4,440 research outputs found

    Limiting Behaviour of the Mean Residual Life

    Full text link
    In survival or reliability studies, the mean residual life or life expectancy is an important characteristic of the model. Here, we study the limiting behaviour of the mean residual life, and derive an asymptotic expansion which can be used to obtain a good approximation for large values of the time variable. The asymptotic expansion is valid for a quite general class of failure rate distributions--perhaps the largest class that can be expected given that the terms depend only on the failure rate and its derivatives.Comment: 19 page

    Role of combined DWIBS/3D-CE-T1w whole-body MRI in tumor staging: Comparison with PET-CT

    Get PDF
    Objectives: To assess the diagnostic performance of whole-body magnetic resonance imaging (WB-MRI) by diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in malignant tumor detection and the potential diagnostic advantages in generating fused DWIBS/3D-contrast enhanced T1w (3D-CE-T1w) images. Methods: 45 cancer patients underwent 18F-FDG PET-CT and WB-MRI for staging purpose. Fused DWIBS/3D-CE T1w images were generated off-line. 3D-CE-T1w, DWIBS images alone and fused with 3D-CE T1w were compared by two readers groups for detection of primary diseases and local/distant metastases. Diagnostic performance between the three WB-MRI data sets was assessed using receiver operating characteristic (ROC) curve analysis. Imaging exams and histopathological results were used as standard of references. Results: Areas under the ROC curves of DWIBS vs. 3D-CE-T1w vs. both sequences in fused fashion were 0.97, 0.978, and 1.00, respectively. The diagnostic performance in tumor detection of fused DWIBS/3DCE- T1w images were statistically superior to DWIBS (p < 0.001) and 3D-CE-T1w (p ≀ 0.002); while the difference between DWIBS and 3D-CE-T1w did not show statistical significance difference. Detection rates of malignancy did not differ between WB-MRI with DWIBS and 18F-FDG PET-CT. Conclusion: WB-MRI with DWIBS is to be considered as alternative tool to conventional whole-body methods for tumor staging and during follow-up in cancer patients

    A study of gas contaminants and interaction with materials in RPC closed loop systems

    Full text link
    Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants

    Patient skin dose measurements using a cable free system MOSFETs based in fluoroscopically guided percutaneous vertebroplasty, percutaneous disc decompression, radiofrequency medial branch neurolysis, and endovascular critical limb ischemia

    Get PDF
    The purpose of this work has been to dosimetrically investigate four fluoroscopically guided interventions: the percutaneous vertebroplasty (PVP), the percutaneous disc decompression (PDD), the radiofrequency medial branch neurolysis (RF) (hereafter named spine procedures), and the endovascular treatment for the critical limb ischemia (CLI). The X-ray equipment used was a Philips Integris Allura Xper FD20 imaging system provided with a dose-area product (DAP) meter. The parameters investigated were: maximum skin dose (MSD), air kerma (Ka,r), DAP, and fluoroscopy time (FT). In order to measure the maximum skin dose, we employed a system based on MOSFET detectors. Before using the system on patients, a calibration factor Fc and correction factors for energy (CkV) and field size (CFD) dependence were determined. Ka,r, DAP, and FT were extrapolated from the X-ray equipment. The analysis was carried out on 40 patients, 10 for each procedure. The average fluoroscopy time and DAP values were compared with the reference levels (RLs) proposed in literature. Finally, the correlations between MSD, FT, Ka,r, and DAP values, as well as between DAP and FT values, were studied in terms of Pearson's product-moment coefficients for spine procedures only. An Fc value of 0.20 and a very low dependence of CFD on field size were found. A third-order polynomial function was chosen for CkV. The mean values of MSD ranged from 2.3 to 10.8cGy for CLI and PVP, respectively. For these procedures, the DAP and FT values were within the proposed RL values. The statistical analysis showed little correlation between the investigated parameters. The interventional procedures investigated were found to be both safe with regard to deterministic effects and optimized for stochastic ones. In the spine procedures, the observed correlations indicated that the estimation of MSD from Ka,r or DAP was not accurate and a direct measure of MSD is therefore recommended

    Sustainable and green persulfate-based chemiluminescent method for on-site estimation of chemical oxygen demand in waters

    Get PDF
    The standard method for estimating the chemical oxygen demand (COD) of water bodies uses dichromate as the main oxidant, a chemical agent whose use has been restricted in the European Union since 2017. This method is hazardous, time-consuming, and burdensome to adapt to on-site measurements. As an alternative and following the current trends of sustainable and green chemistry, a method using the less toxic reagent sodium persulfate as the oxidizing agent has been developed. In this method an excess of persulfate, activated through heating in an alkaline solution, oxidizes the chemically degradable organic fraction through a 2-step radical mechanism. The remaining persulfate is evaluated by chemiluminescence (CL) using luminol and a portable charge-coupled device (CCD) camera. The method provided quantitative recoveries and a sample throughput of &gt;60 samples h. It was validated in river water samples by comparison of COD estimations with the standard dichromate method (R = 0.973, p &lt; 0.05) and with a UV–Vis permanganate-based method (R = 0.9998, p &lt; 0.05), the latter being also used for drinking waters. The proposed method is a sustainable and green alternative to the previous used methods. Overall, the method using activated persulfate is suitable for use as COD quantitation/screening tool in surface waters. Considering that its main components are portable, it can be ultimately adapted for in situ analysis at the point of need

