4,626 research outputs found

    Flight control system design factors for applying automated testing techniques

    Get PDF
    Automated validation of flight-critical embedded systems is being done at ARC Dryden Flight Research Facility. The automated testing techniques are being used to perform closed-loop validation of man-rated flight control systems. The principal design features and operational experiences of the X-29 forward-swept-wing aircraft and F-18 High Alpha Research Vehicle (HARV) automated test systems are discussed. Operationally applying automated testing techniques has accentuated flight control system features that either help or hinder the application of these techniques. The paper also discusses flight control system features which foster the use of automated testing techniques

    Flow Dynamics And Plasma Heating Of Spheromaks In SSX

    Get PDF
    We report several new experimental results related to flow dynamics and heating from single dipole-trapped spheromaks and spheromak merging studies at SSX. Single spheromaks (stabilized with a pair of external coils, see Brown, Phys. Plasmas 13 102503 (2006)) and merged FRC-like configurations (see Brown, Phys. Plasmas 13, 056503 (2006)) are trapped in our prolate (R = 0.2 m, L = 0.6 m) copper flux conserver. Local spheromak flow is studied with two Mach probes (r(1) = rho(i) ) calibrated by time-of-flight with a fast set of magnetic probes at the edge of the device. Both Mach probes feature six ion collectors housed in a boron nitride sheath. The larger Mach probe will ultimately be used in the MST reversed field pinch. Line averaged flow is measured by ion Doppler spectroscopy (IDS) at the midplane. The SSX IDS instrument measures with 1 mu s or better time resolution the width and Doppler shift of the C-III impurity (H plasma) 229.7 nm line to determine the temperature and line-averaged flow velocity (see Cothran, RSI 77, 063504 (2006)). We find axial flows up to 100 km/s during formation of the dipole trapped spheromak. Flow returns at the wall to form a large vortex. Recent high-resolution IDS velocity measurements during spheromak merging show bi-directional outflow jets at +/- 40 km/s (nearly the Alfven speed). We also measure T-i \u3e= 80 eV and T-e \u3e= 20 eV during spheromak merging events after all plasma facing surfaces are cleaned with helium glow discharge conditioning. Transient electron heating is inferred from bursts on a four-channel soft x-ray array. The spheromaks are also characterized by a suite of magnetic probe arrays for magnetic structure B(r,t), and interferometry for n(e) . Finally, we are designing a new oblate, trapezoidal flux conserver for FRC studies. Equilibrium and dynamical simulations suggest that a tilt-stable, oblate FRC can be formed by spheromak merging in the new flux conserver

    Investigation of external refrigeration systems for long term cryogenic storage Final report

    Get PDF
    Data on external refrigeration systems for space storage of cryogens for long period

    Investigation of external refrigeration systems for long-term cryogenic storage

    Get PDF
    Evaluation of cryogenic refrigeration systems for space application

    Community acceptance and implementation of HIV prevention interventions for injection drug users

    Get PDF
    In 1997, the National Institutes of Health (NIH) reviewed evidence of the effectiveness of HIV prevention programs for injection drug users (IDUs) and recommended that three types ofinterventions be implemented to prevent transmission of HIV among IDUs: 1) community-based outreach, 2) expanded syringe access (including needle exchange programs [NEP] and pharmacy sales), and 3) drug treatment. Progress on increasing the acceptance and feasibility of implementing these programs has been made at the national level, but their implementation has been varied at the local level.Understanding the conditions under which communities accept and implement interventions can help guide effective strategies to foster the implementation of these interventions in areas where programs do not currently exist

    Bioelectronic DNA detection of human papillomaviruses using eSensor™: a model system for detection of multiple pathogens

    Get PDF
    BACKGROUND: We used human papillomaviruses (HPV) as a model system to evaluate the utility of a nucleic acid, hybridization-based bioelectronic DNA detection platform (eSensor™) in identifying multiple pathogens. METHODS: Two chips were spotted with capture probes consisting of DNA oligonucleotide sequences specific for HPV types. Electrically conductive signal probes were synthesized to be complementary to a distinct region of the amplified HPV target DNA. A portion of the HPV L1 region that was amplified by using consensus primers served as target DNA. The amplified target was mixed with a cocktail of signal probes and added to a cartridge containing a DNA chip to allow for hybridization with complementary capture probes. RESULTS: Two bioelectric chips were designed and successfully detected 86% of the HPV types contained in clinical samples. CONCLUSIONS: This model system demonstrates the potential of the eSensor platform for rapid and integrated detection of multiple pathogens

    DDFT calibration and investigation of an anisotropic phase-field crystal model

    Full text link
    The anisotropic phase-field crystal model recently proposed and used by Prieler et al. [J. Phys.: Condens. Matter 21, 464110 (2009)] is derived from microscopic density functional theory for anisotropic particles with fixed orientation. Further its morphology diagram is explored. In particular we investigated the influence of anisotropy and undercooling on the process of nucleation and microstructure formation from atomic to the microscale. To that end numerical simulations were performed varying those dimensionless parameters which represent anisotropy and undercooling in our anisotropic phase-field crystal (APFC) model. The results from these numerical simulations are summarized in terms of a morphology diagram of the stable state phase. These stable phases are also investigated with respect to their kinetics and characteristic morphological features.Comment: It contain 13 pages and total of 7 figure

    Area-level Socioeconomic Inequalities in the Use of Mammography Screening: A Multilevel Analysis of the Health of Houston Survey

    Get PDF
    An emerging literature reports that women who reside in socioeconomically deprived communities are less likely to adhere to mammography screening. This study explored associations between area-level socioeconomic measures and mammography screening among a racially and ethnically diverse sample of women in Texas
    • …
    corecore