1,590 research outputs found

    Between Constraints and Coercion. Marriage and Social Reproduction in Northern and Central Italy, 18th-19th Centuries

    Get PDF
    In this paper we review the main theories of household and marriage systems, highlighting their inability to account for the astonishing variety of family and marriage patterns that characterized modern Italy. We propose a new interpretative framework, where social reproduction is given pride of place as the main factor shaping marital behavior and household formation in the past. We test our theory analyzing five populations in northern and central Italy, characterized by different ecological, economic, and social conditions. We use an event history analysis approach to model the timing of marriage in the populations under study. The results confirm that coercion mattered much more than Malthusian economic constraints. We conclude suggesting a more general application of our approach to the study of marital behavior, family formation, and residential patterns in the past

    Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: A literature review

    Get PDF
    Objectives: This paper aimed to provide a literature review of the mechanical and biological properties of zirconia-reinforced lithium silicate glass-ceramics (ZLS) in Computer-aided design / Computer-aided manufacturing (CAD/CAM) systems. Data/Sources: An extensive search of the literature for papers related to ZLS was made on the databases of PubMed/Medline, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The papers were selected by 3 independent calibrated reviewers. Study selection: The search strategy produced 937 records. After the removal of duplicates and the exclusion of papers that did not meet the inclusion criteria, 71 papers were included. Conclusions: After reviewing the included records, it was found that two types of ZLS (Vita Suprinity PC; Vita Zahnfabrik and Celtra Duo; Dentsply Sirona) are nowadays available on the market for CAD/CAM systems, similar in their chemical composition, microstructure, and biological-mechanical properties. ZLS is reported to be a biocompatible material, whose fracture resistance can withstand physiological chewing loads. The firing process influences the improvements of strength and fatigue failure load, with a volumetric shrinkage. To date, ZLS can be considered a viable alternative to other glass-ceramics for fixed single restorations. Clinical Significance:. As to biocompatibility and mechanical properties of ZLS, data are still scarce, often controversial and limited to short-term observational periods. These promising ceramics require further in vitro/in vivo studies to accurately define mechanical and biological properties, mainly in the long-term performance of restorations produced with such materials

    The occlusal precision of milled versus printed provisional crowns

    Get PDF
    Objectives: The aim of this study was to compare the occlusal precision of computer-aided-design/ computer-assisted-manufacturing (CAD/CAM) milled versus 3D printed polymethylmethacrylate (PMMA) temporary prosthetic crowns, starting from the same digital CAD design. Materials and methods: The study sample included 34 patients presenting 34 premolars in need of prosthetic rehabilitation: a total of 68 temporary crowns were manufactured, 34 of which milled and 34 printed. Immediately after manufacturing, the milled and printed provisionals were scanned with a desktop scanner (E1, 3Shape) to obtain STL files, that were superimposed to the original CAD design in order to identify the occlusal trueness (Analysis A). A second occlusal comparison was performed by scanning both kind of provisional after being placed intraorally with Trios scanner (3 Shape); intraoral scans were obtained in order to compare STL files of provisionals before and after occlusal adjustments (Analysis B). The occlusal trueness was identified at three reference points, P1 (vestibular cusp), P2 (palatal / lingual cusp), P3 (central fossa). The statistical analysis was performed using the R 3.4.3 statistical software (The R Foundation for Statistical Computing), with a significance level of p <0.05. Results: Overall, the printed crowns showed lower occlusal differences than the milled crowns, when compared to the CAD design file, with a statistically significant difference in P1 (difference of 0.025 ± 0.046 mm), P2 (difference of 0.027 ± 0 0.044 mm) and P3 ( difference of 0.018 ± 0.050) for Analysis A (p <0.05). In the Analysis B the direct comparison between the degree of average difference between the pre-adjustment and the post-occlusal adjustment of the milled and printed crowns shows that the printed crowns have lower occlusal mean difference values in all three points compared to the milled ones (difference of 0.146 ± 0.273 mm in P1, 0.285 ± 0.360 mm in P2 and 0.257 ± 0.277 mm in P3). Conclusions: Within the limitation of this study, the data obtained showed a better occlusal surface dimensional accuracy of the 3D printed provisional crowns, when compared to the milled ones. Comparing the results obtained, it is possible to assume that the intraoral scans also had a contribution to occlusion, beside the manufacturing method. 3D printing can be successfully applied for manufacturing temporary PMMA crowns

    Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologies

    Get PDF
    PURPOSE. Digital technology has enabled improvements in the fitting accuracy of denture bases via milling techniques. The aim of this study was to evaluate the trueness and precision of digital and analog techniques for manufacturing complete dentures (CDs). MATERIALS AND METHODS. Sixty identical CDs were manufactured using different production protocols. Digital and analog technologies were compared using the reference geometric approach, and the Delta-error values of eight areas of interest (AOI) were calculated. For each AOI, a precise number of measurement points was selected according to sensitivity analyses to compare the Delta-error of trueness and precision between the original model and manufactured prosthesis. Three types of statistical analysis were performed: to calculate the intergroup cumulative difference among the three protocols, the intergroup among the AOIs, and the intragroup difference among AOIs. RESULTS. There was a statistically significant difference between the dentures made using the oversize process and injection molding process (P < .001), but no significant difference between the other two manufacturing methods (P = .1227). There was also a statistically significant difference between the dentures made using the monolithic process and the other two processes for all AOIs (P = .0061), but there was no significant difference between the other two processes (P = 1). Within each group, significant differences among the AOIs were observed. CONCLUSION. The monolithic process yielded better results, in terms of accuracy (trueness and precision), than the other groups, although all three processes led to dentures with Delta-error values well within the clinical tolerance limit. [J Adv Prosthodont 2023;15:22-32

    Evaluation of trueness and precision of removable partial denture metal frameworks manufactured with digital technology and different materials

    Get PDF
    PURPOSE. The aim of this study is to evaluate the accuracy of removable partial denture (RPD) frameworks produced using different digital protocols. MATERIALS AND METHODS. 80 frameworks for RPDs were produced using CAD-CAM technology and divided into four groups of twenty (n = 20): Group 1, Titanium frameworks manufactured by digital metal laser sintering (DMLS); Group 2, Co-Cr frameworks manufactured by DMLS; Group 3, Polyamide PA12 castable resin manufactured by multi-jet fusion (MJF); and Group 4, Metal (Co-Cr) casting by using lost-wax technique. After the digital acquisition, eight specific areas were selected in order to measure the Δ-error value at the intaglio surface of RPD. The minimum value required for point sampling density (0.4 mm) was derived from the sensitivity analysis. The obtained Δ-error mean value was used for comparisons: 1. between different manufacturing processes; 2. between different manufacturing techniques in the same area of interest (AOI); and 3. between different AOI of the same group. RESULTS. The Δ-error mean value of each group ranged between -0.002 (Ti) and 0.041 (Co-Cr) mm. The Pearson’s Chi-squared test revealed significant differences considering all groups paired two by two, except for group 3 and 4. The multiple comparison test documented a significant difference for each AOI among group 1, 3, and 4. The multiple comparison test showed significant differences among almost all different AOIs of each group. CONCLUSION. All Δ-mean error values of all digital protocols for manufacturing RPD frameworks optimally fit within the clinical tolerance limit of trueness and precision

    Effects of finish line design and fatigue cyclic loading on phase transformation of zirconia dental ceramics: A qualitative micro-raman spectroscopic analysis

    Get PDF
    Objectives: Stresses produced during the fabrication of copings and by chewing activity can induce a tetragonal-to-monoclinic (t-m) transformation of zirconia. As a consequence, in the m-phase, the material is not able to hinder possible cracks by the favorable mechanism known as "transformation toughening". This study aimed at evaluating if different marginal preparations of zirconia copings can cause a premature phase transformation immediately after manufacturing milling and after chewing simulation. Methods: Ninety copings using three commercial zirconia ceramics (Nobel Procera Zirconia, Nobel Biocare Management AG; Lava Classic, 3M ESPE; Lava Plus, 3M ESPE) were prepared with deep-chamfer, slight-chamfer, or feather-edge finish lines (n = 10). Specimens were tested in a chewing simulator (CS-4.4, SD Mechatronik) under cyclic occlusal loads simulating one year of clinical service. Raman spectra were acquired and analyzed for each specimen along the finish lines and at the top of each coping before and after chewing simulation, respectively. Results: Raman analysis did not show any t-m transformation both before and after chewing simulation, as the typical monoclinic bands at 181 cm -1 and 192 cm -1 were not detected in any of the tested specimens. Conclusions: After a one-year simulation of chewing activity, irrespective of preparation geometry, zirconia copings did not show any sign of t-m transformation, either in the load application areas or at the margins. Consequently, manufacturing milling even in thin thickness did not cause any structural modification of zirconia ceramics "as received by manufacturers" both before and after chewing simulation
    • …
    corecore