25 research outputs found
Effect of the Output of the System in Signal Detection
We analyze the consequences that the choice of the output of the system has
in the efficiency of signal detection. It is shown that the signal and the
signal-to-noise ratio (SNR), used to characterize the phenomenon of stochastic
resonance, strongly depend on the form of the output. In particular, the SNR
may be enhanced for an adequate output.Comment: 4 pages, RevTex, 6 PostScript figure
The effect of ambient temperature on gross-efficiency in cycling
Time-trial performance deteriorates in the heat. This might potentially be the result of a temperature-induced decrease in gross-efficiency (GE). The effect of high ambient temperature on GE during cycling will be studied, with the intent of determining if a heat-induced change in GE could account for the performance decrements in time trial exercise found in literature. Ten well-trained male cyclists performed 20-min cycle ergometer exercise at 60%
\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}\end{document} (power output at which VO2max was attained) in a thermo-neutral climate (N) of 15.6 ± 0.3°C, 20.0 ± 10.3% RH and a hot climate (H) of 35.5 ± 0.5°C, 15.5 ± 3.2% RH. GE was calculated based on VO2 and RER. Skin temperature (Tsk), rectal temperature (Tre) and muscle temperature (Tm) (only in H) were measured. GE was 0.9% lower in H compared to N (19.6 ± 1.1% vs. 20.5 ± 1.4%) (P < 0.05). Tsk (33.4 ± 0.6°C vs. 27.7 ± 0.7°C) and Tre (37.4 ± 0.6°C vs. 37.0 ± 0.6°C) were significantly higher in H. Tm was 38.7 ± 1.1°C in H. GE was lower in heat. Tm was not high enough to make mitochondrial leakage a likely explanation for the observed reduced GE. Neither was the increased Tre. Increased skin blood flow might have had a stealing effect on muscular blood flow, and thus impacted GE. Cycling model simulations showed, that the decrease in GE could account for half of the performance decrement. GE decreased in heat to a degree that could explain at least part of the well-established performance decrements in the heat
Criteria document carbon tetrachloride
Dit rapport bevat een systematisch overzicht en een kritische evaluatie van de belangrijkste gegevens over de prioritaire stof tetrachloormethaan. Het dient ter onderbouwing van een kwaliteitseis voor de buitenlucht van deze stof.DGMH/L