15 research outputs found

    A survey for variable young stars with small telescopes: VIII — Properties of 1687 Gaia selected members in 21 nearby clusters

    Get PDF
    The Hunting Outbursting Young Stars (HOYS) project performs long-term, optical, multi- filter, high cadence monitoring of 25 nearby young clusters and star forming regions. Utilising Gaia DR3 data we have identified about 17000 potential young stellar members in 45 coherent astrometric groups in these fields. Twenty one of them are clear young groups or clusters of stars within one kiloparsec and they contain 9143 Gaia selected potential members. The cluster distances, proper motions and membership numbers are determined. We analyse long term ( 7 yr) V, R, and I-band light curves from HOYS for 1687 of the potential cluster members. One quarter of the stars are variable in all three optical filters, and two thirds of these have light curves that are symmetric around the mean. Light curves affected by obscuration from circumstellar materials are more common than those affected by accretion bursts, by a factor of 2 – 4. The variability fraction in the clusters ranges from 10 to almost 100 percent, and correlates positively with the fraction of stars with detectable inner disks, indicating that a lot of variability is driven by the disk. About one in six variables shows detectable periodicity, mostly caused by magnetic spots. Two thirds of the periodic variables with disk excess emission are slow rotators, and amongst the stars without disk excess two thirds are fast rotators – in agreement with rotation being slowed down by the presence of a disk

    A survey for variable young stars with small telescopes: IX - Evolution of spot properties on YSOs in IC 5070

    Get PDF
    We present spot properties on 32 periodic young stellar objects in IC 5070. Long term, ∼5 yr, light curves in the V, R, and I-bands are obtained through the HOYS (Hunting Outbursting Young Stars) citizen science project. These are dissected into six months long slices, with 3 months oversampling, to measure 234 sets of amplitudes in all filters. We fit 180 of these with reliable spot solutions. Two thirds of spot solutions are cold spots, the lowest is 2150 K below the stellar temperature. One third are warm spots that are above the stellar temperature by less than ∼2000 K. Cold and warm spots have maximum surface coverage values of 40 per cent, although only 16 per cent of warm spots are above 20 per cent surface coverage as opposed to 60 per cent of the cold spots. Warm spots are most likely caused by a combination of plages and low density accretion columns, most common on objects without inner disc excess emission in K − W2. Five small hot spot solutions have <3 percent coverage and are 3000 – 5000 K above the stellar temperature. These are attributed to accretion, and four of them occur on the same object. The majority of our objects are likely to be accreting. However, we observe very few accretion hot spots as either the accretion is not stable on our timescale or the photometry is dominated by other features. We do not identify cyclical spot behaviour on the targets. We additionally identify and discuss a number of objects that have interesting amplitudes, phase changes, or spot properties

    A survey for variable young stars with small telescopes – VIII. Properties of 1687 Gaia selected members in 21 nearby clusters

    Get PDF
    The Hunting Outbursting Young Stars (HOYS) project performs long-term, optical, multi-filter, high cadence monitoring of 25 nearby young clusters and star forming regions. Utilising Gaia DR3 data we have identified about 17000 potential young stellar members in 45 coherent astrometric groups in these fields. Twenty one of them are clear young groups or clusters of stars within one kiloparsec and they contain 9143 Gaia selected potential members. The cluster distances, proper motions and membership numbers are determined. We analyse long term (≈ 7 yr) V, R, and I-band light curves from HOYS for 1687 of the potential cluster members. One quarter of the stars are variable in all three optical filters, and two thirds of these have light curves that are symmetric around the mean. Light curves affected by obscuration from circumstellar materials are more common than those affected by accretion bursts, by a factor of 2 – 4. The variability fraction in the clusters ranges from 10 to almost 100 percent, and correlates positively with the fraction of stars with detectable inner disks, indicating that a lot of variability is driven by the disk. About one in six variables shows detectable periodicity, mostly caused by magnetic spots. Two thirds of the periodic variables with disk excess emission are slow rotators, and amongst the stars without disk excess two thirds are fast rotators – in agreement with rotation being slowed down by the presence of a disk

