209 research outputs found

    SplatArmor: Articulated Gaussian splatting for animatable humans from monocular RGB videos

    Full text link
    We propose SplatArmor, a novel approach for recovering detailed and animatable human models by `armoring' a parameterized body model with 3D Gaussians. Our approach represents the human as a set of 3D Gaussians within a canonical space, whose articulation is defined by extending the skinning of the underlying SMPL geometry to arbitrary locations in the canonical space. To account for pose-dependent effects, we introduce a SE(3) field, which allows us to capture both the location and anisotropy of the Gaussians. Furthermore, we propose the use of a neural color field to provide color regularization and 3D supervision for the precise positioning of these Gaussians. We show that Gaussian splatting provides an interesting alternative to neural rendering based methods by leverging a rasterization primitive without facing any of the non-differentiability and optimization challenges typically faced in such approaches. The rasterization paradigms allows us to leverage forward skinning, and does not suffer from the ambiguities associated with inverse skinning and warping. We show compelling results on the ZJU MoCap and People Snapshot datasets, which underscore the effectiveness of our method for controllable human synthesis

    The diet-derived short chain fatty acid propionate improves beta-cell function in humans and stimulates insulin secretion from human islets in vitro

    Get PDF
    Aims: Diet-derived short chain fatty acids (SCFAs) improve glucose homeostasis in vivo, but the role of individual SCFAs and their mechanisms of action have not been defined. This study evaluated the effects of increasing colonic delivery of the SCFA propionate on β-cell function in humans and the direct effects of propionate on isolated human islets in vitro. Materials and Methods: For 24 weeks human subjects ingested an inulin-propionate ester that delivers propionate to the colon. Acute insulin, GLP-1 and non-esterified fatty acid (NEFA) levels were quantified pre- and post-supplementation in response to a mixed meal test. Expression of the SCFA receptor FFAR2 in human islets was determined by western blotting and immunohistochemistry. Dynamic insulin secretion from perifused human islets was quantified by radioimmunoassay and islet apoptosis was determined by quantification of caspase 3/7 activities. Results: Colonic propionate delivery in vivo was associated with improved β-cell function with increased insulin secretion that was independent of changes in GLP-1 levels. Human islet β-cells expressed FFAR2 and propionate potentiated dynamic glucose-stimulated insulin secretion in vitro, an effect that was dependent on signalling via protein kinase C. Propionate also protected human islets from apoptosis induced by the NEFA sodium palmitate and inflammatory cytokines. Conclusions: Our results indicate that propionate has beneficial effects on β-cell function in vivo, and in vitro analyses demonstrated that it has direct effects to potentiate glucose-stimulated insulin release and maintain β-cell mass through inhibition of apoptosis. These observations support ingestion of propiogenic dietary fibres to maintain healthy glucose homeostasis

    Accuracy and Longevity of an Implantable Continuous Glucose Sensor in the PRECISE Study: A 180-Day, Prospective, Multicenter, Pivotal Trial

    Get PDF
    It is known that continuous glucose monitoring (CGM) systems can lower mean glucose compared with episodic self-monitoring of blood glucose. Implantable CGM systems may provide additional benefits. We studied the Eversense (Senseonics Inc.) implantable CGM sensor in 71 participants aged 18 years and older with type 1 and type 2 diabetes in a 180-day multinational, multicenter pivotal trial. Participants used the CGM system at home and in the clinic. CGM accuracy was assessed during eight in-clinic visits with the mean absolute relative difference (MARD) for venous reference glucose values >4.2 mmol/L as the primary end point. Secondary end points included Clarke Error Grid Analysis and alarm performance. The primary safety outcome was device-related serious adverse events. This trial is registered with ClinicalTrials.gov, number NCT02154126. The MARD value against reference glucose values >4.2 mmol/L was 11.1% (95% CI 10.5, 11.7). Clarke Error Grid Analysis showed 99.2% of samples in the clinically acceptable error zones A and B. Eighty-one percent of hypoglycemic events were detected by the CGM system within 30 min. No device-related serious adverse events occurred during the study. Our results indicate the safety and accuracy of this new type of implantable CGM system and support it as an alternative for transcutaneous CG

    Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk.

