140 research outputs found

    Modelling of influential parameters on a continuous evaporation process by Doehlert shells

    Get PDF
    The modelling of the parameters that influence the continuous evaporation of an alcoholic extract was considered using Doehlert matrices. The work was performed with a wiped falling film evaporator that allowed us to study the influence of the pressure, temperature, feed flow and dry matter of the feed solution on the dry matter contents of the resulting concentrate, and the productivity of the process. The Doehlert shells were used to model the influential parameters. The pattern obtained from the experimental results was checked allowing for some dysfunction in the unit. The evaporator was modified and a new model applied; the experimental results were then in agreement with the equations. The model was finally determined and successfully checked in order to obtain an 8% dry matter concentrate with the best productivity; the results fit in with the industrial constraints of subsequent processes

    Optimization and evaluation in space conditions of multi-GHz optical modulators

    Get PDF
    Among the different optical modulator technologies available such as polymer, III-V semiconductors, Silicon, the well-known Lithium Niobate (LN) offers the best trade-off in terms of performances, ease of use, and power handling capability [1-9]. The LN technology is still widely deployed within the current high data rate fibre optic communications networks. This technology is also the most mature and guarantees the reliability which is required for space applications [9].In or der to fulfil the target specifications of opto-microwave payloads, an optimization of the design of a Mach-Zehnder (MZ) modulator working at the 1500nm telecom wavelength was performed in the frame of the ESA-ARTES "Multi GigaHertz Optical Modulator" (MGOM) project in order to reach ultra-low optical insertion loss and low effective driving voltage in the Ka band. The selected modulator configuration was the X-cut crystal orientation, associated to high stability Titanium in-diffusion process for the optical waveguide. Starting from an initial modulator configuration exhibiting 9 V drive voltage @ 30 GHz, a complete redesign of the coplanar microwave electrodes was carried out in order to reach a 6 V drive voltage @ 30GHz version. This redesign was associated to an optimization of the interaction between the optical waveguide and the electrodes. Following the optimisation steps, an evaluation program was applied on a lot of 8 identical modulators. A full characterisation was carried out to compare performances, showing small variations between the initial and final functional characteristics. In parallel, two similar modulators were submitted to both gamma (10-100 krad) and proton irradiation (10.109 p/cm²) with minor performance degradation

    Removal of lead (II) ions from synthetic and real effluents using immobilized Pinus sylvestris sawdust: Adsorption on a fixed bed column,

    Get PDF
    Abstract The purpose of this work was to evaluate the potential of Pinus sylvestris sawdust, in a continuous flow removal of lead (II) ions from synthetic and industrial aqueous effluents. The kinetic parameters obtained in a batch process were used to scale-up the process on a minicolumn and to choose the breakthrough model. The column experimental data concerning the volumes treated were correlated using the bed depth service time model. These experimental data closely fitted the bed depth service time model at 10% of the breakthrough curve. The results from the bed depth service time model on the mini-column were then used to design a pilot plant adsorption unit. The performance of the pilot plant column accurately agreed with that obtained from the mini-column. The experiments carried out in a dynamic reactor allowed to bring out the influence of various parameters on the efficiency of the P. sylvestris sawdust. In addition, the process was checked for the treatment of industrial aqueous effluents on a pilot plant scale and the results were in accordance with those obtained from synthetic effluents

    A Comparative Study of Single and Dual Perfusion During End-ischemic Subnormothermic Liver Machine Preservation

