2,818 research outputs found
SONTRACâa scintillating plastic fiber tracking detector for neutron and proton imaging spectroscopy
SONTRAC (SOlar Neutron TRACking imager and spectrometer) is a conceptual instrument intended to measure the energy and incident direction of 20â150 MeV neutrons produced in solar flares. The intense neutron background in a low-Earth orbit requires that imaging techniques be employed to maximize an instrumentâs signal-to-noise ratio. The instrument is comprised of mutually perpendicular, alternating layers of parallel, scintillating, plastic fibers that are viewed by optoelectronic devices. Two stereoscopic views of recoil proton tracks are necessary to determine the incident neutronâs direction and energy. The instrument can also be used as a powerful energetic proton imager. Data from a fully functional 3-d prototype are presented. Early results indicate that the instrumentâs neutron energy resolution is approximately 10% with the neutron incident direction determined to within a few degrees
Recent laboratory tests of a hard x-ray solar flare polarimeter
We report on the development of a Compton scatter polarimeter for measuring the linear polarization of hard X-rays (50 - 300 keV) from solar flares. Such measurements would be useful for studying the directivity (or beaming) of the electrons that are accelerated in solar flares. We initially used a simple prototype polarimeter to successfully demonstrate the reliability of our Monte Carlo simulation code and to demonstrate our ability to generate a polarized photon source in the lab. We have recently fabricated a science model based on a modular design concept that places a self-contained polarimeter module on the front-end of a 5-inch position- sensitive PMT (PSPMT). The PSPMT is used to determine the Compton interaction location within an annular array of small plastic scintillator elements. Some of the photons that scatter within the plastic scintillator array are subsequently absorbed by a small centrally-located array of CsI(Tl) crystals that is read out by an independent multi-anode PMT. The independence of the two PMT readout schemes provides appropriate timing information for event triggering. We are currently testing this new polarimeter design in the laboratory to evaluate the performance characteristics of this design. Here we present the initial results from these laboratory tests. The modular nature of this design lends itself toward its accommodation on a balloon or spacecraft platform. A small array of such modules can provide a minimum detectable polarization (MDP) of less than 1% in the integrated 50 - 300 keV energy range for X-class solar flares
COBRA Subsidies for Laid-Off Workers: An Initial Report Card
Reviews the implementation of the government subsidy of COBRA health insurance premiums for laid-off workers in the 2009 stimulus package and its effects on COBRA enrollment and medical spending. Considers policy implications for access and affordability
Federal Subsidy for Laid-Off Workers' Health Insurance: A First Year's Report Card for the New COBRA Premium Assistance
Analyzes how the subsidy for laid-off workers' costs to continue their health coverage, included in the 2009 stimulus bill, affected enrollment. Considers determining factors, implications of health reform for extending the subsidy, and lessons learned
The Development of GRAPE, a Gamma Ray Polarimeter Experiment
The measurement of hard Xâray polarization in Îłâray bursts (GRBs) would add yet another piece of information in our effort to resolve the true nature of these enigmatic objects. Here we report on the development of a dedicated polarimeter design with a relatively large FoV that is capable of studying hard Xâray polarization (50â300 keV) from GRBs. This compact design, based on the use of a large area positionâsensitive PMT (PSPMT), is referred to as GRAPE (GammaâRAy Polarimeter Experiment). The feature of GRAPE that is especially attractive for studies of GRBs is the significant offâaxis polarization response (at angles greater than 60°). For an array of GRAPE modules, current sensitivity estimates give minimum detectable polarization (MDP) levels of a few percent for the brightest GRBs
Hard x-ray polarimeter for gamma-ray bursts and solar flares
We report on the development of a dedicated polarimeter design that is capable of studying the linear polarization of hard X-rays (50-300 keV) from gamma-ray bursts and solar flares. This compact design, based on the use of a large area position-sensitive PMT (PSPMT), is referred to as GRAPE (Gamma-RAy Polarimeter Experiment). The PSPMT is used to determine the Compton interaction location within an array of small plastic scintillator elements. Some of the photons that scatter within the plastic scintillator array are subsequently absorbed by a small centrally-located array of CsI(Tl) crystals that is read out by an independent multi-anode PMT. One feature of GRAPE that is especially attractive for studies of gamma-ray bursts is the significant off-axis response (at angles \u3e 60 degrees). The modular nature of this design lends itself toward its accomodation on a balloon or spacecraft platform. For an array of GRAPE modules, sensitivity levels below a few percent can be achieved for both gamma-ray bursts and solar flares. Here we report on the latest results from the testing of a laboratory science model
