7 research outputs found

    Validation of a Device for the Ambulatory Monitoring of Sleep Patterns: A Pilot Study on Parkinson's Disease

    Get PDF
    The development of wearable devices has increase interest in the use of ambulatory methods to detect sleep disorders more objectively than those permitted by subjective scales evaluating sleep quality, while subjects maintain their usual lifestyle. This study aims to validate an ambulatory circadian monitoring (ACM) device for the detection of sleep and wake states and apply it to the evaluation of sleep quality in patients with Parkinson disease (PD). A polysomnographic validation study was conducted on a group of patients with different sleep disorders in a preliminary phase, followed by a pilot study to apply this methodology to PD patients. The ACM device makes it possible to estimate the main sleep parameters very accurately, as demonstrated by: (a) the lack of significant differences between the mean values detected by PSG and ACM in time in bed (TIB), total sleep time (TST), sleep efficiency (SE), and time awake after sleep onset (WASO); (b) the slope of the correlation lines between the parameters estimated by the two procedures, very close to 1, which demonstrates the linearity of the predictions; (c) the low bias value in the estimates obtained through ACM. Sleep in PD is associated with lower distal skin temperature, efficiency and overall sleep time; greater WASO, activity during sleep and duration of naps and a worse circadian function index. In summary, the ACM device has proven to be clinically useful to evaluate sleep in an objective manner, thanks to the integrated management of different complementary variables, having advantages over conventional actigraphy

    International Consensus Document on Obstructive Sleep Apnea

    Get PDF
    El objetivo principal de este documento internacional de consenso sobre apnea obstructiva del sueno es proporcionar unas directrices que permitan a los profesionales sanitarios tomar las mejores decisiones en la asistencia de los pacientes adultos con esta enfermedad según un resumen crítico de la literatura más actualizada. El grupo de trabajo de expertos se ha constituido principalmente por 17 sociedades científicas y 56 especialistas con amplia representación geográfica (con la participación de 4 sociedades internacionales), además de un metodólogo experto y un documentalista del Centro Cochrane Iberoamer icano. El documento consta de un manuscrito principal, con las novedades más relevantes del DIC, y una serie de manuscritos online que recogen las búsquedas bibliográficas sistemáticas de cada uno de los apartados del DIC. Este documento no cubre la edad pediátrica ni el manejo del paciente en ventilación mecánica crónica no invasiva (que se publicarán en sendos documentos de consenso aparte)

    CIBERER : Spanish national network for research on rare diseases: A highly productive collaborative initiative

    Get PDF
    Altres ajuts: Instituto de Salud Carlos III (ISCIII); Ministerio de Ciencia e Innovación.CIBER (Center for Biomedical Network Research; Centro de Investigación Biomédica En Red) is a public national consortium created in 2006 under the umbrella of the Spanish National Institute of Health Carlos III (ISCIII). This innovative research structure comprises 11 different specific areas dedicated to the main public health priorities in the National Health System. CIBERER, the thematic area of CIBER focused on rare diseases (RDs) currently consists of 75 research groups belonging to universities, research centers, and hospitals of the entire country. CIBERER's mission is to be a center prioritizing and favoring collaboration and cooperation between biomedical and clinical research groups, with special emphasis on the aspects of genetic, molecular, biochemical, and cellular research of RDs. This research is the basis for providing new tools for the diagnosis and therapy of low-prevalence diseases, in line with the International Rare Diseases Research Consortium (IRDiRC) objectives, thus favoring translational research between the scientific environment of the laboratory and the clinical setting of health centers. In this article, we intend to review CIBERER's 15-year journey and summarize the main results obtained in terms of internationalization, scientific production, contributions toward the discovery of new therapies and novel genes associated to diseases, cooperation with patients' associations and many other topics related to RD research

    Validation of a Device for the Ambulatory Monitoring of Sleep Patterns: A Pilot Study on Parkinson's Disease.

