34 research outputs found

    New optical scheme for a polarimetric-based glucose sensor

    Get PDF
    A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (C) 2004 Society of Photo-Optical Instrumentation Engineers

    Calibration Experiments Conducted for Noninvasive Blood Glucose Sensing Through the Eye

    Get PDF
    There are more than 16 million diabetics in the United States and more than 100 million worldwide. Diabetes can lead to severe complications over time such as blindness, renal and cardiovascular diseases, and peripheral neuropathy in the limbs. Poor blood circulation in diabetics can lead to gangrene and the subsequent amputation of extremities. In addition, this pathology is the fourth leading cause of death in the United States. The most effective way to manage diabetes is frequent blood glucose monitoring performed by the patients themselves. However, because of pain, inconvenience, and the fear of developing infections from finger-prick blood tests or implants, many patients monitor their blood glucose levels less frequently than is recommended by their physicians. Therefore, a noninvasive, painless, and convenient method to monitor blood glucose would greatly benefit diabetics. Likewise, detecting, preventing, and treating the untoward effects of prolonged space travel (e.g., a human mission to Mars) in real-time requires the development of noninvasive diagnostic technologies that are compact and powerful. As a "window to the body," the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and to help develop preventative and therapeutic countermeasures early. The noninvasive feature of these technologies permits frequent repetition of tests, enabling an evaluation of the response to therapy

    The Immune Response to Melanoma Is Limited by Thymic Selection of Self-Antigens

    Get PDF
    The expression of melanoma-associated antigens (MAA) being limited to normal melanocytes and melanomas, MAAs are ideal targets for immunotherapy and melanoma vaccines. As MAAs are derived from self, immune responses to these may be limited by thymic tolerance. The extent to which self-tolerance prevents efficient immune responses to MAAs remains unknown. The autoimmune regulator (AIRE) controls the expression of tissue-specific self-antigens in thymic epithelial cells (TECs). The level of antigens expressed in the TECs determines the fate of auto-reactive thymocytes. Deficiency in AIRE leads in both humans (APECED patients) and mice to enlarged autoreactive immune repertoires. Here we show increased IgG levels to melanoma cells in APECED patients correlating with autoimmune skin features. Similarly, the enlarged T cell repertoire in AIRE−/− mice enables them to mount anti-MAA and anti-melanoma responses as shown by increased anti-melanoma antibodies, and enhanced CD4+ and MAA-specific CD8+ T cell responses after melanoma challenge. We show that thymic expression of gp100 is under the control of AIRE, leading to increased gp100-specific CD8+ T cell frequencies in AIRE−/− mice. TRP-2 (tyrosinase-related protein), on the other hand, is absent from TECs and consequently TRP-2 specific CD8+ T cells were found in both AIRE−/− and AIRE+/+ mice. This study emphasizes the importance of investigating thymic expression of self-antigens prior to their inclusion in vaccination and immunotherapy strategies

    Development of a novel non-invasive sensor for the determination of the blood glucose concentration

    No full text
    Optical methods represent the most promising techniques to perform non-invasive glucose detection. Glucose concentration in the aqueous humor closely mimics glucose levels in the blood and therefore non-invasive optical measurement of glucose can be performed by an optical beam crossing the eye anterior chamber. We propose a polarimetric method that exploits the Brewster-reflection of circularly polarized light on the lens of the eye. After reflection, the resulting linearly polarized light is subject to rotation by the glucose in the aqueous humor and thus carries the concentration information. A preliminary experimental setup, using glucose samples in a beaker, was realized and investigated. \ua9 2001 SPIE \ub7 1605-7422/01/$15.00

    <title>Polarimetric glucose sensing using the Brewster-reflection off the eye lens: theoretical analysis</title>

    No full text
    An important task of in vivo polarimetric glucose sensing is to find an appropriate way to optically access the aqueous humor of the human eye. In this paper two different approaches are analyzed theoretically and applied to the eye model of Le Grand. First approach is the tangential path of Coté et al., and the second is a new scheme of this paper of applying Brewster reflection off the eye lens. © 2002 SPIE · 1605-7422/02/$15.00

    Model-driven web form validation with UML and OCL

    No full text
    Form validation is an integral part of a web application. Web developers must ensure that data input by the user is validated for correctness. Given the importance of form validation it must be considered as part of a model-driven solution to web development. Existing model-driven approaches typically have not addressed form validation as part of the model. In this paper, we present an approach that allows validation constraints to be captured within a model using UML and OCL. Our approach covers three common types of validation: single element, multiple element, and entity association. We provide an example to illustrate an architecture-centric approach
    corecore