171 research outputs found

    The fundamental pro-groupoid of an affine 2-scheme

    Full text link
    A natural question in the theory of Tannakian categories is: What if you don't remember \Forget? Working over an arbitrary commutative ring RR, we prove that an answer to this question is given by the functor represented by the \'etale fundamental groupoid \pi_1(\spec(R)), i.e.\ the separable absolute Galois group of RR when it is a field. This gives a new definition for \'etale \pi_1(\spec(R)) in terms of the category of RR-modules rather than the category of \'etale covers. More generally, we introduce a new notion of "commutative 2-ring" that includes both Grothendieck topoi and symmetric monoidal categories of modules, and define a notion of π1\pi_1 for the corresponding "affine 2-schemes." These results help to simplify and clarify some of the peculiarities of the \'etale fundamental group. For example, \'etale fundamental groups are not "true" groups but only profinite groups, and one cannot hope to recover more: the "Tannakian" functor represented by the \'etale fundamental group of a scheme preserves finite products but not all products.Comment: 46 pages + bibliography. Diagrams drawn in Tik

    Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

    Get PDF
    Like MMCs, MPTs enable high energy microcalorimeters with zero bias power dissipation and potential resolution < 1 eV. MPTs can provide d(phi)/dT as large as 1000 (Phi)(sub 0)/K, with no excess noise, thereby reducing the importance of SQUID noise. Long coherence length in a Type-I superconducting MoAu film offers multiple advantages for efficient flux expulsion in MPT. Region of steepest d(phi)/dT is the Meissner effect in the small device; flux is expelled/penetrates to minimize free energy. Steepness of transition can be engineered with choice of film thickness and coil pitch relative to lambda(sub eff)(0), ratio of T/T(sub c), and bias circuit inductance

    Simvastatin improves the sexual health-related quality of life in men aged 40 years and over with erectile dysfunction : Additional data from the Erectile Dysfunction and Statin trial

    Get PDF
    © 2014 Trivedi et al. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.Background: Erectile dysfunction is prevalent in men over 40 years, affecting their quality of life and that of their partners. The aims of this study were:a)To evaluate the internal reliability of the male erectile dysfunction specific quality of life (MED-QoL) scale and explore its factor structure.b)To evaluate the effect of simvastatin on subscales of the MED-QoL in men over forty years with erectile dysfunction. Methods: This is a double blind randomised controlled trial of 40 mg simvastatin or placebo given once daily for six months to men over forty years with untreated erectile dysfunction, who were not at high cardiovascular risk and were not on anti-hypertensive or lipid-lowering medication. 173 eligible men were recruited from 10 general practices in East of England. Data were collected at two points over 30 weeks. We report on the factor structure of MED-QoL, the internal reliability of the scale and the derived subscales, and the effect of simvastatin on MED-QoL subscales. Results: An initial analysis of the MED-QoL items suggested that a number of items should be removed (MED-QoL-R). Exploratory factor analysis identified three subscales within the MED-QoL-R which accounted for 96% of the variance, related to feelings of Control, initiating Intimacy, and Emotional response to erectile dysfunction. The alpha value for the revised scale (MED-Qol-R) was >0.95 and exceeded .82 for each subscale. Regression analysis showed that patients in the placebo group experienced a significantly reduced feeling of Control over erectile dysfunction than those in the statin group. Those in the placebo group had significantly lower Emotional response than those in the statin group at the close of trial, but there was no significant treatment effect on Intimacy. Conclusions: Our revised MED-QoL-R identified three subscales. Secondary analysis showed a significant improvement in sexual health related quality of life, specifically in relation to perception of control and emotional health in men with untreated erectile dysfunction given 40 mg simvastatin for six months. Trial registration: Current Controlled Trials ISRCTN66772971.Peer reviewe

    Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

    Get PDF
    Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution

    Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163^{163}Ho ions

    Full text link
    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163^{163}Ho using MMCs having the radioactive 163^{163}Ho ions implanted in the absorber. The implantation of 163^{163}Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. In addition an optimized detector design for future 163^{163}Ho experiments is presented

    Development of Kilo-Pixel Arrays of Transition-Edge Sensors for X-Ray Spectroscopy