    Get PDF
    Background: It remains controversial if arterial perfusion in addition to portal vein perfusion during machine preservation improves liver graft quality. Comparative studies using both techniques are lacking. We studied the impact of using single or dual machine perfusion of donation after circulatory death rat livers. In addition, we analyzed the effect of pulsatile versus continuous arterial flow. Methods: Donation after circulatory death rat livers (n = 18) were preserved by 6 hours cold storage, followed by 1 hour subnormothermic machine perfusion (20 degrees C, pressure of 40/5 mm Hg) and 2 hours ex vivo warm reperfusion (37 degrees C, pressure of 80/11 mm Hg, 9% whole blood). Machine preservation was either through single portal vein perfusion (SP), dual pulsatile (DPP), or dual continuous perfusion (DCP) of the portal vein and hepatic artery. Hydrodynamics, liver function tests, histopathology, and expression of endothelial specific genes were assessed during 2 hours warm reperfusion. Results: At the end of reperfusion, arterial flow in DPP livers tended to be higher compared to DCP and SP grafts. However, this difference was not significant nor was better flow associated with better outcome. No differences in bile production or alanine aminotransferase levels were observed. SP livers had significantly lower lactate compared to DCP, but not DPP livers. Levels of Caspase-3 and tumor necrosis factor-alpha were similar between the groups. Expression of endothelial genes Kruppel-like-factor 2 and endothelial nitric oxide synthase tended to be higher in dual perfused livers, but no histological evidence of better preservation of the biliary endothelium or vasculature of the hepatic artery was observed. Conclusions: This study shows comparable outcomes after using a dual or single perfusion approach during end-ischemic subnormothermic liver machine preservation

    Metformin Preconditioning Improves Hepatobiliary Function and Reduces Injury in a Rat Model of Normothermic Machine Perfusion and Orthotopic Transplantation

    Get PDF
    Background. Preconditioning of donor livers before organ retrieval may improve organ quality after transplantation. We investigated whether preconditioning with metformin reduces preservation injury and improves hepatobiliary function in rat donor livers during ex situ normothermic machine perfusion (NMP) and after orthotopic liver transplantation. Methods. Lewis rats were administered metformin via oral gavage, after which a donor hepatectomy was performed followed by a standardized cold storage period of 4 hours. Graft assessment was performed using NMP via double perfusion of the hepatic artery and portal vein. In an additional experiment, rat donor livers preconditioned with metformin were stored on ice for 4 hours and transplanted to confirm postoperative liver function and survival. Data were analyzed and compared with sham-fed controls. Results. Graft assessment using NMP confirmed that preconditioning significantly improved ATP production, markers for hepatobiliary function (total bile production, biliary bilirubin, and bicarbonate), and significantly lowered levels of lactate, glucose, and apoptosis. After orthotopic liver transplantation, metformin preconditioning significantly reduced transaminase levels. Conclusions. Preconditioning with metformin lowers hepatobiliary injury and improves hepatobiliary function in an in situ and ex situ model of rat donor liver transplantation

    Hypothermic Oxygenated Machine Perfusion Prevents Arteriolonecrosis of the Peribiliary Plexus in Pig Livers Donated after Circulatory Death

    Get PDF
    BACKGROUND: Livers derived from donation after circulatory death (DCD) are increasingly accepted for transplantation. However, DCD livers suffer additional donor warm ischemia, leading to biliary injury and more biliary complications after transplantation. It is unknown whether oxygenated machine perfusion results in better preservation of biliary epithelium and the peribiliary vasculature. We compared oxygenated hypothermic machine perfusion (HMP) with static cold storage (SCS) in a porcine DCD model. METHODS: After 30 min of cardiac arrest, livers were perfused in situ with HTK solution (4°C) and preserved for 4 h by either SCS (n = 9) or oxygenated HMP (10°C; n = 9), using pressure-controlled arterial and portal venous perfusion. To simulate transplantation, livers were reperfused ex vivo at 37°C with oxygenated autologous blood. Bile duct injury and function were determined by biochemical and molecular markers, and a systematic histological scoring system. RESULTS: After reperfusion, arterial flow was higher in the HMP group, compared to SCS (251±28 vs 166±28 mL/min, respectively, after 1 hour of reperfusion; p = 0.003). Release of hepatocellular enzymes was significantly higher in the SCS group. Markers of biliary epithelial injury (biliary LDH, gamma-GT) and function (biliary pH and bicarbonate, and biliary transporter expression) were similar in the two groups. However, histology of bile ducts revealed significantly less arteriolonecrosis of the peribiliary vascular plexus in HMP preserved livers (>50% arteriolonecrosis was observed in 7 bile ducts of the SCS preserved livers versus only 1 bile duct of the HMP preserved livers; p = 0.024). CONCLUSIONS: Oxygenated HMP prevents arteriolonecrosis of the peribiliary vascular plexus of the bile ducts of DCD pig livers and results in higher arterial flow after reperfusion. Together this may contribute to better perfusion of the bile ducts, providing a potential advantage in the post-ischemic recovery of bile ducts

