46 research outputs found

    Platelet function is disturbed by the angiogenesis inhibitors sunitinib and sorafenib, but unaffected by bevacizumab

    Get PDF
    Introduction: At the clinical introduction of antiangiogenic agents as anticancer agents, no major toxicities were expected as merely just endothelial cells (ECs) in tumors would be affected. However, several (serious) toxicities became apparent, of which underlying mechanisms are largely unknown. We investigated to what extent sunitinib (multitargeted antiangiogenic tyrosine kinase inhibitor (TKI)), sorafenib (TKI) and bevacizumab [specific antibody against vascular endothelial growth factor (VEGF)] may impair platelet function, which might explain treatment-related bleedings. Materials and methods: In vitro, the influence of sunitinib, sorafenib, and bevacizumab on platelet aggregation, P-selectin expression and fibrinogen binding, platelet–EC interaction, and tyrosine phosphorylation of c-Src was studied by optical aggregation, flow cytometry, real-time perfusion, and western blotting. Ex vivo, platelet aggregation was analyzed in 25 patients upon sunitinib or bevacizumab treatment. Concentrations of sunitinib, VEGF, and platelet and EC activation markers were measured by LC–MS/MS and ELISA. Results: In vitro, sunitinib and sorafenib significantly inhibited platelet aggregation (20 μM sunitinib: 71.3%, p < 0.001; 25 μM sorafenib: 55.8%, p = 0.042). Sorafenib and sunitinib significantly inhibited P-selectin expression on platelets. Exposure to both TKIs resulted in a reduced tyrosine phosphorylation of c-Src. Ex vivo, within 24 h sunitinib impaired platelet aggregation (83.0%, p = 0.001, N = 8). Plasma concentrations of sunitinib, VEGF, and platelet/EC activation markers were not correlated with disturbed aggregation. In contrast, bevacizumab only significantly impaired platelet aggregation in vitro at high c

    Limited clinical activity of palbociclib and ribociclib monotherapy in advanced cancers with cyclin D-CDK4/6 pathway alterations in the Dutch DRUP and Australian MoST trials

    Get PDF
    The Dutch Drug Rediscovery Protocol (DRUP) and the Australian Cancer Molecular Screening and Therapeutic (MoST) Program are similar nonrandomized, multidrug, pan-cancer trial platforms that aim to identify signals of clinical activity of molecularly matched targeted therapies or immunotherapies outside their approved indications. Here, we report results for advanced or metastatic cancer patients with tumors harboring cyclin D-CDK4/6 pathway alterations treated with CDK4/6 inhibitors palbociclib or ribociclib. We included adult patients that had therapy-refractory solid malignancies with the following alterations: amplifications of CDK4, CDK6, CCND1, CCND2 or CCND3, or complete loss of CDKN2A or SMARCA4. Within MoST, all patients were treated with palbociclib, whereas in DRUP, palbociclib and ribociclib were assigned to different cohorts (defined by tumor type and alteration). The primary endpoint for this combined analysis was clinical benefit, defined as confirmed objective response or stable disease ≥16 weeks. We treated 139 patients with a broad variety of tumor types; 116 with palbociclib and 23 with ribociclib. In 112 evaluable patients, the objective response rate was 0% and clinical benefit rate at 16 weeks was 15%. Median progression-free survival was 4 months (95% CI: 3-5 months), and median overall survival 5 months (95% CI: 4-6 months). In conclusion, only limited clinical activity of palbociclib and ribociclib monotherapy in patients with pretreated cancers harboring cyclin D-CDK4/6 pathway alterations was observed. Our findings indicate that monotherapy use of palbociclib or ribociclib is not recommended and that merging data of two similar precision oncology trials is feasible.Experimentele farmacotherapi

    Safety and efficacy of the ChAdOx1 nCoV-19 vaccine (AZD1222) against SARS-CoV-2: an interim analysis of four randomised controlled trials in Brazil, South Africa, and the UK.