Dedicated polarimeter design for hard x-ray and soft gamma-ray astronomy
We have developed a modular design for a hard X-ray and soft gamma-ray polrimeter that we call GRAPE (Gamma RAy Polarimeter Experiment). Optimized for the energy range of 50-300 keV, the GRAPE design is a Compton polarimeter based on the use of an array of plastic scintillator scattering elements in conjunction with a centrally positioned high-Z calorimeter detector. Here we shall review the results from a laboratory model of the baseline GRAPE design. The baseline design uses a 5-inch diameter position sensitive PMT (PSPMT) for readout of the plastic scintillator array and a small array of CsI detectors for measurement of the scattered photon. An improved design, based on the use of large area multi-anode PMTs (MAPMTs), is also discussed along with plans for laboratory testing of a prototype. An array of GRAPE modules could be used as the basis for a dedicated science mission, either on a long duration balloon or on an orbital mission. With a large effective FoV, a non-imaging GRAPE mission would be ideal for studying polarization in transient sources (gamma ray bursts and solar flares). It may also prove useful for studying periodically varying sources, such as pulsars. An imaging system would improve the sensitivity of the polarization measurements for transient and periodic sources and may also permit the measurement of polarization in steady-state sources
Using LaX scintillator in a new low-background Compton telescope
The ability of Compton telescopes to perform imaging and spectroscopy in space depends directly on the speed and energy resolution of the calorimeter detectors in the telescope. The calorimeter detectors flown on space-borne or balloon-borne Compton telescopes have included NaI(Tl), CsI(Na), HPGe and liquid organic scintillator. By employing LaX scintillators for the calorimeter, one can take advantage of the unique speed and resolving power of the material to improve the instrument sensitivity and simultaneously enhance its spectroscopic performance and thus its imaging performance. We present a concept for a space-borne Compton telescope that employs LaX as a calorimeter and estimate the improvement in sensitivity over past realizations of Compton telescopes. With some preliminary laboratory measurements, we estimate that in key energy bands, typically corrupted with neutron-induced internal nuclear emissions, this design enjoys a twenty-fold improvement in background rejection
A Compton telescope for remote location and identification of radioactive material
The spare detectors from NASA Compton Gamma-Ray Observatory COMPTEL instrument have been reconfigured to demonstrate the capability at ground level to remotely locate and identify sources of g radiation or the movement of material that might shield Îł-ray sources. The Gamma-Ray Experimental Telescope Assembly (GRETA) employs two 28 cm diameter scintillation detectors separated by 81 cm: one 8.5 cm thick liquid scintillator detector and one 7.5 cm thick NaI(Tl) detector. The assembly electronics and real-time data acquisition system measures the energy deposits and time-of- flight for each coincident detection and compiles histograms of total energy and incident angle as computed using the kinematics of Compton scattering. The GRETA field of view is a cone with full angle approximately 120°. The sensitive energy range is 0.3 to 2.6 MeV. Energy resolution is ~10% FWHM. The angular resolution, ~19° in the simplified configuration tested, will improve to better than 5° with well-defined enhancements to the data acquisition hardware and data analysis routines. When operated in the mode that was used in space, the instrument is capable of measuring and imaging up to 30 MeV with an angular resolution of 1.5°. The response of the instrument was mapped in the laboratory with 14 Ci 22Na source 3 m from the instrument. Later, we conducted demonstrations under two measurement scenarios. In one, the remotely located instrument observed an increase of background radiation counts at 1.4 MeV when a large amount of lead was removed from a building and a corresponding decrease when the lead was replaced. In the other scenario, the location and isotope-identifying energy spectrum of a 500 ÎŒCi137Cs source 3-5 m from the instrument with two intervening walls was determined in less than one minute. We report details of the instrument design and these measurements
- âŠ