944 research outputs found

    Catheter entrapment in a pulmonary vein: a unique complication of pulmonary vein isolation.

    Get PDF
    Ablation strategies for the treatment of atrial fibrillation (AF) are associated with several potential complications. During electro-anatomic mapping of the left atrium (LA) before ablation, the ablation catheter was entrapped in the right inferior pulmonary vein (RIPV). After multiple unsuccessful gentle tractions, stronger maneuvers with rotation of the catheter slowly allowed its retrieval. Examination of the catheter showed a thin, translucent membrane covering its tip, suggesting complete stripping of a vein branch. Occlusion of the superior branch of the RIPV was confirmed by LA angiogram. During the following days, no pericardial effusion was noted, but the patient complained of light chest pain and mild hemoptysis, spontaneously resolving within 48 h. This case shows that catheter entrapment and mechanical disruption of a PV branch can be a rare potential complication of AF ablation. In this case, the outcome was spontaneously favorable and symptoms only included transient mild hemoptysis

    Carotid Sinus Massage.

    Get PDF

    In vivo measurements of atrial repolarization alternans based on standard pacemaker technology

    Get PDF
    It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility

    Clinical determinants of the PR interval duration in Swiss middle-aged adults: The CoLaus/PsyCoLaus study.

    Get PDF
    Prolonged PR interval (PRi) is associated with adverse outcomes. However, PRi determinants are poorly known. We aimed to identify the clinical determinants of the PRi duration in the general population. Some clinical data are associated with prolonged PRi. Cross-sectional study conducted between 2014 and 2017. Electrocardiogram-derived PRi duration was categorized into normal or prolonged (>200 ms). Determinants were identified using stepwise logistic regression, and results were expressed as multivariable-adjusted odds ratio (OR) (95% confidence interval). A further analysis was performed adjusting for antiarrhythmic drugs, P-wave contribution to PRi duration, electrolytes (kalemia, calcemia, and magnesemia), and history of cardiovascular disease. Overall, 3655 participants with measurable PRi duration were included (55.6% females; mean age 62 ± 10 years), and 330 (9.0%) had prolonged PRi. Stepwise logistic regression identified male sex (OR 1.41 [1.02-1.97]); aging (65-74 years: OR 2.29 [1.61-3.24], and ≥ 75 years: OR 4.21 [2.81-6.31]); increased height (per 5 cm, OR 1.15 [1.06-1.25]); hypertension (OR 1.37 [1.06-1.77]); and hs troponin T (OR 1.67 [1.15-2.43]) as significantly and positively associated, and high resting heart rate (≥70 beats/min, OR 0.43 [0.29-0.62]) as negatively associated with prolonged PRi. After further adjustment, male sex, aging and increased height remained positively, and high resting heart rate negatively associated with prolonged PRi. Hypertension and hs troponin T were no longer associated. In a sample of the Swiss middle-aged population, male sex, aging and increased height significantly increased the likelihood of a prolonged PRi duration, whereas a high resting heart rate decreased it

    Predictive models of syncope causes in an outpatient clinic

    Get PDF
    The investigation of unexplained syncope remains a challenging clinical problem. In the present study we sought to evaluate the diagnostic value of a standardized work-up focusing on non invasive tests in patients with unexplained syncope referred to a syncope clinic, and whether certain combinations of clinical parameters are characteristic of rhythmic and reflex causes of syncope. METHODS AND RESULTS: 317 consecutive patients underwent a standardized work-up including a 12-lead ECG, physical examination, detailed history with screening for syncope-related symptoms using a structured questionnaire followed by carotid sinus massage (CSM), and head-up tilt test. Invasive testings including an electrophysiological study and implantation of a loop recorder were only performed in those with structural heart disease or traumatic syncope. Our work-up identified an etiology in 81% of the patients. Importantly, three quarters of the causes were established non invasively combining head-up tilt test, CSM and hyperventilation testing. Invasive tests yielded an additional 7% of diagnoses. Logistic analysis identified age and number of significant prodromes as the only predictive factors of rhythmic syncope. The same two factors, in addition to the duration of the ECG P-wave, were also predictive of vasovagal and psychogenic syncope. These factors, optimally combined in predictive models, showed a high negative and a modest positive predictive value. CONCLUSION: A standardized work-up focusing on non invasive tests allows to establish more than three quarters of syncope causes. Predictive models based on simple clinical parameters may help to distinguish between rhythmic and other causes of syncop
    corecore