    Get PDF
    BACKGROUND: A safe and efficacious vaccine against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), if deployed with high coverage, could contribute to the control of the COVID-19 pandemic. We evaluated the safety and efficacy of the ChAdOx1 nCoV-19 vaccine in a pooled interim analysis of four trials. METHODS: This analysis includes data from four ongoing blinded, randomised, controlled trials done across the UK, Brazil, and South Africa. Participants aged 18 years and older were randomly assigned (1:1) to ChAdOx1 nCoV-19 vaccine or control (meningococcal group A, C, W, and Y conjugate vaccine or saline). Participants in the ChAdOx1 nCoV-19 group received two doses containing 5 × 1010 viral particles (standard dose; SD/SD cohort); a subset in the UK trial received a half dose as their first dose (low dose) and a standard dose as their second dose (LD/SD cohort). The primary efficacy analysis included symptomatic COVID-19 in seronegative participants with a nucleic acid amplification test-positive swab more than 14 days after a second dose of vaccine. Participants were analysed according to treatment received, with data cutoff on Nov 4, 2020. Vaccine efficacy was calculated as 1 - relative risk derived from a robust Poisson regression model adjusted for age. Studies are registered at ISRCTN89951424 and ClinicalTrials.gov, NCT04324606, NCT04400838, and NCT04444674. FINDINGS: Between April 23 and Nov 4, 2020, 23 848 participants were enrolled and 11 636 participants (7548 in the UK, 4088 in Brazil) were included in the interim primary efficacy analysis. In participants who received two standard doses, vaccine efficacy was 62·1% (95% CI 41·0-75·7; 27 [0·6%] of 4440 in the ChAdOx1 nCoV-19 group vs71 [1·6%] of 4455 in the control group) and in participants who received a low dose followed by a standard dose, efficacy was 90·0% (67·4-97·0; three [0·2%] of 1367 vs 30 [2·2%] of 1374; pinteraction=0·010). Overall vaccine efficacy across both groups was 70·4% (95·8% CI 54·8-80·6; 30 [0·5%] of 5807 vs 101 [1·7%] of 5829). From 21 days after the first dose, there were ten cases hospitalised for COVID-19, all in the control arm; two were classified as severe COVID-19, including one death. There were 74 341 person-months of safety follow-up (median 3·4 months, IQR 1·3-4·8): 175 severe adverse events occurred in 168 participants, 84 events in the ChAdOx1 nCoV-19 group and 91 in the control group. Three events were classified as possibly related to a vaccine: one in the ChAdOx1 nCoV-19 group, one in the control group, and one in a participant who remains masked to group allocation. INTERPRETATION: ChAdOx1 nCoV-19 has an acceptable safety profile and has been found to be efficacious against symptomatic COVID-19 in this interim analysis of ongoing clinical trials. FUNDING: UK Research and Innovation, National Institutes for Health Research (NIHR), Coalition for Epidemic Preparedness Innovations, Bill & Melinda Gates Foundation, Lemann Foundation, Rede D'Or, Brava and Telles Foundation, NIHR Oxford Biomedical Research Centre, Thames Valley and South Midland's NIHR Clinical Research Network, and AstraZeneca

    Safety and efficacy of the ChAdOx1 nCoV-19 vaccine (AZD1222) against SARS-CoV-2: an interim analysis of four randomised controlled trials in Brazil, South Africa, and the UK

    Get PDF
    Background A safe and efficacious vaccine against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), if deployed with high coverage, could contribute to the control of the COVID-19 pandemic. We evaluated the safety and efficacy of the ChAdOx1 nCoV-19 vaccine in a pooled interim analysis of four trials. Methods This analysis includes data from four ongoing blinded, randomised, controlled trials done across the UK, Brazil, and South Africa. Participants aged 18 years and older were randomly assigned (1:1) to ChAdOx1 nCoV-19 vaccine or control (meningococcal group A, C, W, and Y conjugate vaccine or saline). Participants in the ChAdOx1 nCoV-19 group received two doses containing 5 × 1010 viral particles (standard dose; SD/SD cohort); a subset in the UK trial received a half dose as their first dose (low dose) and a standard dose as their second dose (LD/SD cohort). The primary efficacy analysis included symptomatic COVID-19 in seronegative participants with a nucleic acid amplification test-positive swab more than 14 days after a second dose of vaccine. Participants were analysed according to treatment received, with data cutoff on Nov 4, 2020. Vaccine efficacy was calculated as 1 - relative risk derived from a robust Poisson regression model adjusted for age. Studies are registered at ISRCTN89951424 and ClinicalTrials.gov, NCT04324606, NCT04400838, and NCT04444674. Findings Between April 23 and Nov 4, 2020, 23 848 participants were enrolled and 11 636 participants (7548 in the UK, 4088 in Brazil) were included in the interim primary efficacy analysis. In participants who received two standard doses, vaccine efficacy was 62·1% (95% CI 41·0–75·7; 27 [0·6%] of 4440 in the ChAdOx1 nCoV-19 group vs71 [1·6%] of 4455 in the control group) and in participants who received a low dose followed by a standard dose, efficacy was 90·0% (67·4–97·0; three [0·2%] of 1367 vs 30 [2·2%] of 1374; pinteraction=0·010). Overall vaccine efficacy across both groups was 70·4% (95·8% CI 54·8–80·6; 30 [0·5%] of 5807 vs 101 [1·7%] of 5829). From 21 days after the first dose, there were ten cases hospitalised for COVID-19, all in the control arm; two were classified as severe COVID-19, including one death. There were 74 341 person-months of safety follow-up (median 3·4 months, IQR 1·3–4·8): 175 severe adverse events occurred in 168 participants, 84 events in the ChAdOx1 nCoV-19 group and 91 in the control group. Three events were classified as possibly related to a vaccine: one in the ChAdOx1 nCoV-19 group, one in the control group, and one in a participant who remains masked to group allocation. Interpretation ChAdOx1 nCoV-19 has an acceptable safety profile and has been found to be efficacious against symptomatic COVID-19 in this interim analysis of ongoing clinical trials