    Thermal Changes in the Hard Dental Tissue at Diode Laser Root Canal Treatment

    No full text
    The laser coagulation at the apical part of the root canal after vital extirpation is a proper method of preventing complications such as pain, bleeding, remaining vital pulp. The aim of the present survey is to register the thermal changes that occur on the tooth surfaces during laser treatment of the root canal after vital extirpation. An in vitro study of 30 extracted teeth has been conducted. The teeth have been prepared with ProTaper nickel-titanium machine tools and wiped dry. During the course of laser treatment of root canals with a diode laser DenLase temperatures, changes of the surface of the hard dental tissues have been recorded with infrared camera FLIR T330. The captured thermal images have been processed with software product Flir Reporter Pro 9. In conclusion, temperature changes in hard dental tissues at diode laser treatment of the root canal are biocompatible

    Diagnosis of Dentin Caries – Ultraviolet Fluorescence

    No full text
    The technology advance in recent years determines the need of construction of modern appliances for early diagnosis of dental caries, which are categorized by great precision, non-invasiveness, easy usage and wide availability. Such non-invasive and accurate tool for diagnostics of caries is Caries Detector (LED), Bulgarian product by “Optica Laser”. The detector emits a specific wavelength of near ultraviolet light, which causes fluorescence to porphyrins - metabolic products of the life cycle of caries-inducing bacteria. The purpose of the study is piloting a new diagnostic tool for detection and monitoring of caries excavation based on fluorescence - LED UV caries detector of company “Optica laser”. Subjected to examination by caries indicator dye and UV caries detector were sixty permanent teeth with deep dentine caries. Two methods were used to assess the dentin caries - UV fluorescence detector of “Optica Laser” and staining with caries indicator - dye (Sable ™ Seek®). It was found that among all sixty teeth, the fields, closed by margins of carious process overlap. Fifty-four of tested teeth has shown bigger field of images with staining method and six - smaller in comparison to the fluorescent method. Ultraviolet fLuorescence caries detector of “Optica Laser” company is affordable and easy applicable method for controlled excavation of dentine caries. The detector can be used in daily dental practice equally with other methods. The unit has a number of advantages - non-invasiveness, lack of interaction with tooth structures, speed, reliability, efficiency, predictability and repeatability of results

    Resection of the Tooth Apex with Diode Laser

    No full text
    An “in vitro” experimental study has been carried out on 70 extracted teeth. A laser resection of the root apex has been carried out with diode laser beam with a wavelength of - 810 ± 10 nm. Sequentially a radiation with increasing power has been applied, as follows: 1,3 W, 2W, 3W, 4W, 5W, 6W, 7W, in electro surgery mode. Successful resection of the tooth apex has been performed at: 3W; 4W; 5W; 6W and 7W power. It was established that when laser resected the tooth apex carbonizes

    Superluminous Devices Versus Low-Level Laser for Temporomandibular Disorders

    No full text
    The aim of this study is to compare the pain intensity reduction between the mean radiation doses per session of gallium-aluminum-arsenide (GaAIAs) laser with superluminous diodes (SLD) in four of the most common pain-related chronic temporomandibular disorders (TMD) - local myalgia, myofascial pain, myofascial pain with a referral, and arthralgia. This study was implemented on 124 patients with pain-related temporomandibular disorders according to the DC/TMD criteria. We applied trigger point oriented near-infrared laser (785 nm, 100 s, 8 J/cm2) and SLD cluster sessions (the cluster is composed of 49 SLDs with a combination of visible red (633 nm) and infrared (880 nm) diodes, 200 mW, 300 s, 8 J/cm2) for the temporomandibular joints and the affected muscles. Patients were evaluated at the start of the treatment, and after the 6th session of combined phototherapy. The pain intensity scores were measured according to the Visual Analogue Scale (VAS). Our results show that the most statistically manifested pain reduction is found for the SLD dose, р = 0,000118, followed by the overall dose (laser plus SLD); р = 0,001031, and the laser dose; р = 0,030942 (ANOVA dispersion analyses). Consequently, it can be concluded that myalgia is better treated through lower doses of red light compared to infrared laser doses because SLDs combine the prooxidative effect of photons with 633 nm wavelength, a large area of exposure, sufficient tissue penetration, and some positive warming thermal impact of the SLD clusters
    corecore