5 research outputs found

    INDUÇÃO DA PRODUÇÃO DE ÓXIDO NÍTRICO EM CULTURA DE MACRÓFAGOS PERITONEAIS DE CAMUNDONGOS PELOS CIMENTOS ENDODÔNTICOS SEALAPEX E TOPSEAL

    Get PDF
    Avaliou-se em cultura de macrófagos peritoneais de camundongosa citotoxicidade dos cimentos endodônticos, Topseal e Sealapex, quantoà indução da produção de óxido nítrico (NO). Após a pulverização,100ml da suspensão, contendo 18mg/ml dos respectivos cimentos, foramadicionados em placa de cultura de tecido, contendo macrófagos naconcentração de 5,0X106 células/ml. Após incubação, a 37ºC, em 5% deCO2, verificou-se pelo leitor ELISA automático que a produção de NOpelo Topseal variou de 191,7 a 321,5 mmols, enquanto para o Sealapexesses valores foram significativamente menores, da ordem de 38,6 a 106,7mmols.Possivelmente, a maior citotoxicidade do Topseal deve-se à presença daresina epóxica e à liberação de formaldeído

    Avaliação da citotoxicidade de dois cimentos endodônticos em cultura de macrófagos

    Get PDF
    Compared to gutta-percha, the endodontic cements are used in small quantity to seal root canals, but are indispensable to achieve hermetically sealed margins, where its biocompatibility depends on the sum of responses of each cell present in the periapical region. The object of this study was to evaluate the cytotoxicity of two endodontic cements, one based on epoxy resin (Sealer 26) and the other containing zinc oxide eugenol (Endofill) by using cultured peritoneal macrophages from Swiss mice to measure the induced production of nitric oxide. After solidification and pulverization, aliquots of 100mul of suspension containing 18mg/mL of the respective cements were added to 96-well tissue culture plates containing the tissue culture of macrophages at a concentration of 5.0X10(6) cells/ml. In the positive control group the cell culture was treated with 10mg/mL of lipopolyssaccharide from Escherichia coli 026:B6 and the cell culture alone represented the negative control. After 48 hours of incubation, at 37ºC, in 5% CO2, the cultures were placed in an ELISA automatic reader to evaluate the release of nitric oxide. The production of nitric oxide for cement Sealer 26 was between 36.1 and 313.0 mumols, with a mean of 143.82±111.03mumols, while for the Endofill these values were significantly less (p=0.01), varying from 50.8 to 125.7mumols, with a mean of 80.33±28.42 mumols. In the positive and negative control groups the mean release of nitric oxide was of 162.75mumols and 4.42mumols, respectively. There was no significant difference between the positive control group and cement Sealer 26 (p>;0.05). Therefore, the cement Sealer 26 caused significantly greater toxicity to the macrophages, possibly due to the components from the epoxy resin and formaldehyde release during polymerization.Comparativamente à guta-percha, os cimentos endodônticos são utilizados em pequena quantidade nas obturações dos canais radiculares, mas são imprescindíveis para obtenção do hermético selamento marginal, sendo sua biocompatibilidade dependente do somatório das respostas de cada célula presente na região periapical. Por conseguinte, o objetivo deste estudo foi avaliar em cultura de macrófagos peritoneais de seis camundongos Swiss, a citotoxicidade de dois cimentos endodônticos, um à base de resina epóxica (Sealer 26) e outro contendo óxido de zinco e eugenol (Endofill), quanto a indução da produção de óxido nítrico. Após a presa e pulverização, alíquotas de 100ml da suspensão contendo 18mg/mL dos respectivos cimentos foram adicionados em placa de cultura de tecido de 96 poços, contendo a cultura de macrófagos na concentração de 5,0X10(6) células/ml. Após 48 horas de incubação, a 37ºC, em 5% de CO2, foi feita a leitura em um leitor ELISA automático para se averiguar a liberação de óxido nítrico. Verificou-se, para o cimento Sealer 26, que a produção de óxido nítrico oscilou de 36,1 a 313,0 mimols, com média de 143,82±111,03, enquanto para o Endofill estes valores foram significativamente menores (p=0.01), variando de 50,8 a 125,7, com média de 80.33±28,42 mols. Nos grupos controles positivo e negativo a média de liberação de óxido nítrico foi de 162,75mimols e 4,42mimols, respectivamente. Não houve diferença significativa entre o grupo controle positivo e o cimento Sealer 26 (p>;0.05). Portanto, o cimento Sealer 26 causou, significativamente, maior toxicidade aos macrófagos, possivelmente devido aos seus componentes, a exemplo da resina epóxica e ao formaldeído, liberados durante a sua reação de polimerização