    Get PDF
    We are developing kilo-pixel arrays of transition-edge sensor (TES) microcalorimeters for future X-ray astronomy observatories or for use in laboratory astrophysics applications. For example, Athena/XMS (currently under study by the european space agency) would require a close-packed 32x32 pixel array on a 250-micron pitch with < 3.0 eV full-width-half-maximum energy resolution at 6 keV and at count-rates of up to 50 counts/pixel/second. We present characterization of 32x32 arrays. These detectors will be readout using state of the art SQUID based time-domain multiplexing (TDM). We will also present the latest results in integrating these detectors and the TDM readout technology into a 16 row x N column field-able instrument

    Magnetic Penetration Effects in Small Superconducting Devices

    Get PDF
    The temperature dependent behavior of a superconducting body in an applied magnetic field involves flux penetration/expulsion both from screening currents (within a magnetic penetration depth) and variations in the superconducting order parameter (locally to form vortices or a mixed state, or globally in the Meissner effect). The temperature dependence of the magnetic penetration depth, in particular, has been used to make highly sensitive macroscopic thermometers. For the microscopic device volumes required in sensitive low temperature photon detectors, properties of actual thin film materials, non-uniformity of applied magnetic fields, and the influence of measurement circuit dynamics are complicating factors. We discuss the various penetration effects as demonstrated in a particularly promising combination of material and geometry that we have used to make sensitive x-ray microcalorimeters

    Voluntary stopping of eating and drinking in Switzerland from different points of view : protocol for a mixed-methods study

    Get PDF
    “To die with dignity” has reached the significance of a core value in democratic societies. Based on this unconditional value, people require autonomy and care. "Voluntary stopping of eating and drinking" (VSED) represents an alternative to assisted suicide because no one else is involved in the action of death fastening, even though from outside, it might be considered as an extreme form of passive euthanasia. However, there are no data available about the prevalence and frequency of either explicit VSED or the implicit reduction of food and liquid in Switzerland. The responsible and independent ethics committee of the Greater Region of Eastern Switzerland (EKOS 17/083) approved this study

    Performance and Characterization of Magnetic Penetration Thermometer Devices for X-Ray Spectroscopy

    Get PDF
    We are developing magnetic penetration thermometers (MPTs) for applications in X-ray astronomy. These non-dissipative devices consist of an X-ray absorber in good thermal contact to a superconducting thin film with a transition temperature around T=100mK. A microfabricated superconducting planar inductor underneath is used to store a persistent current and couple the superconductor's diamagnetic response to a readout SQUID. The strong temperature dependence of the diamagnetic response make these devices suitable for highly sensitive macroscopic thermometers that are capable of achieving very high energy resolution. We present results achieved with MPTs consisting of MoAu bilayer sensors attached to overhanging square 250 micron by 250 micron gold absorbers that have demonstrated an energy resolution of delta E_FWHM=2.3eV at an X-ray energy of 5.9keV. A similar device has shown delta E_FWHM=2.0eV at 1.5 keV. Under certain conditions and for specific device geometries, the temperature responsivity of the MPTs can vary on long timescales degrading the spectral performance. We present the characterization of different inductor geometries to optimize the design for the highest possible temperature sensitivity and compare different device designs with respect to responsivity stability

    Non-response in a survey of physicians on end-of-life care for the elderly

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Physicians are quite often surveyed with the aim to investigate their opinions regarding provision and improvement of health care. However, in many cases response rates tend to be rather low. The aim of the study is to reflect methodological aspects regarding survey conduction and to analyse factors that cause physicians to take part in a study on delivering end-of-life care for the elderly.</p> <p>Methods</p> <p>N = 4,727 physicians in Lower Saxony, Germany, received a standardised questionnaire on their attitudes about end-of-life care for the elderly. Non-responders were asked to state the reasons for non-participation. Comparison of the sociodemographic characteristics between responders and non-responders, and evaluation of the reasons for non-participation were made.</p> <p>Results</p> <p>The response rate to the questionnaire on end-of-life care for the elderly was 40% (n = 1,892). Of the non-responders to the questionnaire, 12.8% (n = 364) stated the reasons for non-participation. Overall, the response rate to the questionnaire varied with specialty and location of the practice: radiotherapists answered significantly more frequently than other categories of physician (e.g. general practitioners) and physicians in rural areas significantly more frequently than their colleagues in urban areas. The reasons most frequently given for non-participation were "Not concerned with the subject" and "No time".</p> <p>Conclusions</p> <p>The varying rates of response indicate that the survey was not sufficiently relevant to all groups of physicians, or that the awareness of the topic may be partly underdeveloped.</p
    corecore