10 research outputs found

    Semiautomatic Assessment of the Terminal Ileum and Colon in Patients with Crohn Disease Using MRI (the VIGOR++ Project)

    Get PDF
    Rationale and Objectives: The objective of this study was to develop and validate a predictive magnetic resonance imaging (MRI) activity score for ileocolonic Crohn disease activity based on both subjective and semiautomatic MRI features. Materials and Methods: An MRI activity score (the “virtual gastrointestinal tract [VIGOR]” score) was developed from 27 validated magnetic resonance enterography datasets, including subjective radiologist observation of mural T2 signal and semiautomatic measurements of bowel wall thickness, excess volume, and dynamic contrast enhancement (initial slope of increase). A second subjective score was developed based on only radiologist observations. For validation, two observers applied both scores and three existing scores to a prospective dataset of 106 patients (59 women, median age 33) with known Crohn disease, using the endoscopic Crohn's Disease Endoscopic Index of Severity (CDEIS) as a reference standard. Results: The VIGOR score (17.1 × initial slope of increase + 0.2 × excess volume + 2.3 × mural T2) and other activity scores all had comparable correlation to the CDEIS scores (observer 1: r = 0.58 and 0.59, and observer 2: r = 0.34–0.40 and 0.43–0.51, respectively). The VIGOR score, however, improved interobserver agreement compared to the other activity scores (intraclass correlation coefficient = 0.81 vs 0.44–0.59). A diagnostic accuracy of 80%–81% was seen for the VIGOR score, similar to the other scores. Conclusions: The VIGOR score achieves comparable accuracy to conventional MRI activity scores, but with significantly improved reproducibility, favoring its use for disease monitoring and therapy evaluation

    Katayama Fever

    No full text
    During an elective in Uganda, a 24-year-old Dutch medical student swam in the Nile River. Two months after his return, he presented with a nonproductive cough and malaise, as well as diarrhea and nonpruritic rash. Examination revealed multiple small papules on the trun

    Long-Term Performance of Readers Trained in Grading Crohn Disease Activity Using MRI

    No full text
    We aim to evaluate the long-term performance of readers who had participated in previous magnetic resonance imaging (MRI) reader training in grading Crohn disease activity. Fourteen readers (8 women; 12 radiologists, 2 residents; mean age 40; range 31-59), who had participated in a previous MRI reader training, participated in a follow-up evaluation after a mean interval of 29 months (range 25-34 months). Follow-up evaluation comprised 25 MRI cases of suspected or known Crohn disease patients with direct feedback; cases were identical to the evaluation set used in the initial reader training (of which readers were unaware). Grading accuracy, overstaging, and understaging were compared between training and follow-up using a consensus score by two experienced abdominal radiologists as the reference standard. In the follow-up evaluation, overall grading accuracy was 73% (95% confidence interval [CI]: 62%-81%), which was comparable to reader training grading accuracy (72%, 95% CI: 61%-80%) (P = .66). Overstaging decreased significantly from 19% (95% CI: 12%-27%) to 13% (95% CI: 8%-21%) between training and follow-up (P = .03), whereas understaging increased significantly from 9% (95% CI: 4%-21%) to 14% (95% CI: 7%-26%) (P  < .01). Readers have consistent long-term accuracy for grading Crohn disease activity after case-based reader training with direct feedbac

    Expiration-phase template-based motion correction of free-breathing abdominal dynamic contrast enhanced MRI

    No full text
    This paper studies a novel method to compensate for respiratory and peristaltic motions in abdominal dynamic contrast enhanced magnetic resonance imaging. The method consists of two steps: 1) expiration-phase "template" construction and retrospective gating of the data to the template; and 2) nonrigid registration of the gated volumes. Landmarks annotated by three experts were used to directly assess the registration performance. A tri-exponential function fit to time intensity curves from regions of interest was used to indirectly assess the performance. One of the parameters of the tri-exponential fit was used to quantify the contrast enhancement. Our method achieved a mean target registration error (MTRE) of 2.12, 2.27, and 2.33 mm with respect to annotations by expert, which was close to the average interobserver variability (2.07 mm). A state-of-the-art registration method achieved an MTRE of 2.83-3.10 mm. The correlation coefficient of the contrast enhancement parameter to the Crohn's disease endoscopic index of Severity (r = 0.60, p = 0.004) was higher than the correlation coefficient for the relative contrast enhancement measurements values of two observers ( r(Observer 1) = 0.29, p = 0.2; r(Observer 2) = 0.45, p = 0.04). Direct and indirect assessments show that the expiration-based gating and a nonrigid registration approach effectively corrects for respiratory motion and peristalsis. The method facilitates improved enhancement measurement in the bowel wall in patients with Crohn's diseas

    Semi-automatic bowel wall thickness measurements on MR enterography in patients with Crohn's disease