    Get PDF
    OBJECTIVE: To evaluate a sensor-augmented insulin pump with a low glucose suspend (LGS) feature that automatically suspends basal insulin delivery for up to 2 h in response to sensor-detected hypoglycemia. RESEARCH DESIGN AND METHODS: The LGS feature of the Paradigm Veo insulin pump (Medtronic, Inc., Northridge, CA) was tested for 3 weeks in 31 adults with type 1 diabetes. RESULTS: There were 166 episodes of LGS: 66% of daytime LGS episodes were terminated within 10 min, and 20 episodes lasted the maximum 2 h. LGS use was associated with reduced nocturnal duration ≤2.2 mmol/L in those in the highest quartile of nocturnal hypoglycemia at baseline (median 46.2 vs. 1.8 min/day, P = 0.02 [LGS-OFF vs. LGS-ON]). Median sensor glucose was 3.9 mmol/L after 2-h LGS and 8.2 mmol/L at 2 h after basal restart. CONCLUSIONS: Use of an insulin pump with LGS was associated with reduced nocturnal hypoglycemia in those at greatest risk and was well accepted by patients

    Characterization of pre-transplant psychosocial burden in an integrated national islet transplant programme

    Get PDF
    The psychological burden experienced by people with diabetes prior to islet transplantation is recognized but has not been studied comprehensively, especially in relation to glycemia. Therefore, we conducted a rigorous pre-operative psychosocial profile of UK islet transplant recipients, and compared groups with higher/lower HbA1 c to test the null hypothesis that pre-transplant hypoglycemia awareness and psychosocial burden would not be related to baseline HbA1 c in this high-risk cohort. Pre-transplant, recipients (n = 44) completed validated hypoglycemia awareness questionnaires and generic/diabetes-specific measures of psychological traits and states. Scores were compared in groups, dichotomized by HbA1 c (≤8% versus >8%). Participants were aged (mean±SD) 53 ± 10 years; 64% were women; with HbA1 c 8.3 ± 1.7%. Median rate of severe hypoglycemia over the preceding 12 months was 13 events/person-year and 90% had impaired awareness of hypoglycemia (Gold/Clarke score ≥4). Participants had elevated fear of hypoglycemia (HFS-II Worry), impaired diabetes-specific quality of life (DQoL) and low generic health status (SF-36; EQ-5D). One quarter reported scores indicating likely anxiety/depression (HAD). Dispositional optimism (LOT-R) and generalized self-efficacy (GSE) were within published ‘norms.’ Despite negative perceptions of diabetes (including low personal control), participants were confident that islet transplantation would help (BIPQ). Hypoglycemia awareness and psychosocial profile were comparable in lower (n = 24) and higher (n = 20) HbA1 c groups. Islet transplant candidates report sub-optimal generic psychological states (anxiety/depressive symptoms), health status and diabetes-specific psychological states (fear of hypoglycemia, diabetes-specific quality of life). While their generic psychological traits (optimism, self-efficacy) are comparable with the general population, they are highly optimistic about forthcoming transplant. HbA1 c is not a proxy measure of psychosocial burden, which requires the use of validated questionnaires to systematically identify those who may benefit most from psychological assessment and support

    Comparison of Optimised MDI versus Pumps with or without Sensors in Severe Hypoglycaemia (the Hypo COMPaSS trial).

