1,917,842 research outputs found

    Transmission line for S-band masers

    Get PDF
    Transmission-line is coaxial. Its outer conductor is made of thin-wall stainless-steel tube; inside is plated with 0.0025 mm copper and 0.0003 mm gold. This combination gives little microwave loss and adequate thermal isolation

    Structural matching by discrete relaxation

    Get PDF
    This paper describes a Bayesian framework for performing relational graph matching by discrete relaxation. Our basic aim is to draw on this framework to provide a comparative evaluation of a number of contrasting approaches to relational matching. Broadly speaking there are two main aspects to this study. Firstly we locus on the issue of how relational inexactness may be quantified. We illustrate that several popular relational distance measures can be recovered as specific limiting cases of the Bayesian consistency measure. The second aspect of our comparison concerns the way in which structural inexactness is controlled. We investigate three different realizations ai the matching process which draw on contrasting control models. The main conclusion of our study is that the active process of graph-editing outperforms the alternatives in terms of its ability to effectively control a large population of contaminating clutter

    Measurements of induced radioactivity in some LDEF samples

    Get PDF
    Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 percent at 1332 keV. Detector efficiencies as a function of energy and corrections for self-absorption in the samples were determined with calibrated sources and unactivated control samples. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum and titanium samples, Na-22 was detected. Other results are presented

    Is SGR 1900+14 a Magnetar?

    Get PDF
    We present RXTE observations of the soft gamma--ray repeater SGR 1900+14 taken September 4-18, 1996, nearly 2 years before the 1998 active period of the source. The pulsar period (P) of 5.1558199 +/- 0.0000029 s and period derivative (Pdot) of (6.0 +/- 1.0) X 10^-11 s/s measured during the 2-week observation are consistent with the mean Pdot of (6.126 +/- 0.006) X 10^-11 s/s over the time up to the commencement of the active period. This Pdot is less than half that of (12.77 +/- 0.01) X 10^-11 s/s observed during and after the active period. If magnetic dipole radiation were the primary cause of the pulsar spindown, the implied pulsar magnetic field would exceed the critical field of 4.4 X 10^13 G by more than an order of magnitude, and such field estimates for this and other SGRs have been offered as evidence that the SGRs are magnetars, in which the neutron star magnetic energy exceeds the rotational energy. The observed doubling of Pdot, however, would suggest that the pulsar magnetic field energy increased by more than 100% as the source entered an active phase, which seems very hard to reconcile with models in which the SGR bursts are powered by the release of magnetic energy. Because of this, we suggest that the spindown of SGR pulsars is not driven by magnetic dipole radiation, but by some other process, most likely a relativistic wind. The Pdot, therefore, does not provide a measure of the pulsar magnetic field strength, nor evidence for a magnetar.Comment: 14 pages, aasms4 latex, figures 1 & 2 changed, accepted by ApJ letter

    Position location and data collection system and method Patent

    Get PDF
    Development of telemetry system for position location and data acquisitio
    corecore