64 research outputs found
Lack of Neointimal Proliferation After Implantation of Sirolimus-Coated Stents in Human Coronary Arteries: A Quantitative Coronary Angiography and Three-Dimensional Intravascular Ultrasound Study
BACKGROUND: Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS: Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=15). All stents were successfully delivered, and patients were discharged without clinical complications. Independent core laboratories analyzed angiographic and 3D volumetric intravascular ultrasound data (immediately after procedure and at 4-month follow-up). Eight-month clinical follow-up was obtained for all patients. There was minimal neointimal hyperplasia in both groups (11.0+/-3.0% in the SR group and 10.4+/-3.0% in the FR group, P:=NS) by ultrasound and quantitative coronary angiography (in-stent late loss, 0.09+/-0.3 mm [SR] and -0.02+/-0.3 mm [FR]; in-lesion late loss, 0.16+/-0.3 mm [SR] and -0.1+/-0.3 mm [FR]). No in-stent or edge restenosis (diameter stenosis >or=50%) was observed. No major clinical events (stent thrombosis, repeat revascularization, myocardial infarction, or death) had occurred by 8 months. CONCLUSIONS: The implantation of sirolimus-coated BX Velocity stents is feasible and safe and elicits minimal neointimal proliferation. Additional placebo-controlled trials are required to confirm these promising results
The importance of presynaptic beta receptors in Raynaud's disease
Abstract
The purpose of the present study was to investigate the effect of atenolol, a β1-selective blocker, along with flunarizine, a calcium antagonist, in the management of Raynaud's disease. Forty patients with Raynaud's disease were randomized into a trial in which atenolol (50 mg daily) was given with flunarizine (10 mg daily). During the trial all patients were subjected to finger photoplethysmography and were given a diary to note daily the number and duration of the crises and presence or absence of pain and paresthesia. The association of atenolol with flunarizine caused an 80% reduction in the number of vasospastic crises, a significant increase (p < 0.001) in the photoplethysmographic wave amplitude, and complete disappearance of pain and paresthesia. These results were not observed in patients treated with a placebo. Flunarizine reinforces the action of atenolol in causing a decrease in vasoconstriction in patients with Raynaud's disease, as observed previously by us, in that it acts directly on the β-presynaptic receptors or on the calcium slow channels connected to the β-receptors. The present study confirms that the principal role in the physiopathologic progression of Raynaud's disease seems to be played by a modification of the β-presynaptic receptors in the nerve endings of the peripheral vessels
Estudo prospectivo e randomizado de pacientes tratados com e sem stents revestidos com carbeto de silÃcio amorfo para a prevenção da reestenose coronariana. Avaliação ultra-sonográfica
OBJETIVO: A reestenose intra-stent é a maior limitação das intervenções coronárias percutâneas. O carbeto de silÃcio amorfo (SiC-a), substância antitrombótica e antiinflamatória capaz de reduzir a deposição de fibrina, plaquetas e leucócitos sobre o stent, apresenta potencial de prevenir a hiperplasia neo-intimal e a reestenose. MÉTODOS: Estudo prospectivo, randomizado e tipo rótulo aberto comparando pacientes com doença coronariana tratados com e sem stents revestidos com o SiC-a, utilizando a angiografia quantitativa e o ultra-som intracoronário. Foram incluÃdos 100 pacientes (50 em cada grupo) a fim de mensurar o volume de hiperplasia neo-intimal intra-stent/extremidades. Como os stents comparados apresentavam extensões diferentes, o volume de hiperplasia foi analisado em valores absolutos (por paciente) e relativos (por milÃmetro de extensão do stent). Avaliaram-se ainda os eventos cardÃacos maiores e os resultados da angiografia quantitativa. RESULTADOS: Os grupos apresentaram caracterÃsticas de base semelhantes. Todos os pacientes foram tratados com sucesso. No 6° mês de evolução foram reestudados 94% dos casos dos dois grupos, obtendo-se ultra-som em 92%. O volume de hiperplasia neo-intimal absoluto foi significativamente maior nos tratados com os stents revestidos (51.2 DP 18.8 mm³ vs 41.9 DP 16.4 mm³; p=0.014), porém o relativo foi semelhante (2.9 DP 1.0 mm³/mm stent vs 2.5 DP 0.9 mm³/mm stent; p=0.108). A obstrução volumétrica da luz também foi similar (36.4 DP 11.1% vs 37.9 DP 10.9%; p=0.505). O diâmetro mÃnimo da luz (1.9 DP 0.7 mm vs 1.8 DO 0.6 mm; p=0.552), a reestenose (19.1% vs 17%; p>0.999) e a revascularização do vaso-alvo (16% vs 14%; p>0.999) não diferiram. CONCLUSÃO: Os stents revestidos apresentaram resultados clÃnicos, angiográficos e ultra-sonográficos similares aos controles
- …