175 research outputs found

    Wet Etching and Surface Analysis of Chemically Treated InGaN Films

    Get PDF
    This paper discusses the performance of different wet chemical etchants on InGaN. It is shown that certain etchants can be used to chemically etch and remove appreciable amounts of InGaN even though the etch rate is not as high as observed for other III-V materials. The performance of etchants studied here were (i) two different ratios of HF, HNO3, (ii) cyclic usage of NH4OH followed by HCl, (iii) hot H2SO4 and H3PO4 mixture, and (iv) conc. NH4OH. The etched surfaces have then been analyzed by x-ray photoelectron spectroscopy (XPS). Different etch residues were observed on the top surface. These results suggest an alternative to reactive plasma etching or photo-enhanced electrochemical etching of InGaN type materials. Based on the observed performance of the etchants studied, it was also possible to segregate the surface cleaning protocols and etchants

    Band-Bending at Buried SiO2/Si Interface as Probed by XPS

    Get PDF
    Cataloged from PDF version of article.X-ray photoelectron spectroscopy is used to probe the photoinduced shifts in the binding energies of Si2p, O1s, and C1s of the SiO2/Si interfaces of a number of samples having oxide and/or thin organic layers on top of p- and n-Si wafers. Whereas the photoinduced shifts, in each and every peak related, vary from 0.2 to 0.5 eV for the p-type samples, the corresponding shifts are substantially smaller (<0.1 eV) for the n-type, regardless of (i) oxidation route (thermal or anodic), (ii) thickness of oxide layer, (iii) nature of organic layer, or (iv) color of three illuminating sources we have used. This leads us to conclude that these particular photoshifts reflect the charge state of the SiO2/Si interface, even in the case of a 20 nm thick oxide, where the interface is buried and cannot be probed directly by XPS

    Oxidation of TaSi2-Containing ZrB2-SiC Ultra-High Temperature Materials

    Get PDF
    Hot pressed coupons of composition ZrB2-20 v% SiC-5 v% TaSi2 and ZrB2-20 v% SiC-20 v% TaSi2 were oxidized in stagnant air at temperatures of 1627 and 1927C for one, five and ten 10-minute cycles. The oxidation reactions were characterized by weight change kinetics, x-ray diffraction, and SEM/EDS. Detailed WDS/microprobe quantitative analyses of the oxidation products were conducted for the ZrB2-20 v% SiC-20 v% TaSi2 sample oxidized for five 10-minute cycles at 1927C. Oxidation kinetics and product formation were compared to ZrB2-20 v% SiC with no TaSi2 additions. It was found that the 20 v% TaSi2 composition exhibited improved oxidation resistance relative to the material with no TaSi2 additions at 1627C. However, for exposures at 1927C less oxidation resistance and extensive liquid phase formation were observed compared to the material with no TaSi2 additions. Attempts to limit the liquid phase formation by reducing the TaSi2 content to 5 v% were unsuccessful. In addition, the enhanced oxidation resistance at 1627C due to 20 v% TaSi2 additions was not achieved at the 5 v% addition level. The observed oxidation product evolution is discussed in terms of thermodynamics and phase equilibria for the TaSi2-containing ZrB2-SiC material system. TaSi2-additions to ZrB2-SiC at any level are not recommended for ultra-high temperature (>1900C) applications due to excessive liquid phase formation

    Robust UHTC for Sharp Leading Edge Applications

    Get PDF
    Ultrahigh temperature ceramics have performed unreliably due to material flaws and attachment design. These deficiencies are brought to the fore by the low fracture toughness and thermal shock resistance of UHTCs. If these deficiencies are overcome, we are still faced with poor oxidation resistance as a limitation on UHTC applicability to reusable launch vehicles. We have been addressing the deficiencies of UHTCs for the past year via a small task at GRC that is part of the 3rd Gen TPS effort. Our focus is on composite constructions and functional grading to address the mechanical issues and on composition modification to address the oxidation issue. The approaches and progress will be reported

    Characterization of a Ultra-high Temperature Ceramic Composite

    Get PDF
    Ultra-high temperature ceramics (UHTC) are of interest for hypersonic vehicle leading edge applications. Monolithic UHTCs are of concern because of their low fracture toughness and brittle behavior. UHTC composites (UHTCC) are being investigated as a possible approach to overcome these deficiencies. In this study a small sample of a UHTCC was evaluated by limited mechanical property tests, furnace oxidation exposures, and oxidation exposures in a flowing environment. The composite was prepared from a carbon fiber perform using ceramic particulates and a preceramic polymer. The as-received composite plate was non-uniform from front to back surface. Plate dimensions were 150 x 150 x 6 mm. The back surface had a fibrous, uniform appearance; XRD analysis revealed the presence of Sic and C. The front surface was smooth and non-uniform in appearance with evidence of a coarse grain structure produced by a liquid phase; XRD analysis revealed the presence of HfB2. Microcracks were present throughout the thickness as one might expect from a carbon fiber reinforced composite with attendant large thermal expansion mismatch between the matrix phases and the fibers. The HfB2 phase on the front surface was comparable in thickness to a fiber ply or about 0.6 mm, and surface microcracks were evident. Limited four point flexural tests were carried out at span to depth ratios of approximately 14 and 16 with markedly different results. Tests were run with the front or the back surface in tension. At the shorter span to depth failures occurred under a loading pin for both orientations. At a span to depth of 16 failures occurred in the center of the span with fracture clearly initiating from a tensile failure. Ultimate flexural strength, strain at ultimate stress, stress and strain at deviation from linear elastic behavior are reported. Strains at ultimate stress ranged from about 0.6 to 0.7 % for the back surface in tension, and 0.4 to 0.6 for the front surface in tension. At constant span to depth the strain at ultimate stress was about 0.2% greater for the back surface in tension and the ultimate strength was also higher. Strengths were in line with predictions from theory. Furnace oxidation studies were carried out at 1627 and 1927OC in a static furnace environment using ten minute cycles and one, five, and ten cycles. Limited oxidation studies were also carried out in a flowing oxyacetylene torch environment. Specimens were photographed, and weight and dimensional changes were determined. XRD and SEM characterizations were performed. Weight losses were attributed primarily to carbon fiber oxidation. The composite survived the torch test with little visible distress. Further details will be determined once metallographic studies are completed