    Criteria for Viability Assessment of Discarded Human Donor Livers during Ex Vivo Normothermic Machine Perfusion

    Get PDF
    Although normothermic machine perfusion of donor livers may allow assessment of graft viability prior to transplantation, there are currently no data on what would be a good parameter of graft viability. To determine whether bile production is a suitable biomarker that can be used to discriminate viable from non-viable livers we have studied functional performance as well as biochemical and histological evidence of hepatobiliary injury during ex vivo normothermic machine perfusion of human donor livers. After a median duration of cold storage of 6.5 h, twelve extended criteria human donor livers that were declined for transplantation were ex vivo perfused for 6 h at 37 °C with an oxygenated solution based on red blood cells and plasma, using pressure controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion. During perfusion, two patterns of bile flow were identified: (1) steadily increasing bile production, resulting in a cumulative output of ≥ 30 g after 6 h (high bile output group), and (2) a cumulative bile production <20 g in 6 h (low bile output group). Concentrations of transaminases and potassium in the perfusion fluid were significantly higher in the low bile output group, compared to the high bile output group. Biliary concentrations of bilirubin and bicarbonate were respectively 4 times and 2 times higher in the high bile output group. Livers in the low bile output group displayed more signs of hepatic necrosis and venous congestion, compared to the high bile output group. In conclusion, bile production could be an easily assessable biomarker of hepatic viability during ex vivo machine perfusion of human donor livers. It could potentially be used to identify extended criteria livers that are suitable for transplantation. These ex vivo findings need to be confirmed in a transplant experiment or a clinical trial

    Rationale and design of TransplantLines:a prospective cohort study and biobank of solid organ transplant recipients

    Get PDF
    Introduction In the past decades, short-term results after solid organ transplantation have markedly improved. Disappointingly, this has not been accompanied by parallel improvements in long-term outcomes after transplantation. To improve graft and recipient outcomes, identification of potentially modifiable risk factors and development of biomarkers are required. We provide the rationale and design of a large prospective cohort study of solid organ transplant recipients (TransplantLines). Methods and analysis TransplantLines is designed as a single-centre, prospective cohort study and biobank including all different types of solid organ transplant recipients as well as living organ donors. Data will be collected from transplant candidates before transplantation, during transplantation, at 3 months, 6 months, 1 year, 2 years and 5 years, and subsequently every 5 years after transplantation. Data from living organ donors will be collected before donation, during donation, at 3 months, 1 year and 5 years after donation, and subsequently every 5 years. The primary outcomes are mortality and graft failure. The secondary outcomes will be cause-specific mortality, cause-specific graft failure and rejection. The tertiary outcomes will be other health problems, including diabetes, obesity, hypertension, hypercholesterolaemia and cardiovascular disease, and disturbances that relate to quality of life, that is, physical and psychological functioning, including quality of sleep, and neurological problems such as tremor and polyneuropathy. Ethics and dissemination Ethical approval has been obtained from the relevant local ethics committee. The TransplantLines cohort study is designed to deliver pioneering insights into transplantation and donation outcomes. The study design allows comprehensive data collection on perioperative care, nutrition, social and psychological functioning, and biochemical parameters. This may provide a rationale for future intervention strategies to more individualised, patient-centred transplant care and individualisation of treatment

    Proton Pump Inhibitor Use, Fatigue, and Health-Related Quality of Life in Kidney Transplant Recipients:Results From the TransplantLines Biobank and Cohort Study