    Effects of the antioxidant crocin on frozen-thawed buffalo (Bubalus bubalis) sperm

    Get PDF
    This work aimed to evaluate the effect of crocin on frozen-thawed sperm quality in buffalo. Spermatozoa were incubated in Tyrode’s Albumin Lactate Pyruvate medium supplemented with 0, 0.5, 1, and 2 mM crocin for 2 h. Sperm motility was evaluated by phase-contrast microscopy, viability and acrosome integrity by Trypan blue Giemsa staining, and membrane functional integrity by the hypoosmotic swelling test. The DNA fragmentation was evaluated by Tunel and ROS levels by spectrofluorometric analysis. The treatment with 2 mM of crocin increased (P &lt;.05) sperm membrane functional integrity compared to the control group (59.1 ± 1.6 vs 53.3 ± 1.5) and reduced sperm DNA fragmentation, compared to the other groups (11.3 ± 1.1, 13.3 ± 1.2, 13.6 ± 1.2 and 6.0 ± 0.7, respectively in 0, 0.5, 1 and 2 mM crocin; P &lt;.01). Finally, a dose-dependent decrease (P &lt;.01) in superoxide anion production in the presence of crocin was observed, as indicated by Dihydroethidium values (922.6 ± 13.0, 596.8 ± 7.4, 498.9 ± 5.3 and 421.4 ± 5.0 a.u., respectively in 0, 0.5, 1 and 2 mM crocin; P &lt;.01). The results of this study demonstrated a positive effect of 2 mM crocin on frozen-thawed buffalo sperm, as indicated by the improvement of sperm membrane integrity and the reduction of DNA fragmentation and ROS levels.Highlights Crocin improves buffalo sperm quality. Crocin improves sperm membrane integrity and reduces DNA fragmentation. Crocin decreases oxidative stress in buffalo sperm

    UGA’s Green Infrastructure Plan: Student Envisioned Plans to Improve Ecosystem Services on Campus

    Get PDF
    Proceedings of the 2011 Georgia Water Resources Conference, April 11, 12, and 13, 2011, Athens, Georgia.Graduate students from the “Nature and Sustainability” studio course at UGA’s College of Environment and Design created Green Infrastructure Plans for UGA’s Campus. Objectives of this service learning project included gathering inventory information, analyzing existing conditions, garnering stakeholder input and crafting plans at two scales. Students individually prepared campus wide plans, and then created site plans for a specific area. These proposed interventions were based on creating or enhancing a network of linkages and hubs (corridors and patches), otherwise known as Green Infrastructure, which supports ecosystem services such as water and nutrient cycling. Unfortunately, legacy land use and substantial impermeable area on campus hinders ecosystem function. In order to reverse these trends to approach a more sustainable trajectory, students sought to preserve, enhance and/or restore critical ecosystem services. This planning process may inform future planning efforts undertaken by the Office of University Architects to improve the green infrastructure of campus and further sustainability goals.Sponsored by: Georgia Environmental Protection Division U.S. Geological Survey, Georgia Water Science Center U.S. Department of Agriculture, Natural Resources Conservation Service Georgia Institute of Technology, Georgia Water Resources Institute The University of Georgia, Water Resources FacultyThis book was published by Warnell School of Forestry and Natural Resources, The University of Georgia, Athens, Georgia 30602-2152. The views and statements advanced in this publication are solely those of the authors and do not represent official views or policies of The University of Georgia, the U.S. Geological Survey, the Georgia Water Research Institute as authorized by the Water Research Institutes Authorization Act of 1990 (P.L. 101-307) or the other conference sponsors

    Approaching stimuli bias attention in numerical space

    Get PDF
    Increasing evidence suggests that common mechanisms underlie the direction of attention in physical space and numerical space, along the mental number line. The small leftward bias (pseudoneglect) found on paper-and-pencil line bisection is also observed when participants ‘bisect’ number pairs, estimating (without calculating) the number midway between two others. Here we investigated the effect of stimulus motion on attention in numerical space. A two-frame apparent motion paradigm manipulating stimulus size was used to produce the impression that pairs of numbers were approaching (size increase from first to second frame), receding (size decrease), or not moving (no size change). The magnitude of pseudoneglect increased for approaching numbers, even when the final stimulus size was held constant. This result is consistent with previous findings that pseudoneglect in numerical space (as in physical space) increases as stimuli are brought closer to the participant. It also suggests that the perception of stimulus motion modulates attention over the mental number line and provides further support for a connection between the neural representations of physical space and number
    • 

    corecore