    No full text
    The development of wearable devices has increase interest in the use of ambulatory methods to detect sleep disorders more objectively than those permitted by subjective scales evaluating sleep quality, while subjects maintain their usual lifestyle. This study aims to validate an ambulatory circadian monitoring (ACM) device for the detection of sleep and wake states and apply it to the evaluation of sleep quality in patients with Parkinson disease (PD). A polysomnographic validation study was conducted on a group of patients with different sleep disorders in a preliminary phase, followed by a pilot study to apply this methodology to PD patients. The ACM device makes it possible to estimate the main sleep parameters very accurately, as demonstrated by: (a) the lack of significant differences between the mean values detected by PSG and ACM in time in bed (TIB), total sleep time (TST), sleep efficiency (SE), and time awake after sleep onset (WASO); (b) the slope of the correlation lines between the parameters estimated by the two procedures, very close to 1, which demonstrates the linearity of the predictions; (c) the low bias value in the estimates obtained through ACM. Sleep in PD is associated with lower distal skin temperature, efficiency and overall sleep time; greater WASO, activity during sleep and duration of naps and a worse circadian function index. In summary, the ACM device has proven to be clinically useful to evaluate sleep in an objective manner, thanks to the integrated management of different complementary variables, having advantages over conventional actigraphy

    Pitolisant for Residual Excessive Daytime Sleepiness in OSA Patients Adhering to CPAP

    No full text
    International audienceBackground: Excessive daytime sleepiness (EDS) in individuals with OSA syndrome persisting despite good adherence to CPAP is a disabling condition. Pitolisant is a selective histamine H3-receptor antagonist with wake-promoting effects.Research question: Is pitolisant effective and safe for reducing daytime sleepiness in individuals with moderate to severe OSA adhering to CPAP treatment but experiencing residual EDS?Study design and methods: In a multicenter, double-blind, randomized (3:1), placebo-controlled, parallel-design trial, pitolisant was titrated individually at up to 20 mg/day and taken over 12 weeks. The primary end point was change in the Epworth Sleepiness Scale (ESS) score in the intention-to-treat population. Key secondary end points were maintenance of wakefulness assessed by the Oxford Sleep Resistance Test, Clinical Global Impressions scale of severity, the patient's global opinion, EuroQoL quality-of-life questionnaire score, Pichot fatigue questionnaire score, and safety.Results: Two hundred forty-four OSA participants (82.8% men; mean age, 53.1 years; mean Apnea Hypopnea Index with CPAP, 4.2/h; baseline ESS score, 14.7) were randomized to pitolisant (n = 183) or placebo (n = 61). ESS significantly decreased with pitolisant compared with placebo (-2.6; 95% CI, -3.9 to -1.4; P < .001), and the rate of responders to therapy (ESS ≤ 10 or change in ESS ≥ 3) was significantly higher with pitolisant (71.0% vs 54.1%; P = .013). Adverse event occurrence (mainly headache and insomnia) was higher in the pitolisant group compared with the placebo group (47.0% and 32.8%, respectively; P = .03). No cardiovascular or other significant safety concerns were reported.Interpretation: Pitolisant used as adjunct to CPAP therapy for OSA with residual sleepiness despite good CPAP adherence significantly reduced subjective and objective sleepiness and improved participant-reported outcomes and physician-reported disease severity

    Documento internacional de consenso sobre apnea obstructiva del sueño.

    No full text
    The main aim of this international consensus document on obstructive sleep apnea is to provide guidelines based on a critical analysis of the latest literature to help health professionals make the best decisions in the care of adult patients with this disease. The expert working group was formed primarily of 17 scientific societies and 56 specialists from a wide geographical area (including the participation of 4 international societies), an expert in methodology, and a documentalist from the Iberoamerican Cochrane Center. The document consists of a main section containing the most significant innovations and a series of online manuscripts that report the systematic literature searches performed for each section of the international consensus document. This document does not discuss pediatric patients or the management of patients receiving chronic non-invasive mechanical ventilation (these topics will be addressed in separate consensus documents)
    corecore