177 research outputs found

    WISER Deliverable D3.3-2: The importance of invertebrate spatial and temporal variation for ecological status classification for European lakes

    Get PDF
    European lakes are affected by many human induced disturbances. In principle, ecological theories predict that the structure and functioning of benthic invertebrate assemblage (one of the Biological Quality Elements following the Water Framework Directive, WFD terminology) change in response to the level of disturbances, making this biological element suitable for assessing the status and management of lake ecosystems. In practice, to set up assessment systems based on invertebrates, we need to distiguish community changes that are related to human pressures from those that are inherent natural variability. This task is complicated by the fact that invertebrate communities inhabiting the littoral and the profundal zones of lakes are constrained by different factors and respond unevenly to distinct human disturbances. For example it is not clear yet how the invertebrates assemblages respond to watershed and shoreline alterations, nor the relative importance of spatial and temporal factors on assemblage dynamics and relative bioindicator values of taxa, the habitat constraints on species traits and other taxonomic and methodological limitations. The current lack of knowledge of basic features of invertebrate temporal and spatial variations is limiting the fulfillment of the EU-wide intercalibration of lake ecological quality assessment systems in Europe, and thus compromising the basis for setting the environmental objectives as required by the WFD. The aim of this deliverable is to provide a contribution towards the understanding of basic sources of spatial and temporal variation of lake invertebrate assemblages. The report is structured around selected case studies, manly involving the analysis of existing datasets collated within WISER. The case studies come from different European lake types in the Northern, Central, Alpine and Mediterranean regions. All chapters have an obvious applied objective and our aim is to provide to those dealing with WFD implementation at various levels useful information to consider when designing monitoring programs and / or invertebrate-based classification systems

    Physics-Based Mixed-Mode Reverse Recovery Modeling And Optimization Of Si PiN And MPS Fast Recovery Diodes

    Get PDF
    The paper presents the results of the application of physics-based mixed-mode simulations to the analysis and optimization of the reverse recovery for Si-based fast recovery diodes (FREDs) using Platinum (Pt) lifetime killing. The trap model parameters are extracted from Deep Level Transient Spectroscopy (DLTS) characterization. The model is validated against experimental characterization carried out on the current International Rectifier (IR) FRED PiN technology. Improved designs, using emitter control efficiency and merged PiN-Schottky structures, are analyzed. Comparison between simulated and measured results are presente

    Translocal social resilience dimensions of migration as adaptation to environmental change

    Get PDF
    There is growing recognition of the potential of migration to contribute to climate-change adaptation. Yet, there is limited evidence to what degree, under what conditions, for whom, and with which limitations this is effectively the case. We argue that this results from a lack of recognition and systematic incorporation of sociospatiality—the nested, networked, and intersectional nature of migration-as-adaptation. Our central objective is to utilize the translocal social-resilience approach to overcome these gaps, to identify processes and structures that shape the social resilience of translocal livelihood systems, and to illustrate the mechanisms behind the multiplicity of possible resilience outcomes. Translocal livelihood constellations anchored in rural Thailand as well as in domestic and international destinations of Thai migrants serve as illustrative empirical cases. Data were gathered through a multisited and mixed-methods research design. This paper highlights the role of the distinct but interlinked situations and operational logics at places of origin and destination, as well as the different positionalities and resulting vulnerabilities, roles, commitments, and practices of individuals and households with regard to resilience. Based on the empirical results, the paper distills a generalized typology of five broad categories of resilience outcomes, which explicitly considers sociospatiality. Our approach helps to grasp the complexity of migration-as-adaptation and to avoid simplistic conclusions about the benefits and costs of migration for adaptation—both of which are necessary for sound, evidence-based, migration-as-adaptation policymaking

    Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163^{163}Ho ions

    Full text link
    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163^{163}Ho using MMCs having the radioactive 163^{163}Ho ions implanted in the absorber. The implantation of 163^{163}Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. In addition an optimized detector design for future 163^{163}Ho experiments is presented

    Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

    Get PDF
    Like MMCs, MPTs enable high energy microcalorimeters with zero bias power dissipation and potential resolution < 1 eV. MPTs can provide d(phi)/dT as large as 1000 (Phi)(sub 0)/K, with no excess noise, thereby reducing the importance of SQUID noise. Long coherence length in a Type-I superconducting MoAu film offers multiple advantages for efficient flux expulsion in MPT. Region of steepest d(phi)/dT is the Meissner effect in the small device; flux is expelled/penetrates to minimize free energy. Steepness of transition can be engineered with choice of film thickness and coil pitch relative to lambda(sub eff)(0), ratio of T/T(sub c), and bias circuit inductance