    Evaluation of cytotoxicity of two endodontic cements in a macrophage culture

    No full text
    Compared to gutta-percha, the endodontic cements are used in small quantity to seal root canals, but are indispensable to achieve hermetically sealed margins, where its biocompatibility depends on the sum of responses of each cell present in the periapical region. The object of this study was to evaluate the cytotoxicity of two endodontic cements, one based on epoxy resin (Sealer 26) and the other containing zinc oxide eugenol (Endofill) by using cultured peritoneal macrophages from Swiss mice to measure the induced production of nitric oxide. After solidification and pulverization, aliquots of 100mul of suspension containing 18mg/mL of the respective cements were added to 96-well tissue culture plates containing the tissue culture of macrophages at a concentration of 5.0X10(6) cells/ml. In the positive control group the cell culture was treated with 10mg/mL of lipopolyssaccharide from Escherichia coli 026:B6 and the cell culture alone represented the negative control. After 48 hours of incubation, at 37ºC, in 5% CO2, the cultures were placed in an ELISA automatic reader to evaluate the release of nitric oxide. The production of nitric oxide for cement Sealer 26 was between 36.1 and 313.0 mumols, with a mean of 143.82±111.03mumols, while for the Endofill these values were significantly less (p=0.01), varying from 50.8 to 125.7mumols, with a mean of 80.33±28.42 mumols. In the positive and negative control groups the mean release of nitric oxide was of 162.75mumols and 4.42mumols, respectively. There was no significant difference between the positive control group and cement Sealer 26 (p>0.05). Therefore, the cement Sealer 26 caused significantly greater toxicity to the macrophages, possibly due to the components from the epoxy resin and formaldehyde release during polymerization

    Análise morfológica sequencial da resposta tissular ao implante de dois diferentes materiais retrobturadores no tecido subcutâneo de ratos wistar

    No full text
    Submitted by Ana Maria Fiscina Sampaio ([email protected]) on 2015-06-16T16:37:11Z No. of bitstreams: 1 Vita WS Análise morfológica sequencial....pdf: 1847355 bytes, checksum: 800656efe97a2cb3c86d8c612c620c70 (MD5)Approved for entry into archive by Ana Maria Fiscina Sampaio ([email protected]) on 2015-06-16T16:52:58Z (GMT) No. of bitstreams: 1 Vita WS Análise morfológica sequencial....pdf: 1847355 bytes, checksum: 800656efe97a2cb3c86d8c612c620c70 (MD5)Made available in DSpace on 2015-06-16T16:52:58Z (GMT). No. of bitstreams: 1 Vita WS Análise morfológica sequencial....pdf: 1847355 bytes, checksum: 800656efe97a2cb3c86d8c612c620c70 (MD5) Previous issue date: 2008Universidade Estadual de Feira de Santana. (UEFS). Feira de Santana, BA, Brasil / Fundação Oswaldo Cruz. Centro de Pesquisas Gonçalo Moniz. Salvador, BA, BrasilUniversidade Federal da Bahia. Faculdade de Medicina. Salvador, BA, Brasil / Fundação Oswaldo Cruz. Centro de Pesquisas Gonçalo Moniz. Salvador, BA, BrasilUniversidade Federal de São Paulo (UNESP). Araraquara, SP, Brasil / Universidade Estadual de Feira de Santana. (UEFS). Feira de Santana, BA, BrasilUniversidade Federal da Bahia. Salvador, BA, Brasil / Fundação Oswaldo Cruz. Centro de Pesquisas Gonçalo Moniz. Salvador, BA, BrasilUniversidade Federal da Bahia. Salvador, BA, BrasilO objetivo do presente estudo foi analisar a resposta histomorfológica do tecido subcutâneo de ratos ao implante do Agregado Trióxido Mineral (MTA MTA) e Sealapex acrescido de óxido de zinco (Sealapex consistente), indicados como materiais retrobturadores. Foram utilizados 40 ratos distribuídos em grupos de dois animais para cada período experimental: 2, 7, 30 e 60 dias. Cada animal recebeu três implantes com o mesmo material, cada um considerado uma amostra de estudo, num total de até seis amostras por grupo. As respostas do tecido conjuntivo em contato com os materiais retrobturadores foram avaliadas de forma descritiva e semiquantitativa através de escores (0 = ausente; 1 = discreto; 2 = moderado; 3 = intenso), analisando-se a inflamação, presença de necrose, edema, tecido de granulação, fibrose e calcificações. Para comparação entre os grupos, os dados foram submetidos à análise de variância, teste de Kruskal-Wallis e o pós-teste de Student-Newman-Keuls com nível de significância α = 0,05. No período de 60 dias, para os parâmetros histomorfológicos analisados, não foi possível identificar associação estatística. Os resultados demonstraram que, com o passar do tempo, ambos os materiais despertaram reação tecidual semelhante, representada por redução da resposta inflamatória, discreta fibrose e presença de áreas basófilas calcificadas, corroborando à sua biocompatibilidaderatsThe aim of this study was to analyze the histomorphological response of the subcutaneous tissue of rats to the implant of mineral trioxide aggregate (MTA) and Sealapex added to oxide of zinc (Consistent Sealapex) used as retrograde filling materials. Forty rats were divided into groups of two animals for each experimental period: 2, 7, 30 and 60 days. Each animal received three implants and each one of them was considered a sample. Overall, there were six samples/animal. It was performed a descriptive and semi-quantitative histopathological analysis using the scores (0 = none; 1 = mild; 2 = moderate; 3 = severe) for the following parameters: inflammation, necrosis, edema, granulation tissue, fibrosis and calcification. For statistical analysis, it was used Kruskal-wallis and Post-test of Student-Neuman-Keuls (α = 0,05). The comparation between MTA and Consistent Sealapex showed smaller edema (p < 0,005) for the group of MTA in a period of seven days. In a period of 30 days, there was larger calcification (p < 0,005). In the period of 60 days, it was not possible to identify statistical association. The results showed that, in the assessed periods of times, both materials exhibited similar tissue response. This finding was observed by the reduction of inflammatory response, discreet fibrosis and calcifications favoring their biocompatibility
    corecore