    Get PDF
    BACKGROUND: Severe hypoglycaemia (SH) is one of the most feared complications of type 1 diabetes (T1DM) with a reported prevalence of nearly 40%. In randomized trials of Multiple Daily Injections (MDI) and Continuous Subcutaneous Insulin Infusion (CSII) therapy there is a possible benefit of CSII in reducing SH. However few trials have used basal insulin analogues as the basal insulin in the MDI group and individuals with established SH have often been excluded from prospective studies. In published studies investigating the effect of Real Time Continuous Glucose Monitoring (RT-CGM) benefit in terms of reduced SH has not yet been demonstrated. The primary objective of this study is to elucidate whether in people with T1DM complicated by impaired awareness of hypoglycaemia (IAH), rigorous prevention of biochemical hypoglycaemia using optimized existing self-management technology and educational support will restore awareness and reduce risk of recurrent SH. METHODS/DESIGN: This is a multicentre prospective RCT comparing hypoglycaemia avoidance with optimized MDI and CSII with or without RT-CGM in a 2×2 factorial design in people with type 1 diabetes who have IAH. The primary outcome measure for this study is the difference in IAH (Gold score) at 24 weeks. Secondary outcomes include biomedical measures such as HbA1c, SH incidence, blinded CGM analysis, self monitored blood glucose (SMBG) and response to hypoglycaemia in gold standard clamp studies. Psychosocial measures including well-being and quality of life will also be assessed using several validated and novel measures. Analysis will be on an intention-to-treat basis. DISCUSSION: Most existing RCTs using this study's interventions have been powered for change in HbA1c rather than IAH or SH. This trial will demonstrate whether IAH can be reversed and SH prevented in people with T1DM in even those at highest risk by using optimized conventional management and existing technology. TRIAL REGISTRATION: ISRCTN52164803 Eudract No: 2009-015396-27.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are

    Acceptability of Implantable Continuous Glucose Monitoring Sensor

    Get PDF
    Real-time continuous glucose monitoring is associated with significant benefits for diabetes management. Implantable sensors could overcome some challenges reportedly associated with device visibility, psychosocial functioning and sensor durability. A psychosocial assessment was conducted to determine acceptability and impact of an implantable continuous glucose monitoring (CGM) sensor as part of the PRECISE trial. Questionnaires were administered to participants comprising the Diabetes Distress Scale, the CGM impact scale, and bespoke device satisfaction. Fifty-one participants across the United Kingdom (n = 10) and Germany (n = 41) completed the questionnaires. Of these, 90% had T1D, 50% followed an insulin pump therapy regimen, and 45% of the participants were previous CGM users. CGM Impact Scale results show 86% (n = 44) of participants reported feeling better (14% neutral) about their diabetes control with 90% CGM naïve participants and 81% previous CGM users reporting increased confidence about their diabetes management. Furthermore, 73% (n = 37) felt more safe (27% neutral) while sleeping and 78% (n = 39) more confident (22% neutral) about avoiding serious hypoglycemia. Responses correspond with an average improvement in HbA1c from 7.51 to 7.05 ( P < .0001) over the 90 days use of the CGM. Overall, the system was rated highly on ease of use, convenience and comfort. 84% would choose to be inserted again with 93% of CGM naïve participants (86% previous CGM users) reporting minimized burden of diabetes. Implantable CGM devices are acceptable to users and are evaluated favorably. The considerable majority of participants (93% of first time users and 77% previous CGM users) would like to continue using the system to help manage their diabetes more effectivel

    UK's Association of British Clinical Diabetologist's Diabetes Technology Network (ABCD-DTN): Best practice guide for hybrid closed-loop therapy

    Get PDF
    This best practice guide is written with the aim of providing an overview of current hybrid closed-loop (HCL) systems in use within the United Kingdom's (UK) National Health Service (NHS) and to provide education and advice for their management on both an individual and clinical service level. The environment of diabetes technology, and particularly HCL systems, is rapidly evolving. The past decade has seen unprecedented advances in the development of HCL systems. These systems improve glycaemic outcomes and reduce the burden of treatment for people with type 1 diabetes (pwT1D). It is anticipated that access to these systems will increase in England as a result of updates in National Institute of Health and Care Excellence (NICE) guidance providing broader support for the use of real-time continuous glucose monitoring (CGM) for pwT1D. NICE are currently undertaking multiple-technology appraisal into HCL systems. Based on experience from centres involved in supporting advanced technologies as well as from the recent NHS HCL pilot, this guide is intended to provide healthcare professionals (HCPs) with UK expert consensus on the best practice for initiation, optimization and ongoing management of HCL therapy. [Abstract copyright: This article is protected by copyright. All rights reserved.