    Get PDF
    Rationale &amp; Objective: Prior studies report that the use of proton pump inhibitors (PPIs) can adversely affect gut microbiota and gastrointestinal uptake of micronutrients, in particular iron and magnesium, and are used frequently by kidney transplant recipients. Altered gut microbiota, iron deficiency, and magnesium deficiency have been implicated in the pathogenesis of chronic fatigue. Therefore, we hypothesized that PPI use may be an important and underappreciated cause of fatigue and reduced health-related quality of life (HRQoL) in this population. Study Design: Cross-sectional study. Setting &amp; Participants: Kidney transplant recipients (≥1 year after transplantation) enrolled in the TransplantLines Biobank and Cohort Study. Exposure: PPI use, PPI type, PPI dosage, and duration of PPI use. Outcome: Fatigue and HRQoL, assessed using the validated Checklist Individual Strength 20 Revised questionnaire and Short Form-36 questionnaire. Analytical Approach: Logistic and linear regression. Results: We included 937 kidney transplant recipients (mean age 56 ± 13 years, 39% female) at a median of 3 (1-10) years after transplantation. PPI use was associated with fatigue severity (regression coefficient 4.02, 95% CI, 2.18 to 5.85, P &lt; 0.001), a higher risk of severe fatigue (OR 2.05, 95% CI, 1.48 to 2.84, P &lt; 0.001), lower physical HRQoL (regression coefficient −8.54, 95% CI, −11.54 to −5.54, P &lt; 0.001), and lower mental HRQoL (regression coefficient −4.66, 95% CI, −7.15 to −2.17, P &lt; 0.001). These associations were independent of potential confounders including age, time since transplantation, history of upper gastrointestinal disease, antiplatelet therapy, and the total number of medications. They were present among all individually assessed PPI types and were dose dependent. Duration of PPI exposure was only associated with fatigue severity. Limitations: Residual confounding and inability to assess causal relationships. Conclusions: PPI use is independently associated with fatigue and lower HRQoL among kidney transplant recipients. PPI use might be an easily accessible target for alleviating fatigue and improving HRQoL among kidney transplant recipients. Further studies examining the effect of PPI exposure in this population are warranted. Plain-Language Summary: In this observational study, we investigated the association of proton pump inhibitors with fatigue and health-related quality of life among kidney transplant recipients. Our data showed that proton pump inhibitors were independently associated with fatigue severity, severe fatigue, and lower physical and mental health-related quality of life. These associations were present among all individually assessed proton pump inhibitor types and were dose dependent. While we await future studies on this topic, proton pump inhibitor use might be an easily accessible target for alleviating fatigue and improving health-related quality of life among kidney transplant recipients.</p

    Investigation of intrinsic defects and versatility of Zn-doping in SnO2 thin films using pulsed laser deposition

    Get PDF
    n-type transparent conducting oxides (TCOs) have been studied extensively and are now commercially available. The development of p-type counterparts lags someway behind, despite the opportunity preparing such materials offers. Interest in tin oxide (SnO2) thin films and their applications has grown significantly over recent years, particularly for the preparation of p-type TCOs. However for this to be realised, limitations such as the ionisation energy of acceptor defects and the existence of compensating mechanisms must be overcome. Even though the effectiveness of acceptor doping is essential, the presence of compensating defects as the film growth environment changes is critical for stable p-type TCOs. Here a growth study of SnO2 deposited using pulsed laser deposition (PLD) reveals intrinsic acceptor defects have limited contribution to the conductivity as theoretically predicted. The conductivity remains n-type despite significant variation in the oxygen content of the growth environment and temperature - which is attributed to the large concentration of tin interstitial defects. To limit donor defect concentration, elevated temperature and oxygen pressure were set as the growth conditions with the introduction of Zn as an acceptor dopant. Here, the introduction of Zn acceptors changes the behaviour of intrinsic defects such that measured charge carrier concentrations increase by some 3-orders of magnitude compared with undoped films, suggesting the presence of compensating mechanisms. n-type behaviour persists, even after oxygen annealing, and film resistivity also increases. This is attributed to the formation more acceptor defects that act as electron compensation centres. Zn is reported to act not only as an acceptor in SnO2 but also to enhance n-type conductivity: here this behaviour is also confirmed. By studying the electrical, optical and structural properties of Zn doped SnO2, films of surprisingly low resistivity (2.9 x10-3 Ω.cm) were formed, which exhibited preferential (200) on Zn addition. An observed decrease in bandgap was found when Zn doping was increased, from 3.6 eV in undoped films down to 3.4 eV in crystalline films and 3.2 eV in amorphous films. The work is concluded by investigating low deposition temperature where low resistivity highly transparent films are formed at temperatures as low as 100 degree celcius.Open Acces
    • …
    corecore