1,278 research outputs found

    Tailored virtual reality and mobile application for motor rehabilitation

    Get PDF
    The present work presents a measurement system and methodology for hand and finger motor rehabilitation. The interaction with serious games developed in Unity 3D game engine is performed using a natural user interface based on Leap Motion Controller. The storage and management of data related to patient identification, established training plans and training results in LeaPhysio system, is realized in a client server architecture. The stored information can be accessed through a developed LeaPhysio App for Android OS platform, which also allows configuration of training plan by a therapist. Different metrics were included in the measurement system to provide to users the possibility to evaluate in an objective way the motor rehabilitation. The tests have shown that the developed system can provide accurate data on hand and finger movements in a meaningful and motivating exercise environment.info:eu-repo/semantics/acceptedVersio

    Wrist and hand rehabilitation software platform based on leap motion controller

    Get PDF
    A software platform based on Leap Motion Controller (LMC) movements’ detection was developed. It allows measurements of clinically proved effective hand and finger exercises. The developed software allows representation of amplitude of each different movement, time interval for each movement, frequency of different movements, asymmetry of bilateral movements, standard deviation of signal amplitude, Poincaré plots. A serious game Collect Color Cube, was developed using Unity, C# scrips, and signals from LMC related to movements of the user’s hands and fingers.info:eu-repo/semantics/publishedVersio

    Exergames for motor rehabilitation in older adults: an umbrella review

    Get PDF
    Background: Exergames have been used as an innovative motor rehabilitation method with the main aim of improving motivation and exercise. As research interest in exergaming for rehabilitation is rapidly growing, a review of existing systematic reviews is important to synthesize the available evidence and provide recommendations. Objectives: In this article, we systematically synthesized the information from reviews that have examined the effects if exergames on different body movement parameters in older adults with and without specific pathologies. Method: Searches were conducted in Web of Science, Scopus, PsycARTICLES, PsycINFO, Psychology and Behavioural Sciences Collection, PubMed, SciELO, B-On and Google Scholar, articulating different terms and Boolean operators. Systematic reviews, meta-analysis and literature reviews published until May 2017 that investigated exergame interventions on physical outcomes, such as balance, gait, limb movements, muscle strength, in healthy and non-healthy older adults. Results: Based on prior reviews, exergaming, as a standalone intervention, has a positive effect on balance, gait, muscle strength, upper limb function, and dexterity. When compared to traditional physiotherapy, exergaming has at least similar effects on these outcomes. Many of the investigated studies indicated low methodological quality for the evaluation of the effects of exergames on different outcomes related to motor rehabilitation. Conclusions: Exergames could be used as a complement to traditional forms of motor rehabilitation, but future individual studies and reviews should follow more rigorous methodological standards in order to improve the quality of the evidence and provide guidelines for the use of exergames in motor rehabilitation.info:eu-repo/semantics/acceptedVersio

    AI-based smart sensing and AR for gait rehabilitation assessment

    Get PDF
    Health monitoring is crucial in hospitals and rehabilitation centers. Challenges can affect the reliability and accuracy of health data. Human error, patient compliance concerns, time, money, technology, and environmental factors might cause these issues. In order to improve patient care, healthcare providers must address these challenges. We propose a non-intrusive smart sensing system that uses a SensFloor smart carpet and an inertial measurement unit (IMU) wearable sensor on the user’s back to monitor position and gait characteristics. Furthermore, we implemented machine learning (ML) algorithms to analyze the data collected from the SensFloor and IMU sensors. The system generates real-time data that are stored in the cloud and are accessible to physical therapists and patients. Additionally, the system’s real-time dashboards provide a comprehensive analysis of the user’s gait and balance, enabling personalized training plans with tailored exercises and better rehabilitation outcomes. Using non-invasive smart sensing technology, our proposed solution enables healthcare facilities to monitor patients’ health and enhance their physical rehabilitation plans.info:eu-repo/semantics/publishedVersio

    Analysis of the Steinmetz compensation circuit with distorted waveforms through symmetrical component-based indicators