    Primary care follow up of patients discharged from the emergency department: a retrospective study

    Get PDF
    BACKGROUND: The visit to the emergency department (ED) constitutes a brief, yet an important point in the continuum of medical care. The aim of our study was to evaluate the continuity of care of adult ED visitors. METHODS: We retrospectively reviewed all ED discharge summaries for over a month 's period. The ED chart, referral letter and the patient's primary care file were reviewed. Data collected included: age, gender, date and hour of ED visit, documentation of ED referral and ED discharge letter in the primary care file. RESULTS: 359 visits were eligible for the study. 192 (53.5%) of the patients were women, average age 54.1 ± 18.7 years (mean ± SD). 214 (59.6%) of the visits were during working hours of primary care clinics ("working hours"), while the rest were "out of hours" visits. Only 196 (54.6%) of patients had a referral letter, usually from their family physician. A third (71/214) of "working hours" visits were self referrals, the rate rose to 63.5% (92/145) of "out of hours" visits (p < 0.0001). The ED discharge letter was found in 50% (179/359) of the primary care files. A follow-up visit was documented in only 31% (111/359). Neither follow up visit nor discharge letter were found in 43% of the files (153/359). CONCLUSIONS: We have found a high rate of ED self referrals throughout the day together with low documentation rates of ED visits in the primary care charts. Our findings point to a poor continuity of care of ED attendees

    Movement Behavior of High-Heeled Walking: How Does the Nervous System Control the Ankle Joint during an Unstable Walking Condition?

    Get PDF
    The human locomotor system is flexible and enables humans to move without falling even under less than optimal conditions. Walking with high-heeled shoes constitutes an unstable condition and here we ask how the nervous system controls the ankle joint in this situation? We investigated the movement behavior of high-heeled and barefooted walking in eleven female subjects. The movement variability was quantified by calculation of approximate entropy (ApEn) in the ankle joint angle and the standard deviation (SD) of the stride time intervals. Electromyography (EMG) of the soleus (SO) and tibialis anterior (TA) muscles and the soleus Hoffmann (H-) reflex were measured at 4.0 km/h on a motor driven treadmill to reveal the underlying motor strategies in each walking condition. The ApEn of the ankle joint angle was significantly higher (p<0.01) during high-heeled (0.38±0.08) than during barefooted walking (0.28±0.07). During high-heeled walking, coactivation between the SO and TA muscles increased towards heel strike and the H-reflex was significantly increased in terminal swing by 40% (p<0.01). These observations show that high-heeled walking is characterized by a more complex and less predictable pattern than barefooted walking. Increased coactivation about the ankle joint together with increased excitability of the SO H-reflex in terminal swing phase indicates that the motor strategy was changed during high-heeled walking. Although, the participants were young, healthy and accustomed to high-heeled walking the results demonstrate that that walking on high-heels needs to be controlled differently from barefooted walking. We suggest that the higher variability reflects an adjusted neural strategy of the nervous system to control the ankle joint during high-heeled walking

    Quality and correlates of medical record documentation in the ambulatory care setting

    Get PDF
    BACKGROUND: Documentation in the medical record facilitates the diagnosis and treatment of patients. Few studies have assessed the quality of outpatient medical record documentation, and to the authors' knowledge, none has conclusively determined the correlates of chart documentation. We therefore undertook the present study to measure the rates of documentation of quality of care measures in an outpatient primary care practice setting that utilizes an electronic medical record. METHODS: We reviewed electronic medical records from 834 patients receiving care from 167 physicians (117 internists and 50 pediatricians) at 14 sites of a multi-specialty medical group in Massachusetts. We abstracted information for five measures of medical record documentation quality: smoking history, medications, drug allergies, compliance with screening guidelines, and immunizations. From other sources we determined physicians' specialty, gender, year of medical school graduation, and self-reported time spent teaching and in patient care. RESULTS: Among internists, unadjusted rates of documentation were 96.2% for immunizations, 91.6% for medications, 88% for compliance with screening guidelines, 61.6% for drug allergies, 37.8% for smoking history. Among pediatricians, rates were 100% for immunizations, 84.8% for medications, 90.8% for compliance with screening guidelines, 50.4% for drug allergies, and 20.4% for smoking history. While certain physician and patient characteristics correlated with some measures of documentation quality, documentation varied depending on the measure. For example, female internists were more likely than male internists to document smoking history (odds ratio [OR], 1.90; 95% confidence interval [CI], 1.27 – 2.83) but were less likely to document drug allergies (OR, 0.51; 95% CI, 0.35 – 0.75). CONCLUSIONS: Medical record documentation varied depending on the measure, with room for improvement in most domains. A variety of characteristics correlated with medical record documentation, but no pattern emerged. Further study could lead to targeted interventions to improve documentation
    • …
    corecore