33 research outputs found

    Development and validation of a method for determination of Eculizumab concentration in human plasma by biolayer interferometry

    No full text
    The article describes a new method for measurement of monoclonal antibody Eculizumab concentration in human plasma in a range of 3-250 ΞΌg/ml. In this method we used an antibody Fab fragment, capable of binding to eculizumab specifically in human plasma. The method uses the biolayer interferometry for determination of Eculizumab concentration without additional tag in the analyzing substances. This method was comparatively validated along with the traditional ELISA. Comparative validation demonstrated that the biolayer interferometry based method has an advantage to the ELISA in such important statistical criteria as an analytical range, accuracy, precision, specificity and selectivity (matrix effect)

    Spectroscopy of superheavy hydrogen isotopes

    No full text
    The superheavy hydrogen isotopes 4H and 5H have been investigated in the stopped pion absorption on 9Be. Three states of 4H were proposed in the reaction channel 9Be( Ο€{ - }, dt)X. Four states of 5H were proposed in the reaction channels 9Be(Ο€{ - }, pt)X and 9Be(Ο€{ - }, dt)X. The excited states of 5H can decay into free nucleons

    Search for superheavy hydrogen isotopes

    No full text
    Experimental search for superheavy hydrogen isotopes 6H and 7H was performed in the stopped pion absorption on 9Be and 11B nuclei. The structures in the missing-mass spectra were observed in the reaction channels 9Be(Ο€-, pd )X and 11B(Ο€-, p4He)X . Four states of 6H were proposed. Evidences for 7H formation were obtained in the reaction channels 9Be(Ο€-, pp)X and 11B(Ο€-, p3He)X

    Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΈ валидация ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ опрСдСлСния ΠΊΠΎΠ½Ρ†Π΅Π½Ρ‚Ρ€Π°Ρ†ΠΈΠΈ экулизумаба Π² ΠΏΠ»Π°Π·ΠΌΠ΅ ΠΊΡ€ΠΎΠ²ΠΈ Ρ‡Π΅Π»ΠΎΠ²Π΅ΠΊΠ° с ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ΠΌ Ρ‚Π΅Ρ…Π½ΠΎΠ»ΠΎΠ³ΠΈΠΈ биослойной ΠΈΠ½Ρ‚Π΅Ρ€Ρ„Π΅Ρ€ΠΎΠΌΠ΅Ρ‚Ρ€ΠΈΠΈ

    No full text
    The article describes a new method for measurement of monoclonal antibody Eculizumab concentration in human plasma in a range of 3-250 ΞΌg/ml. In this method we used an antibody Fab fragment, capable of binding to eculizumab specifically in human plasma. The method uses the biolayer interferometry for determination of Eculizumab concentration without additional tag in the analyzing substances. This method was comparatively validated along with the traditional ELISA. Comparative validation demonstrated that the biolayer interferometry based method has an advantage to the ELISA in such important statistical criteria as an analytical range, accuracy, precision, specificity and selectivity (matrix effect).Π Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π° ΠΈ Π²Π°Π»ΠΈΠ΄ΠΈΡ€ΠΎΠ²Π°Π½Π° ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° опрСдСлСния ΠΊΠΎΠ½Ρ†Π΅Π½Ρ‚Ρ€Π°Ρ†ΠΈΠΈ ΠΏΡ€Π΅ΠΏΠ°Ρ€Π°Ρ‚Π° моноклонального тСрапСвтичСского Π°Π½Ρ‚ΠΈΡ‚Π΅Π»Π° экулизумаб Π² ΠΏΠ»Π°Π·ΠΌΠ΅ ΠΊΡ€ΠΎΠ²ΠΈ Ρ‡Π΅Π»ΠΎΠ²Π΅ΠΊΠ° Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ ΠΊΠΎΠ½Ρ†Π΅Π½Ρ‚Ρ€Π°Ρ†ΠΈΠΉ 3-250 ΠΌΠΊΠ³/ΠΌΠ». ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° основана Π½Π° взаимодСйствии ΠΈΠΌΠΌΠΎΠ±ΠΈΠ»ΠΈΠ·ΠΎΠ²Π°Π½Π½ΠΎΠ³ΠΎ Fab-Ρ„Ρ€Π°Π³ΠΌΠ΅Π½Ρ‚Π° Π°Π½Ρ‚ΠΈΡ‚Π΅Π»Π°, спСцифичного ΠΊ экулизумабу Π² ΠΎΠ±Ρ€Π°Π·Ρ†Π΅ ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΊΡ€ΠΎΠ²ΠΈ. ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅Ρ‚ ΠΏΡ€ΠΈΠ½Ρ†ΠΈΠΏ биослойной ΠΈΠ½Ρ‚Π΅Ρ€Ρ„Π΅Ρ€ΠΎΠΌΠ΅Ρ‚Ρ€ΠΈΠΈ, ΠΏΠΎΠ·Π²ΠΎΠ»ΡΡŽΡ‰ΠΈΠΉ Π±Π΅Π· внСсСния Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΌΠ΅Ρ‚ΠΎΠΊ ΠΎΡ†Π΅Π½ΠΈΡ‚ΡŒ ΠΊΠΎΠ½Ρ†Π΅Π½Ρ‚Ρ€Π°Ρ†ΠΈΡŽ Π°Π½Π°Π»ΠΈΠ·ΠΈΡ€ΡƒΠ΅ΠΌΠΎΠ³ΠΎ вСщСства. Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ Π²Π°Π»ΠΈΠ΄Π°Ρ†ΠΈΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ ΡΠΎΠΏΠΎΡΡ‚Π°Π²Π»ΡΠ»ΠΈΡΡŒ с Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°ΠΌΠΈ Π²Π°Π»ΠΈΠ΄Π°Ρ†ΠΈΠΈ Π°Π»ΡŒΡ‚Π΅Ρ€Π½Π°Ρ‚ΠΈΠ²Π½ΠΎΠΉ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ Π½Π° основС ΠΈΠΌΠΌΡƒΠ½ΠΎΡ„Π΅Ρ€ΠΌΠ΅Π½Ρ‚Π½ΠΎΠ³ΠΎ Π°Π½Π°Π»ΠΈΠ·Π°. По ΠΈΡ‚ΠΎΠ³Π°ΠΌ исслСдования ΠΏΠΎΠΊΠ°Π·Π°Π½ΠΎ прСимущСство ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ Π½Π° основС биослойной ΠΈΠ½Ρ‚Π΅Ρ€Ρ„Π΅Ρ€ΠΎΠΌΠ΅Ρ‚Ρ€ΠΈΠΈ ΠΏΠΎ основным мСтрологичСским характСристикам - аналитичСскому Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Ρƒ, ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½ΠΎΡΡ‚ΠΈ, прСцизионности ΠΈ сСлСктивности
    corecore