    Get PDF
    This paper deals with the use of a set of indicators defined within a symmetrical component-based framework to study the characteristics of the Steinmetz compensation circuit in the presence of waveform distortion. The Steinmetz circuit is applied to obtain balanced currents in a three-phase system supplying a single-phase load. The circuit is analyzed without and with harmonic distortion of the supply voltages. The compensation effect is represented by the classical unbalance factor and by the Total Phase Unbalance (TPU) indicator defined in the symmetrical component-based framework. Comparing the two indicators, it is shown that the classical unbalance factor is insufficient to represent the effect of voltage distortion and fails to detect the lack of total unbalance compensation occurring with distorted waveforms. Correct information is provided by calculating the TPU indicator. © 2009 IEEE

    Effects of Vagal Stimulation on Induction and Termination of Atrial Fibrillation in an in Vivo Rabbit Heart Model

    Get PDF
    INTRODUCTION: Vagal activity is thought to influence atrial electrophysiological properties and play a role in the initiation and maintenance of atrial fibrillation (AF). In this study, we assessed the effects of acute vagal stimulation (vagus_stim) on atrial conduction times, atrial and pulmonary vein (PV) refractoriness, and vulnerability to induction of AF in the rabbit heart with intact autonomic innervation. METHODS: An open-chest epicardial approach was performed in 11 rabbits (New Zealand; 3.9-5.0 kg), anesthetized and artificially ventilated after neuromuscular blockade. A 3-lead ECG was obtained. Atrial electrograms were recorded along the atria, from right to left (four monopolar electrodes), together with a circular electrode adapted for proximal left PV assessment. Acute vagus nerve stimulation was obtained with bipolar electrodes (20 Hz). Epicardial activation was recorded in sinus rhythm, and the conduction time from right (RA) to left atrium (LA), and from RA to PVs, was measured in basal conditions and during vagus_stim. The atrial effective refractory period (ERP) and dispersion of refractoriness (Disp_A) were analyzed. Vulnerability to AF induction was assessed at the right (RAA) and left (LAA) atrial appendages and the PVs. Atrial stimulation (50 Hz) was performed alone or combined with vagus_stim. Heart rate and blood pressure were monitored. RESULTS: In basal conditions, there was a significant delay in conduction from RA to PVs, not influenced by vagus_stim, and the PV ERPs were shorter than those measured in LA and LAA, but without significant differences compared to RA and RAA. During vagus_stim, conduction times between RA and LA increased from 16+8 ms to 27+6 ms (p 10 s in 45.4% of rabbits during vagus_stim, and ceased after vagus_stim in 4 out of these 5 cases. In 3 animals, PV tachycardia, with fibrillatory conduction, induced with 50 Hz PV pacing during vagus_stim. CONCLUSIONS: Vagus_stim reduces interatrial conduction velocity and significantly shortens atrial ERP, contributing to the induction and duration of AF episodes in the in vivo rabbit heart. This model may be useful for the assessment of autonomic influence on the pathophysiology of AF

    A pulsed nanosecond IR laser diode system to automatically test the Single Event Effects in the laboratory

    Get PDF
    Abstract A pulsed nanosecond IR laser diode system to automatically test the Single Event Effects in laboratory is described. The results of Single Event Latchup (SEL) test on two VLSI chips (VA_HDR64, 0.8 and 1.2 μm technology) are discussed and compared to those obtained with high-energy heavy ions at GSI (Darmstadt)

    Measurements and tests on FBK silicon sensors with an optimized electronic design for a CTA camera

    Full text link
    In October 2013, the Italian Ministry approved the funding of a Research & Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made in Italy (TECHE)", devoted to the development of a demonstrator for a camera for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on an electronics designed for signal sampling. Preliminary tests on a matrix of sensors produced by the Fondazione Bruno Kessler (FBK-Trento, Italy) and on electronic prototypes produced by SITAEL S.p.A. will be presented. In particular, we used different designs of the electronics in order to optimize the output signals in terms of tail cancellation. This is crucial for applications where a high background is expected, as for the CTA experiment.Comment: 5 pages, 6 figures; Proceedings of the 10th Workshop on Science with the New Generation of High-Energy Gamma-ray experiments (SciNeGHE) - PoS(Scineghe2014)00
    • …
    corecore