10 research outputs found

    MOSCAB (Materia OSCura A Bolle)

    Get PDF
    This kind of detector (Geyser) has never been realized for the Elementary Particle Physics (it was constructed once in BERN A in 1964 by Hahn and Reist to detect transuranic nuclei. The Geyser is substantially a Vessel consisting of a "FLASK" containing a superheated liquid (f.i. some kind of freon) and a "NECK" (containing partially a separation liquid and partially the freon vapor). The Geyser was realized in Milano by setting the two different parts of the detector (flask and neck, filled in our case by freon C3 F8 , at different temperatures. The part of the overheated liquid was kept at higher temperature (f.i. 25 degree) and the gaseous part was kept at lower temperature (f.i. 18 degrees)

    Energy Resolution Performance of the CMS Electromagnetic Calorimeter

    Get PDF
    The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals

    Improving Upper Extremity Bradykinesia in Parkinson’s Disease: A Randomized Clinical Trial on the Use of Gravity-Supporting Exoskeletons

    No full text
    Hand movements are particularly impaired in patients with Parkinson’s Disease (PD), contributing to functional disability and difficulties in activities of daily living. Growing evidence has shown that robot-assisted therapy may be considered an effective and reliable method for the delivery of the highly repetitive training that is needed to trigger neuroplasticity, as intensive, repetitive and task-oriented training could be an ideal strategy to facilitate the relearning of motor function and to minimize motor deficit. The purpose of this study is to evaluate the improvement of hand function with semi-autonomous exercises using an upper extremity exoskeleton in patients with PD. A multicenter, parallel-group, randomized clinical trial was then carried out at the IRCCS Centro Neurolesi Bonino-Pulejo (Messina, Italy). Thirty subjects with a diagnosis of PD and a Hoehn–Yahr score between 2 and 3 were enrolled in the study. Patients were 1:1 randomized into either the experimental group (ERT), receiving 45 min training daily, 6 days weekly, for 8 weeks with Armeo®Spring (Volketswil, Switzerland) (a gravity-supporting device), or the control group (CPT), which was subjected to the same amount of conventional physical therapy. Motor abilities were assessed before and after the end of the training. The main outcomes measures were the Nine-hole peg test and the motor section of the UPDRS. All patients belonging to ERT and 9 out of 15 patients belonging to the CPT completed the trial. ERT showed a greater improvement in the primary outcome measure (nine-hole peg test) than CPT. Moreover, a statistically significant improvement was found in ERT concerning upper limb mobility, and disease burden as compared to CPT. Using an upper extremity exoskeleton (i.e., the Armeo®Spring) for semi-autonomous training in an inpatient setting is a new perspective to train patients with PD to improve their dexterity, executive function and, potentially, quality of life

    Inter-calibration of the CMS electromagnetic calorimeter with cosmic rays before installation

    No full text
    The possibility of using cosmic rays to pre-calibrate the ECAL barrel electromagnetic calorimeter of the CMS experiment was investigated using real data collected with a cosmic telescope and simulated data based on the GEANT4 toolkit. The data collected are well described by simulation and confirm that an inter-calibration of the calorimeter channels after assembly in super-modules can be performed with sufficiently good precision even without an external tracking device, following a schedule compatible with the CMS construction plans. A possible selective trigger setup based on scintillator planes is also proposed

    Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter

    Get PDF
    The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by summing the energy measured in arrays of 3x3 or 5x5 channels. There was no significant amount of correlated noise observed within these arrays. For electrons incident at the centre of the studied 3x3 arrays of crystals, the mean stochastic term was measured to be 2.8% and the mean constant term to be 0.3%. The amount of the incident electron's energy which is contained within the array depends on its position of incidence. The variation of the containment with position is corrected for using the distribution of the measured energy within the array. For uniform illumination of a crystal with 120 GeV electrons a resolution of 0.5% was achieved. The energy resolution meets the design goal for the detector

    Results of the first performance tests of the CMS electromagnetic calorimeter

    No full text
    CMS ECALPerformance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to validate prototypes of the new Very Front End electronics. The final versions of the monitoring and cooling systems, and of the high and low voltage regulation were used in these tests. The results are consistent with the performance targets including those for noise and overall energy resolution, required to fulfil the physics programme of CMS at the LHC

    The CMS Barrel Calorimeter Response to Particle Beams from 2 to 350 GeV/c

    No full text
    The response of the CMS barrel calorimeter (electromagnetic plus hadronic) to hadrons, electrons and muons over a wide momentum range from 2 to 350 GeV/c has been measured. To our knowledge, this is the widest range of momenta in which any calorimeter system has been studied. These tests, carried out at the H2 beam-line at CERN, provide a wealth of information, especially at low energies. The analysis of the differences in calorimeter response to charged pions, kaons, protons and antiprotons and a detailed discussion of the underlying phenomena are presented. We also show techniques that apply corrections to the signals from the considerably different electromagnetic (EB) and hadronic (HB) barrel calorimeters in reconstructing the energies of hadrons. Above 5 GeV/c, these corrections improve the energy resolution of the combined system where the stochastic term equals 84.7±\pm1.6%\% and the constant term is 7.4±\pm0.8%\%. The corrected mean response remains constant within 1.3%\% rms

    Transverse momentum and pseudorapidity distributions of charged hadrons in pp collisions at (s)\sqrt(s) = 0.9 and 2.36 TeV

    Get PDF
    Measurements of inclusive charged-hadron transverse-momentum and pseudorapidity distributions are presented for proton-proton collisions at sqrt(s) = 0.9 and 2.36 TeV. The data were collected with the CMS detector during the LHC commissioning in December 2009. For non-single-diffractive interactions, the average charged-hadron transverse momentum is measured to be 0.46 +/- 0.01 (stat.) +/- 0.01 (syst.) GeV/c at 0.9 TeV and 0.50 +/- 0.01 (stat.) +/- 0.01 (syst.) GeV/c at 2.36 TeV, for pseudorapidities between -2.4 and +2.4. At these energies, the measured pseudorapidity densities in the central region, dN(charged)/d(eta) for |eta| < 0.5, are 3.48 +/- 0.02 (stat.) +/- 0.13 (syst.) and 4.47 +/- 0.04 (stat.) +/- 0.16 (syst.), respectively. The results at 0.9 TeV are in agreement with previous measurements and confirm the expectation of near equal hadron production in p-pbar and pp collisions. The results at 2.36 TeV represent the highest-energy measurements at a particle collider to date
    corecore