975 research outputs found
Resistive plate chambers for time-of-flight measurements
The applications of Resistive Plate Chambers (RPCs) have recently been
extended by the development of counters with time resolution below 100 ps sigma
for minimum ionising particles. Applications to HEP experiments have already
taken place and many further applications are under study. In this work we
address the operating principles of such counters along with some present
challenges, with emphasis on counter aging.Comment: Presented at "PSD6 - 6th International Conference on Position
Sensitive Detectors", 9-13 September 2002, Leicester, UK. Submitted to
Nuclear Instruments and Methods
High Resolution RPC's for Large TOF Systems
Here we report on a particular type of RPC that presents up to 99% efficiency
for minimum ionizing particles and a very sharp time resolution, below 50 ps
sigma in the most optimized conditions. Our 9 cm2 cells, made with glass and
metal electrodes that form accurately spaced gaps of a few hundred micrometers,
are operated at atmospheric pressure in non-flammable gases and can be
economically produced in large quantities, opening perspectives for the
construction of large area time of flight systems.Comment: 10 pages, 8 figure
Advances in the Development of Micropattern Gaseous Detectors with Resistive Electrodes
We describe the most recent efforts made by various groups in implementing
resistive electrodes in micropattern gaseous detectors with the aim to combine
in the same design the best features of RPCs (for the example, their robustness
and spark protection property) with the high granularity and thus the good
position resolution offered by microelectronic technology. In the stream of
this activity, we have recently developed two novel detectors with resistive
electrodes: one was based on resistive micromeshes and the second one is a MSGC
with resistive electrodes. We have demonstrated that the resistive meshes are a
convenient construction element for various designs of spark protective
detectors: RPCs type, GEM type and MICROMEGAS type. These new detectors enable
to considerably enhance the RPC and micropattern detectors applications since
they feature not only a high position resolution but also a relatively good
energy resolution (25-30 persent FWHM at 6 keV) and, if necessary, they can
operate in cascaded mode allowing the achievement of a high overall gas gain.
The main conclusion from these studies is that the implementation of resistive
electrodes in micropattern detectors makes them fully spark protected; on this
basis we consider this direction very promising
High Resolution Timing of MIPs with RPCs
Proposal of abstract for RPC99, Bari, Italy, 28-29 October 1999. RPCs made with glass and metal electrodes, forming accurately spaced gaps of a few hundred micrometres, have reached timing accuracies below 70 ps with efficiencies above 95This type of detector, operating at atmospheric pressure with non-flammable gases, seems well suited for large area TOF sytems, providing performances comparable to the existing scintillator-based TOF technology but with significantly lower price per channel.In this work we describe the principles of operation and the performance of several chamber configurations
Superior capsular reconstruction: current evidence and limits
The treatment of rotator cuff tears (RCTs) has evolved. Nonsurgical treatment is adequate for many patients; however, for those for whom surgical treatment is indicated, rotator cuff repair provides reliable pain relief and good functional results. However, massive and irreparable RCTs are a significant challenge for both patients and surgeons. Superior capsular reconstruction (SCR) has become increasingly popular in recent years. It works by passively restoring the superior restriction of the humeral head, thus restoring the pair of forces and improving the kinematics of the glenohumeral joint. Early clinical results using fascia lata (FL) autograft were promising in terms of pain relief and function. The procedure has evolved, and some authors have suggested that FL autografts could be replaced by other methods. However, surgical techniques for SCR are highly variable, and patient indications remain undefined. There are concerns that the available scientific evidence does not support the popularity of the procedure. This review aimed to critically evaluate the biomechanics, indications, procedural considerations, and clinical outcomes associated with the SCR procedure.info:eu-repo/semantics/publishedVersio
Demonstration of new possibilities of multilayer technology on resistive microstrip/ microdot detectors
The first successful attempts to optimize the electric field in Resistive
Microstrip Gas Chamber and resistive microdot detectors using additional field
shaping strips located inside the detector substrate are describedComment: Presented at the RD-51 mmini week, CERN, June 201
On the physics and technology of gaseous particle detectors
Despite an already long and fruitful history, gaseous elementary-particle
detectors remain today an important mainstay of high-energy and nuclear physics
experiments and of radiation detection in general. In here we briefly describe
some of the gaseous detector's main technologies and applications, along with
some unsolved gas-discharge physics aspects of practical relevance.Comment: Submitted to Plasma Sources in Science and Technolog
- …