    The impact of islet mass, number of transplants, and time between transplants on graft function in a national islet transplant program

    Get PDF
    The UK islet allotransplant program is nationally funded to deliver one or two transplants over 12 months to individuals with type 1 diabetes and recurrent severe hypoglycemia. Analyses were undertaken 10 years after program inception to evaluate associations between transplanted mass; single versus two transplants; time between two transplants and graft survival (stimulated C-peptide >50 pmol/L) and function. In total, 84 islet transplant recipients were studied. Uninterrupted graft survival over 12 months was attained in 23 (68%) single and 47 (94%) (p =.002) two transplant recipients (separated by [median (IQR)] 6 (3–8) months). 64% recipients of one or two transplants with uninterrupted function at 12 months sustained graft function at 6 years. Total transplanted mass was associated with Mixed Meal Tolerance Test stimulated C-peptide at 12 months (p <.01). Despite 1.9-fold greater transplanted mass in recipients of two versus one islet infusion (12 218 [9291–15 417] vs. 6442 [5156–7639] IEQ/kg; p <.0001), stimulated C-peptide was not significantly higher. Shorter time between transplants was associated with greater insulin dose reduction at 12 months (beta −0.35; p =.02). Graft survival over the first 12 months was greater in recipients of two versus one islet transplant in the UK program, although function at 1 and 6 years was comparable. Minimizing the interval between 2 islet infusions may maximize cumulative impact on graft function

    Assessing the Content Validity, Acceptability, and Feasibility of the Hypo-METRICS App:Survey and Interview Study

    Get PDF
    Background: The Hypoglycaemia - MEasurement, ThResholds and ImpaCtS (Hypo-METRICS) smartphone app was developed to investigate the impact of hypoglycemia on daily functioning in adults with type 1 diabetes mellitus or insulin-treated type 2 diabetes mellitus. The app uses ecological momentary assessments, thereby minimizing recall bias and maximizing ecological validity. It was used in the Hypo-METRICS study, a European multicenter observational study wherein participants wore a blinded continuous glucose monitoring device and completed the app assessments 3 times daily for 70 days. Objective: The 3 aims of the study were to explore the content validity of the app, the acceptability and feasibility of using the app for the duration of the Hypo-METRICS study, and suggestions for future versions of the app. Methods: Participants who had completed the 70-day Hypo-METRICS study in the United Kingdom were invited to participate in a brief web-based survey and an interview (approximately 1h) to explore their experiences with the app during the Hypo-METRICS study. Thematic analysis of the qualitative data was conducted using both deductive and inductive methods. Results: A total of 18 adults with diabetes (type 1 diabetes: n=10, 56%; 5/10, 50% female; mean age 47, SD 16 years; type 2 diabetes: n=8, 44%; 2/8, 25% female; mean age 61, SD 9 years) filled out the survey and were interviewed. In exploring content validity, participants overall described the Hypo-METRICS app as relevant, understandable, and comprehensive. In total, 3 themes were derived: hypoglycemia symptoms and experiences are idiosyncratic; it was easy to select ratings on the app, but day-to-day changes were perceived as minimal; and instructions could be improved. Participants offered suggestions for changes or additional questions and functions that could increase engagement and improve content (such as providing more examples with the questions). In exploring acceptability and feasibility, 5 themes were derived: helping science and people with diabetes; easy to fit in, but more flexibility wanted; hypoglycemia delaying responses and increasing completion time; design, functionality, and customizability of the app; and limited change in awareness of symptoms and impact. Participants described using the app as a positive experience overall and as having a possible, although limited, intervention effect in terms of both hypoglycemia awareness and personal impact. Conclusions: The Hypo-METRICS app shows promise as a new research tool to assess the impact of hypoglycemia on an individual’s daily functioning. Despite suggested improvements, participants’ responses indicated that the app has satisfactory content validity, overall fits in with everyday life, and is suitable for a 10-week research study. Although developed for research purposes, real-time assessments may have clinical value for monitoring and reviewing hypoglycemia symptom awareness and personal impact.</p
    • …
    corecore