    The Magnetically-Tuned Transition-Edge Sensor

    Get PDF
    We present the first measurements on the proposed magnetically-tuned superconducting transition-edge sensor (MTES) and compare the modified resistive transition with the theoretical prediction. A TES's resistive transition is customarily characterized in terms of the unit less device parameters alpha and beta corresponding to the resistive response to changes in temperature and current respectively. We present a new relationship between measured IV quantities and the parameters alpha and beta and use these relations to confirm we have stably biased a TES with negative beta parameter with magnetic tuning. Motivated by access to this new unexplored parameter space, we investigate the conditions for bias stability of a TES taking into account both self and externally applied magnetic fields

    Hardness, function, emotional well-being, satisfaction and the overall sexual experience in men using 100-mg fixed-dose or flexible-dose sildenafil citrate

    Get PDF
    The prescribing information for sildenafil citrate (VIAGRA, Pfizer, New York, NY, USA) recommends flexible dosing (50 mg initially, adjusted to 100 or 25 mg based on effectiveness and tolerability) in most men with erectile dysfunction (ED). In many men, however, 100 mg may be the most appropriate initial dose because it would reduce the need for titration and could prevent discouragement and treatment abandonment should 50 mg be insufficient. Results of two previously published double-blind, placebo-controlled sildenafil trials of similar design except for a fixed-dose vs flexible-dose regimen were analyzed. Relative to the flexible-dose, approximately one-third more men were satisfied with an initial and fixed dose of 100 mg. In addition, tolerability was similar, and improvements from baseline in outcomes on validated, ED-specific, patient-reported questionnaires were either similar (erectile function and the percentage of completely hard and fully rigid erections) or greater (emotional well-being and the overall sexual experience). The similarity in outcomes is not surprising given that almost 90% of the men in the flexible-dose trial titrated to 100 mg after 2 weeks. These data suggest prescription of an initial dose of 100 mg for men with ED, except in those for whom it is inappropriate

    Indirect comparison of interventions using published randomised trials: systematic review of PDE-5 inhibitors for erectile dysfunction

    Get PDF
    BACKGROUND: There are no randomised and properly blinded trials directly comparing one PDE-5 inhibitor with another in a normal home setting. Valid indirect comparisons with a common comparator must examine equivalent doses, similar duration, similar populations, with the same outcomes reported in the same way. METHODS: Published randomised, double-blind trials of oral PDE-5 inhibitors for erectile dysfunction were sought from reference lists in previous reviews and electronic searching. Analyses of efficacy and harm were carried out for each treatment, and results compared where there was a common comparator and consistency of outcome reporting, using equivalent doses. RESULTS: Analysis was limited by differential reporting of outcomes. Sildenafil trials were clinically and geographically more diverse. Tadalafil and vardenafil trials tended to use enriched enrolment. Using all trials, the three interventions were similar for consistently reported efficacy outcomes. Rates of successful intercourse for sildenafil, tadalafil and vardenafil were 65%, 62%, and 59%, with placebo rates of 23–28%. The rates of improved erections were 76%, 75% and 71%, respectively, with placebo rates of 22–24%, and NNTs of 1.9 or 2.0. Reporting of withdrawals was less consistent, but all-cause withdrawals for sildenafil, tadalafil and vardenafil were 8% 13% and 20%. All three drugs were well tolerated, with headache being the most commonly reported event at 13–17%. There were few serious adverse events. CONCLUSION: There were differences between trials in outcomes reported, limiting comparisons, and the most useful outcomes were not reported. For common outcomes there was similar efficacy between PDE-5 inhibitors

    Development of Kilo-Pixel Arrays of Transition-Edge Sensors for X-Ray Spectroscopy

    Get PDF
    We are developing kilo-pixel arrays of transition-edge sensor (TES) microcalorimeters for future X-ray astronomy observatories or for use in laboratory astrophysics applications. For example, Athena/XMS (currently under study by the european space agency) would require a close-packed 32x32 pixel array on a 250-micron pitch with < 3.0 eV full-width-half-maximum energy resolution at 6 keV and at count-rates of up to 50 counts/pixel/second. We present characterization of 32x32 arrays. These detectors will be readout using state of the art SQUID based time-domain multiplexing (TDM). We will also present the latest results in integrating these detectors and the TDM readout technology into a 16 row x N column field-able instrument
    • …
    corecore