310 research outputs found

    RF spectroscopy in a resonant RF-dressed trap

    Full text link
    We study the spectroscopy of atoms dressed by a resonant radiofrequency (RF) field inside an inhomogeneous magnetic field and confined in the resulting adiabatic potential. The spectroscopic probe is a second, weak, RF field. The observed line shape is related to the temperature of the trapped cloud. We demonstrate evaporative cooling of the RF-dressed atoms by sweeping the frequency of the second RF field around the Rabi frequency of the dressing field.Comment: 7 figures, 8 pages; to appear in J. Phys.

    EXPERIMENTAL STUDY TO DETERMINE THE LOCAL CONDENSATION HEAT TRANSFER COEFFICIENTE FOR R134A FLOWING THROUGH A 4.8 MM INTERNAL DIAMETER SMOOTH HORIZONTAL TUBE

    Get PDF
    Refrigerant fluid R134a is commonly one of the most utilised invapour compression cycles wordlide, wheter in dommestic HVAC orautomotive regrigeration systems. This paper’s goal is toexperimetnally determine the fluid local condensation Heat TransferCoefficient (HTC), in several flor regimes. In this work, the mass fluxwas equal to 200, 250 and 300 kg/(m2s) and the fluid flowedthrough a smooth, horizontal 4.8 mm internal diameter aluminiumpipe, during which its vapour quality varied along the entire qualityrange. A purpose built test rig was developed, in which fluidconditions were constantly monitored and controlled. Throughmeasurements in temperature and pressure, an energy balance wasused to calculate experimentally the local heat transfer coeeficient.Average results for the unit quality range equalled to 3781 , 3459 and3944 W/m2K for saturation temperature equal to 30 C and theaforementioned mass velocities. Likewise, at 35C the averages HTCfound were 2903, 3141 and 3898 W/m2K at the same mass fluxrates. Later on, the experimental results were compared to tencommonly used HTC correlation found in relevant references,with Chato’s correlation returning the best fitting

    EXPERIMENTAL STUDY OF THE PRESSURE DROP OF THE ECOFLUID R1234YF COMPARED TO THE FLUID R134A IN SMOOTH TUBES WITH 4.8MM INTERNAL DIAMMETER

    Get PDF
    The refrigerant fluid R1234yf is a hydrofluorefine with zero potential for degradation of the ozone layer and low potential for global warming. It is one of the potential substitutes for the currently used R134a in automotive systems. In this work, the pressure drop suffered by the fluids R134a and R1234yf when flowing in a test section through a pipe with a 4.8 mm internal diameter was measured. The pressure drop was plotted as a function of the void fraction at the exit of the test section and the values were compared concerning the change in mass flux, change in saturation temperature, and comparatively between R1234yf and R134a. A significant increase in pressure drop was observed by the increases of the mass flux, showing an increment of 155.46% of the pressure loss from 200 to 300 kg·m-2·s-1 for R1234yf at 35ºC and 161.07% for R134a in the same conditions. Despite being high, those values are expected since increasing mass flux also increases the friction between both phases. On the other hand, by increasing the saturation temperature, the pressure drop is slightly lower once the differences between the densities of the liquid and vapor phases are reduced. Compared with R134a, the R1234yf ecofluid presents less pressure drop, showing a reduction of 24% for 300 kg·m-2·s-1

    AVERAGE TOTAL HEMISPHERIC EMISSIVITY MEASUREMENT IN THE LWIR SPECTRUM FOR ADHESIVE TAPES USED IN THE THERMOGRAPHY TAPE TEST

    Get PDF
    Thermographers often use comparative methods to estimate surfaceemissivity. Among the most used is the tape method. In this method a knownemissivity tape in the LWIR (Long Wavelength Infrared) spectrum is placedon the surface to be inspected. After thermal equilibrium, the temperature ofthe tape and the surface under inspection must be the same. In this case, thetemperature observed on the tape is the reference temperature. The emissivityof the surface must then be changed until the reference temperature isreached. It is common practice to admit the value of the emissivity of theadhesive tape as 0.95, there are few studies that present these data withmetrological rigor, which leads to doubts about the emissivity of thecommercial tapes. In this work, experiments were performed on Tekbond,Double A, 3M 101, Rapix, Altape, adhesive tapes for temperatures of 50, 55,60, 65 and 70ºC. An experimental apparatus was developed through which itwas possible to estimate surface reflection, transmission and atmosphericemission for one and two layers of tapes, in order to make emissivitymeasurements possible. Through the data it was possible to statisticallyestimate the LWIR average total hemispheric emissivity as well as theacceptance range to 95% certainty, being therefore equal to ε=0.94±0.03. Itis possible to arm, therefore, that the value of 0.95, usually used as emissivityof the adhesive tape, is extremely reasonable because it is 0.01 of the averagevalue of the Gaussian distribution calculated by this work

    EXPERIMENTAL STUDY OF A DOMESTIC SOLAR HEATER WITH IRON ORE AS THE ABSORBER

    Get PDF
    In Brazil's households, the use of electricity to heat water prevails, but its replacement by solar collectors can be justified due to the country's high level of solar radiation, average temperature and number of sunny days. A drawback preventing the broad spread of this technology its elevated inicial cost that, in spite of the short return on investment time, hinders its insertions on the population lower classes. Thereby, this study's goal is to search a cheaper alternative to one of the collector's most expensive component, by proposing the replacement of the aluminium sheets, used as absorber, by iron ore. This material was chosen due to its abundance in Minas Gerais, low cost and for being dark colored, ensuring high levels of absortance (0,4 < λ< 0,7 µm). A finely grained hematitic () ore was used to achieve an uniform compaction throughout its area, reducing this way, the thermal contact resistance between the absorber and the copper tubes. The collector was built and tested in similar conditions it would have faced during its lifespan, and the result shows that the maximum thermal efficiency was 58%