1,299 research outputs found

    Design Considerations Regarding Ellipsoidal Mirror Based Reflectometers

    Get PDF
    Hemi-ellipsoidal mirrors are used in reflection-based measurements due to their ability to collect light scattered from one focal point at the other. In this paper, a radiometric model of this energy transfer is derived for arbitrary mirror and detector geometries. This model is used to examine the imaging characteristics of the mirror away from focus for both diffuse and specular light. The radiometric model is applied to several detector geometries for measuring the Directional Hemispherical Reflectance for both diffuse and specular samples. The angular absorption characteristics of the detector are then applied to the measurement to address measurement accuracy for diffuse and specular samples. Examining different detector configurations shows the effectiveness of flat detectors at angles ranging from normal to 50°, and that multifaceted detectors can function from normal incidence to grazing angles

    Bidirectional Scatter Measurements of a Guided-mode Resonant Filter Photonic Crystal Structure

    Get PDF
    This work investigates the Bidirectional Scatter Distribution Function (BSDF) at incident angles other than normal and at 544-nm wavelength of a Guided Mode Resonance Filter (GMRF) Photonic Crystal (PC) structure designed for normally incident light at 532 nm. Strong out-coupling of PC diffraction orders into both the transmitted and reflected hemispheres was observed specifically at a 25.7° incidence angle, which we attribute to this incident angle/wavelength pair being a good match to the ( ± 1, 0) PC grating mode. BSDF measurements at incident angles of 15° and 35° also displayed some out-coupled diffraction, though much lower in magnitude, and are also attributed to being a weaker match to the ( ± 1, 0) PC grating mode. Three-dimensional finite-difference time-domain Maxwell\u27s equation simulations demonstrate that since this GMRF was designed for complete destructive interference of the transmitted light upon normal incidence, stronger out-coupling of the diffraction is expected for modal solutions as the angle of incidence increases. © 2012 Optical Society of America

    Optical Characterization of Silver Nanorod Thin Films Grown Using Oblique Angle Deposition

    Get PDF
    Nanorods are metamaterial structures that have been shown to have wide application, ranging from biomedical uses to photovoltaic materials. These materials have unique optical characteristics. In this paper, two silver (Ag) nanorod thin-film samples are created using Glancing Angle Deposition (GLAD) at both near-room temperature (~300 K) and cryogenic temperature (~100 K). Generalized ellipsometry is used to measure the optical constants of the samples. The strong difference between the optical constants of the constituent materials and those of these thin films shows that the characteristics of the samples are due to how their metamaterial structures are defined. The principle optical axes of the films align well with the morphological characteristics of the nanostructures. The axis with the greatest index of refraction remains aligned to the principle axes but shifts orientation with respect to morphological characteristics between samples. Experimental results show differences in both magnitude and characteristics of the nanorod indexes. Reflectance and transmittance measurements are performed to extract absorptance data. The room temperature deposited sample shows a higher overall absorptance, while the cryogenic sample shows a clear orientation-dependent absorptance. Polarization data is analyzed to show that the 100 K thin film exhibits polarization-dependent absorptance, while the 300 K sample’s absorptance has a strong orientation dependence

    Optical Characterization of Silver Nanorod Thin Films Grown Using Oblique Angle Deposition

    Get PDF
    Nanorods are metamaterial structures that have been shown to have wide application, ranging from biomedical uses to photovoltaic materials. These materials have unique optical characteristics. In this paper, two silver (Ag) nanorod thin-film samples are created using Glancing Angle Deposition (GLAD) at both near-room temperature (~300 K) and cryogenic temperature (~100 K). Generalized ellipsometry is used to measure the optical constants of the samples. The strong difference between the optical constants of the constituent materials and those of these thin films shows that the characteristics of the samples are due to how their metamaterial structures are defined. The principle optical axes of the films align well with the morphological characteristics of the nanostructures. The axis with the greatest index of refraction remains aligned to the principle axes but shifts orientation with respect to morphological characteristics between samples. Experimental results show differences in both magnitude and characteristics of the nanorod indexes. Reflectance and transmittance measurements are performed to extract absorptance data. The room temperature deposited sample shows a higher overall absorptance, while the cryogenic sample shows a clear orientation-dependent absorptance. Polarization data is analyzed to show that the 100 K thin film exhibits polarization-dependent absorptance, while the 300 K sample’s absorptance has a strong orientation dependence