    Tailorable Trimethyl chitosans as adjuvant for intranasal immunization

    No full text
    Tailorable Trimethyl Chitosans as Adjuvant for Intranasal Immunization Active vaccination has proven to be the most (cost) effective tool in the fight against infectious diseases. Nowadays, most vaccines are administered via parenteral injection. However, the risk of contaminated needles and need for trained personnel have risen interest in alternative immunization routes. As live attenuated vaccines raise considerable safety issues, (nasal) vaccine development now mainly focuses on purified, well-characterized antigenic proteins. However, these subunit vaccines are generally less immunogenic and need potent adjuvant (system)s to elicit an adequate immune response. The use of muco-adhesive polymers like N,N,N-trimethylchitosan (TMC), a partially quaternized, water-soluble chitosan derivative, can enhance the immune responses against antigens. In this thesis novel synthetic methods are presented to obtain structural variants of TMC that allow tailorability of the degrees of quaternization (DQ) and acetylation (DAc) and exclude the introduction of other alterations such as O-methylation (DOM)and polymer chain scission. Additionally, thiol-moieties are introduced in a controllable manner to yield thiolated TMC. This tailorability of TMC provided the possibility to properly establish structure-activity-relationships in in vitro biological assays and in in vivo (nasal) vaccination studies. On Caco-2, cells O-methyl free TMCs demonstrated a larger decrease in trans-epithelial electrical resistance (TEER) than O-methylated TMCs while TMCs with a high DAc (~50%), were not able to open tight junctions. Also, with increasing DQ, an increase in cytotoxicity (MTT) and membrane permeability (LDH) was observed. On the other hand, TMCs with a high DAc (~50%) demonstrated no cell toxicity (MTT, LDH release) up to a concentration of 10 mg/ml. The extent of lysozyme-catalyzed degradation of TMC was highly dependent on the DAc; polymers with the highest DAc showed the largest decrease in molecular weight. Using Calu-3 cells, XTT and LDH cell viability tests showed a slight reduction in cytotoxicity for thiolated TMCs as compared to the non-thiolated polymers with similar DQs. The adjuvant properties of TMCs as nasal adjuvant in mice, using whole inactivated influenza virus as antigen, were strongly decreased by re-acetylation of TMC, whereas the DQ and DOM hardly affected the adjuvanticity of TMC. The inferior adjuvant effect of TMC-RA over that of TMC might be caused by a slightly lower stability of TMC-RA in the nasal cavity. In vitro experiments with human and murine dendritic cells indicated that the degree of N-acetylation is critical for the adjuvant effect of TMC on human DCs, but not on mice DCs. Finally, a covalently-stabilized polymeric nanocarrier system was introduced based upon the formation of intracellularly degradable disulfides between thiolated TMC (TMC-SH) and (oppositely charged) thiolated hyaluronic acid (HA-SH). Stabilized TMC-S-S-HA nanoparticles showed superior stability in saline solutions compared to non-stabilized particles (composed of non-thiolated polymers), but readily disintegrated when a disulfide reducing agent was introduced. In both the nasal and intradermal immunization study, Ovalbumin-loaded stabilized TMC-S-S-HA particles demonstrated superior immunogenicity compared to non-stabilized particles. Further research is required to investigate the potential applications for these novel TMC(-systems) in nasal vacci

    Polypropylene–rubber blends: 4. The effect of the rubber particle size on the fracture behaviour at low and high test speed

    Get PDF
    The effect of the rubber particle size and rubber content on the fracture behaviour of polypropylene–EPR blends was studied at low and high test speeds. The particle size was varied by changing the molecular weight of the EPR phase, and ranged from about 0.5 to around 4.0 μm. The fracture behaviour was determined as a function of temperature by the notched Izod impact test (high test speed) and by a tensile test on notched Izod bars at 1 mm/s (low test speed). At high test speed the brittle–ductile transition temperature (Tbd) increases with increasing particle size. At low test speed the Tbd decreases slightly with increasing particle size. The weight average particle size gave a better correlation with the notched Izod results than the number average particle size. This suggests that the larger particles initiate the fracture more easily

    Decay of^{112,113,114}Te and^{115}Te^{g+m}

    Get PDF

    Decay of^{111,112,113,114,115}Sb

    Get PDF

    Static Strength of High Strength Steel Tubular Joints

    No full text
    Civil Engineering and GeosciencesStructural Engineerin
    corecore