    Get PDF
    To evaluate a semi-automatic method for delineation of the bowel wall and measurement of the wall thickness in patients with Crohn's disease. 53 patients with suspected or proven Crohn's disease were selected. Two radiologists independently supervised the delineation of regions with active Crohn's disease on MRI, yielding manual annotations (Ano1, Ano2). Three observers manually measured the maximal bowel wall thickness of each annotated segment. An active contour segmentation approach semi-automatically delineated the bowel wall. For each active region, two segmentations (Seg1, Seg2) were obtained by independent observers, in which the maximum wall thickness was automatically determined. The overlap between (Seg1, Seg2) was compared with the overlap of (Ano1, Ano2) using Wilcoxon's signed rank test. The corresponding variances were compared using the Brown-Forsythe test. The variance of the semi-automatic thickness measurements was compared with the overall variance of manual measurements through an F-test. Furthermore, the intraclass correlation coefficient (ICC) of semi-automatic thickness measurements was compared with the ICC of manual measurements through a likelihood-ratio test. Patient demographics: median age, 30 years; interquartile range, 25-38 years; 33 females. The median overlap of the semi-automatic segmentations (Seg1 vs Seg2: 0.89) was significantly larger than the median overlap of the manual annotations (Ano1 vs Ano2: 0.72); p = 1.4 × 10(-5). The variance in overlap of the semi-automatic segmentations was significantly smaller than the variance in overlap of the manual annotations (p = 1.1 × 10(-9)). The variance of the semi-automated measurements (0.46 mm(2)) was significantly smaller than the variance of the manual measurements (2.90 mm(2), p = 1.1 × 10(-7)). The ICC of semi-automatic measurement (0.88) was significantly higher than the ICC of manual measurement (0.45); p = 0.005. The semi-automatic technique facilitates reproducible delineation of regions with active Crohn's disease. The semi-automatic thickness measurement sustains significantly improved interobserver agreement. Advances in knowledge: Automation of bowel wall thickness measurements strongly increases reproducibility of these measurements, which are commonly used in MRI scoring systems of Crohn's disease activit

    Relationship between MRI quantified small bowel motility and abdominal symptoms in Crohn's disease patients-a validation study

    Get PDF
    Objective: Previous single-centre MRI data suggests an inverse correlation between normal small bowel motility variance and abdominal symptoms in Crohn's disease (CD) patients. The current work prospectively assesses this observation in a larger, two-centre study. Methods: MR enterography datasets were analysed from 82 patients (38 male, aged 16-68), who completed a contemporaneous Harvey-Bradshaw index (HBI) questionnaire. Dynamic "cine motility" breath-hold balanced steady-state free precession sequences were acquired through the whole small bowel (SB) volume. Regions of interest (ROIs) were manually applied to encompass all morphologically normal SB (i.e. excluding Crohn's affected bowel) and a validated registration technique used to produce motility maps. Mean variance motility metrics were correlated with HBI and symptom components (well-being, pain and diarrhoea) using Spearman's correlation statistics. Results: Overall, motility variance was non-significantly negatively correlated with the total HBI score, (r = -0.17, p = 0.12), but for subjects with a HBI score over 10, the negative correlation was significant (r = -0.633, p = 0.027). Motility variance was negatively correlated with diarrhoea (r = -0.29, p &lt; 0.01). No significant correlation was found between mean motility and HBI (r = -0.02, p = 0.84). Conclusion: An inverse association between morphologically normal small bowel motility variance and patient symptoms has been prospectively confirmed in patients with HBI scores above 10. This association is particularly apparent for the symptom of diarrhoea. Advances in knowledge: This study builds on preliminary work by confirming in a large, well-controlled prospective multicentre study a relationship between normal bowel motility variance and patient reported symptoms which may have implications for drug development and clinical management. Relationship between MRI quantified small bowel motility and abdominal symptoms in Crohn’s disease patients—a validation study | Request PDF. Available from: https://www.researchgate.net/publication/325706806_Relationship_between_MRI_quantified_small_bowel_motility_and_abdominal_symptoms_in_Crohn%27s_disease_patients-a_validation_study [accessed Oct 09 2018].ImPhys/Quantitative Imagin

