e+ e-, relying on chiral perturbation theory and on the most recent phenomenological information. With the experimentally determined magnetic amplitude and branching ratio as input, the asymmetry can be calculated with good accuracy. The theoretical interpretation of the sign of the asymmetry is discussed.Comment: 11 page

    Expression of Interest: The Atmospheric Neutrino Neutron Interaction Experiment (ANNIE)

    Get PDF
    Submitted for the January 2014 Fermilab Physics Advisory Committee meetingSubmitted for the January 2014 Fermilab Physics Advisory Committee meetingSubmitted for the January 2014 Fermilab Physics Advisory Committee meetingSubmitted for the January 2014 Fermilab Physics Advisory Committee meetingNeutron tagging in Gadolinium-doped water may play a significant role in reducing backgrounds from atmospheric neutrinos in next generation proton-decay searches using megaton-scale Water Cherenkov detectors. Similar techniques might also be useful in the detection of supernova neutrinos. Accurate determination of neutron tagging efficiencies will require a detailed understanding of the number of neutrons produced by neutrino interactions in water as a function of momentum transferred. We propose the Atmospheric Neutrino Neutron Interaction Experiment (ANNIE), designed to measure the neutron yield of atmospheric neutrino interactions in gadolinium-doped water. An innovative aspect of the ANNIE design is the use of precision timing to localize interaction vertices in the small fiducial volume of the detector. We propose to achieve this by using early production of LAPPDs (Large Area Picosecond Photodetectors). This experiment will be a first application of these devices demonstrating their feasibility for Water Cherenkov neutrino detectors

    Precision Timing with Silicon Sensors for Use in Calorimetry

    Get PDF
    The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 × 10^(34) cm^(−2) s^(−1). The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL- LHC and future collider experiments which face very high radiation environments. We present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. We show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor
    corecore