    Discrete and continuum phenotype-structured models for the evolution of cancer cell populations under chemotherapy

    Get PDF
    We present a stochastic individual-based model for the phenotypic evolution of cancer cell populations under chemotherapy. In particular, we consider the case of combination cancer therapy whereby a chemotherapeutic agent is administered as the primary treatment and an epigenetic drug is used as an adjuvant treatment. The cell population is structured by the expression level of a gene that controls cell proliferation and chemoresistance. In order to obtain an analytical description of evolutionary dynamics, we formally derive a deterministic continuum counterpart of this discrete model, which is given by a nonlocal parabolic equation for the cell population density function. Integrating computational simulations of the individual-based model with analysis of the corresponding continuum model, we perform a complete exploration of the model parameter space. We show that harsher environmental conditions and higher probabilities of spontaneous epimutation can lead to more effective chemotherapy, and we demonstrate the existence of an inverse relationship between the efficacy of the epigenetic drug and the probability of spontaneous epimutation. Taken together, the outcomes of the model provide theoretical ground for the development of anticancer protocols that use lower concentrations of chemotherapeutic agents in combination with epigenetic drugs capable of promoting the re-expression of epigenetically regulated genes

    Optimizing Switching of Non-linear Properties with Hyperbolic Metamaterials

    Get PDF
    Hyperbolic metamaterials have been demonstrated to have special potential in their linear response, but the extent of their non-linear response has not been extensively modeled or measured. In this work, novel non-linear behavior of an ITO/SiO2 layered hyperbolic metamaterial is modeled and experimentally confirmed, specifically a change in the sign of the non-linear absorption with intensity. This behavior is tunable and can be achieved with a simple one-dimensional layered design. Fabrication was performed with physical vapor deposition, and measurements were conducted using the Z-scan technique. Potential applications include tunable optical switches, optical limiters, and tunable components of laser sources

    Exercise mode in heart failure: A systematic review and meta-analysis.

    Get PDF
    Background: Optimising exercise prescription in heart failure (HF) with a preserved (HFpEF) or reduced (HFrEF) ejection fraction is clinically important. As such, the aim of this meta-analysis was to compare traditional moderate intensity training (MIT) against combined aerobic and resistance training (CT) and high intensity interval training (HIIT) for improving aerobic capacity (VO2), as well as other clinically relevant parameters. Methods: A comprehensive systematic search was performed to identify randomised controlled trials published between 1990 and May 2021. Research trials reporting the effects of MIT against CT or HIIT on peak VO2 in HFpEF or HFrEF were considered. Left-ventricular ejection fraction (LVEF) and various markers of diastolic function were also analysed. Results: 17 studies were included in the final analysis, 4 of which compared MIT against CT and 13 compared MIT against HIIT. There were no significant differences between MIT and CT for peak VO2 (WMD:0.521ml·min-1·kg-1, [95% CI] =-0.7-1.8, Pfixed=0.412) or LVEF (WMD:-1.129 %, [95%CI] =-3.8-1.5,Pfixed=0.408). However, HIIT was significantly more effective than MIT at improving peak VO2 (WMD:1.62 ml·min-1·kg-1, [95%CI] =0.6-2.6,Prandom=0.002) and LVEF (WMD:3.24 %, [95%CI] =1.7-4.8,Prandom<0.001) in HF patients. When dichotomized by HF phenotype, HIIT remained significantly more effective than MIT in all analyses except for peak VO2 in HFpEF. Conclusions: HIIT is significantly more effective than MIT for improving peak VO2 and LVEF in HF patients. With the exception of peak VO2 in HFpEF, these findings remain consistent in both phenotypes. Separately, there is no difference in peak VO2 and LVEF change following MIT or CT, suggesting the addition of resistance exercise does not inhibit aerobic adaptations in HF
    • …
    corecore