    Il popolamento animale e vegetale dell'Appennino centrale

    No full text
    OBJECTIVE: The purpose of this study was to evaluate four previously validated MRI activity scoring systems for diagnosis and grading of Crohn disease (CD) in the terminal ileum against an endoscopic and histopathologic reference standard. SUBJECTS AND METHODS: Ethics approval and written informed consent were obtained. Subjects with known or suspected CD were prospectively recruited between December 2011 and August 2014. Each patient underwent MRI and ileocolonoscopy with terminal ileum biopsies. Four MRI scoring systems (Magnetic Resonance Index of Activity [MaRIA], Clermont score, London score, and Crohn disease MRI Index) and component features were applied by two observers and correlated to the Crohn disease endoscopic index of severity (CDEIS, 0-44) and histopathologic endoscopic acute inflammation score (0-6). Interobserver agreement (weighted kappa and intraclass correlation coefficient [ICC]) and diagnostic accuracy for active and ulcerating endoscopic or histopathologic disease were evaluated. RESULTS: Ninety-eight patients (median age, 32 years old; 55 women, 43 men) were included. All four scoring systems showed good interobserver agreement (ICC = 0.70-0.78), moderate-to-strong correlation to CDEIS (r = 0.57-0.67) and weak-to-moderate correlation to endoscopic acute inflammation score (r = 0.38-0.49). Scoring systems' diagnostic accuracy for active and ulcerating endoscopic disease ranged from 73% to 78% and 71% to 76%, respectively, whereas for active histopathologic disease accuracy ranged from 65% to 72%. Between the scoring systems, no significant differences were found for both observers regarding interobserver agreement, correlation coefficients, and diagnostic accuracy. CONCLUSION: All scoring systems were comparable in terms of interobserver agreement, correlation to the endoscopic and histopathologic reference standard, and diagnostic accuracy. The London score, MaRIA, and Clermont score have the additional benefit of having validated cutoff values for both active and ulcerating endoscopic disease

    Yield of Screening for COVID-19 in Asymptomatic Patients Before Elective or Emergency Surgery Using Chest CT and RT-PCR (SCOUT): Multicenter Study

    No full text
    OBJECTIVE: To determine the yield of preoperative screening for COVID-19 with chest CT and RT-PCR in patients without COVID-19 symptoms. SUMMARY OF BACKGROUND DATA: Many centers are currently screening surgical patients for COVID-19 using either chest CT, RT-PCR or both, due to the risk for worsened surgical outcomes and nosocomial spread. The optimal design and yield of such a strategy are currently unknown. METHODS: This multicenter study included consecutive adult patients without COVID-19 symptoms who underwent preoperative screening using chest CT and RT-PCR before elective or emergency surgery under general anesthesia. RESULTS: A total of 2093 patients without COVID-19 symptoms were included in 14 participating centers; 1224 were screened by CT and RT-PCR and 869 by chest CT only. The positive yield of screening using a combination of chest CT and RT-PCR was 1.5% [95% confidence interval (CI): 0.8-2.1]. Individual yields were 0.7% (95% CI: 0.2-1.1) for chest CT and 1.1% (95% CI: 0.6-1.7) for RT-PCR; the incremental yield of chest CT was 0.4%. In relation to COVID-19 community prevalence, up to ∼6% positive RT-PCR was found for a daily hospital admission rate >1.5 per 100,000 inhabitants, and around 1.0% for lower prevalence. CONCLUSIONS: One in every 100 patients without COVID-19 symptoms tested positive for SARS-CoV-2 with RT-PCR; this yield increased in conjunction with community prevalence. The added value of chest CT was limited. Preoperative screening allowed us to take adequate precautions for SARS-CoV-2 positive patients in a surgical population, whereas negative patients needed only routine procedures

    Yield of Screening for COVID-19 in Asymptomatic Patients Before Elective or Emergency Surgery Using Chest CT and RT-PCR (SCOUT): Multicenter Study

    Get PDF
    OBJECTIVE: To determine the yield of preoperative screening for COVID-19 with chest CT and RT-PCR in patients without COVID-19 symptoms. SUMMARY OF BACKGROUND DATA: Many centers are currently screening surgical patients for COVID-19 using either chest CT, RT-PCR or both, due to the risk for worsened surgical outcomes and nosocomial spread. The optimal design and yield of such a strategy are currently unknown. METHODS: This multicenter study included consecutive adult patients without COVID-19 symptoms who underwent preoperative screening using chest CT and RT-PCR before elective or emergency surgery under general anesthesia. RESULTS: A total of 2093 patients without COVID-19 symptoms were included in 14 participating centers; 1224 were screened by CT and RT-PCR and 869 by chest CT only. The positive yield of screening using a combination of chest CT and RT-PCR was 1.5% [95% confidence interval (CI): 0.8-2.1]. Individual yields were 0.7% (95% CI: 0.2-1.1) for chest CT and 1.1% (95% CI: 0.6-1.7) for RT-PCR; the incremental yield of chest CT was 0.4%. In relation to COVID-19 community prevalence, up to ∼6% positive RT-PCR was found for a daily hospital admission rate >1.5 per 100,000 inhabitants, and around 1.0% for lower prevalence. CONCLUSIONS: One in every 100 patients without COVID-19 symptoms tested positive for SARS-CoV-2 with RT-PCR; this yield increased in conjunction with community prevalence. The added value of chest CT was limited. Preoperative screening allowed us to take adequate precautions for SARS-CoV-2 positive patients in a surgical population, whereas negative patients needed only routine procedures
    corecore