303 research outputs found

    Surface passivation effect by fluorine plasma treatment on ZnO for efficiency and lifetime improvement of inverted polymer solar cells

    Get PDF
    Zinc oxide (ZnO) is an important material for polymer solar cells (PSCs) where the characteristics of the interface can dominate both the efficiency and lifetime of the device. In this work we study the effect of fluorine (SF6) plasma surface treatment of ZnO films on the performance of PSCs with an inverted structure. The interaction between fluorine species present in the SF6 plasma and the ZnO surface is also investigated in detail. We provide fundamental insights into the passivation effect of fluorine by analyzing our experimental results and theoretical calculations and we propose a mechanism according to which a fluorine atom substitutes an oxygen atom or occupies an oxygen vacancy site eliminating an electron trap while it may also attract hydrogen atoms thus favoring hydrogen doping. These multiple fluorine roles can reduce both the recombination losses and the electron extraction barrier at the ZnO/fullerene interface improving the selectivity of the cathode contact. Therefore, the fabricated devices using the fluorine plasma treated ZnO show high efficiency and stable characteristics, irrespective of the donor : acceptor combinations in the photoactive blend. Inverted polymer solar cells, consisting of the P3HT:PC71BM blend, exhibited increased lifetime and high power conversion efficiency (PCE) of 4.6%, while the ones with the PCDTBT:PC71BM blend exhibited a PCE of 6.9%. Our champion devices with the PTB7:PC71BM blends reached a high PCE of 8.0% and simultaneously showed exceptional environmental stability when using the fluorine passivated ZnO cathode interlayers

    Successful Treatment of Postoperative External Biliary Fistula by Selective Nasobiliary Drainage

    Get PDF
    A 25-year old man presented with a high output external biliary fistula after an operation for a giant hydatid cyst of the liver. Endoscopic sphincterotomy was inadequate to close the fistula. A nasobiliary tube was selectively inserted into the leaking hepatic duct and bile was continuously aspirated. The fistula and the residual cavity healed completely. Details of the patients' management using this alternative technique, are discussed

    Development of a Nanodroplet Formulation for Triggered Release of BIO for Bone Fracture Healing

    Get PDF
    Impaired fracture healing impacts patients’ quality of life and imposes a financial burden on healthcare services. Up to 10% of bone fractures result in delayed/non-union fractures, for which new treatments are urgently required. However, systemic delivery of bone anabolic molecules is often sub-optimal and can lead to significant side effects. In this study, we developed ultrasound (US) responsive nano-sized vehicles in the form of perfluorocarbon nanodroplets (NDs), as a means of targeting delivery of drugs to localised tissues. We tested the hypothesis that NDs could stably encapsulate BIO (GSK-3β inhibitor), which could then be released upon US stimulation to activate Wnt signalling and induce ossification. NDs (~280 nm) were prepared from phospholipids and liquid perfluorocarbon and their stability and drug loading was studied by NTA (Nano Tracking Analysis) and HPLC. ND cytotoxicity was assessed in patient-derived bone marrow stromal cells (BMSCs) with Alamar Blue (24 h), and in vitro bioactivity of BIO-NDs was evaluated in a 3T3 Wnt-pathway reporter cell line with luciferase readout. To investigate the acoustic behaviour of NDs, 2% agarose (LM) containing NDs was injected into a bespoke bone fracture model (Sawbones) of various geometries and stimulated by US (1 MHz, 5% duty cycle, 1 MPa, 30 s), allowing the simultaneous capture of optical images and acoustic emissions. Femoral bone hole defects (1–2 mm) were made in WT-MF1 mice (age: 8–12 wks) and DiR-labelled NDs (100 µL, 109 NDs/mL, i.v.) were injected post-fracture to determine biodistribution by IVIS imaging. NDs were stable (4 and 37 °C) and retained >90% BIO until US was applied, which caused ~100% release. ND exposure up to a concentration of 109 NDs/mL showed no cytotoxicity (24 h). BIO-loaded NDs induced Wnt pathway activation in a dose dependent manner. Biodistribution of DiR-NDs in a femoral bone hole defect model in mice demonstrated increased localisation at the fracture site (~2-fold relative to that found in healthy mice or contralateral femurs at 48 h)

    Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions

    Get PDF
    Liquid perfluorocarbon nanodroplets (NDs) are an attractive alternative to microbubbles (MBs) for ultrasound-mediated therapeutic and diagnostic applications. ND size and size distribution have a strong influence on their behaviour in vivo, including extravasation efficiency, circulation time, and response upon ultrasound stimulation. Thus, it is desirable to identify ways to tailor the ND size and size distribution during manufacturing. In this study phospholipid-coated NDs, comprising a perfluoro-n-pentane (PFP) core stabilised by a DSPC/PEG40s (1,2-distearoyl-sn-glycero-3-phosphocholine and polyoxyethylene(40)stearate, 9:1 molar ratio) shell, were produced in phosphate-buffered saline (PBS) by sonication. The effect of the following production-related parameters on ND size was investigated: PFP concentration, power and duration of sonication, and incorporation of a lipophilic fluorescent dye. ND stability was also assessed at both 4°C and 37°C. When a sonication pulse of 6 s and 15% duty cycle was employed, increasing the volumetric concentration of PFP from 5% to 15% v/v in PBS resulted in an increase in ND diameter from 215.8 ± 16.8 nm to 408.9 ± 171.2 nm. An increase in the intensity of sonication from 48 to 72 W (with 10% PFP v/v in PBS) led to a decrease in ND size from 354.6 ± 127.2 nm to 315.0 ± 100.5 nm. Increasing the sonication time from 20 s to 40 s (using a pulsed sonication with 30% duty cycle) did not result in a significant change in ND size (in the range 278 - 314 nm); however, when it was increased to 60 s, the average ND diameter reduced to 249.7 ± 9.7 nm, which also presented a significantly lower standard deviation compared to the other experimental conditions investigated (i.e., 9.7 nm vs. > 49.4 nm). The addition of the fluorescent dye DiI at different molar ratios did not affect the ND size distribution. NDs were stable at 4°C for up to 6 days and at 37°C for up to 110 min; however, some evidence of ND-to-MB phase transition was observed after 40 min at 37°C. Finally, phase transition of NDs into MBs was demonstrated using a tissue-mimicking flow phantom under therapeutic ultrasound exposure conditions (ultrasound frequency: 0.5 MHz, acoustic pressure: 2-4 MPa, and pulse repetition frequency: 100 Hz)

    Effects of different concentrations of carbamide peroxide and bleaching periods on the roughness of dental ceramics

    Full text link
    The wide use of dental bleaching treatment has brought concern about the possible effects of hydrogen peroxide on dental tissue and restorative materials. The objective of this study was to evaluate in vitro the effect of nightguard bleaching on the surface roughness of dental ceramics after different periods of bleaching treatment. Fifteen specimens of 5 × 3 × 1 mm were created with three dental ceramics following the manufacturers' instructions: IPS Classic (Ivoclar-Vivadent); IPS d.Sign (Ivoclar-Vivadent); and VMK-95 (Vita). A profilometer was used to evaluate baseline surface roughness (Ra values) of all ceramics by five parallel measurements with five 0.25 mm cut off (Λc) at 0.1 mm/s. Afterwards, all specimens were submitted to 6-h daily bleaching treatments with 10% or 16% carbamide peroxide (Whiteness- FGM) for 21 days, while control groups from each ceramic system were stored in artificial saliva. The surface roughness of all groups was evaluated after 18 h, 42 h, 84 h, and 126 h of bleaching treatment. The surface roughness of each specimen (n = 5) was based on the mean value of five parallel measurements in each time and all data were submitted to two-way repeated measures ANOVA and Tukey's post-hoc test (α = 0.05). No significant differences in ceramic surface roughness were observed between untreated and bleached ceramic surfaces, regardless of bleaching intervals or bleaching treatments. This study provided evidence that at-home bleaching systems do not cause detrimental effects on surface roughness of dental ceramics

    Bisphenol A-glycidyl methacrylate induces a broad spectrum of DNA damage in human lymphocytes

    Get PDF
    Bisphenol A-glycidyl methacrylate (BisGMA) is monomer of dental filling composites, which can be released from these materials and cause adverse biologic effects in human cells. In the present work, we investigated genotoxic effect of BisGMA on human lymphocytes and human acute lymphoblastic leukemia cell line (CCRF-CEM) cells. Our results indicate that BisGMA is genotoxic for human lymphocytes. The compound induced DNA damage evaluated by the alkaline, neutral, and pH 12.1 version of the comet assay. This damage included oxidative modifications of the DNA bases, as checked by DNA repair enzymes EndoIII and Fpg, alkali-labile sites and DNA double-strand breaks. BisGMA induced DNA-strand breaks in the isolated plasmid. Lymphocytes incubated with BisGMA at 1 mM were able to remove about 50% of DNA damage during 120-min repair incubation. The monomer at 1 mM evoked a delay of the cell cycle in the S phase in CCRF-CEM cells. The experiment with spin trap—DMPO demonstrated that BisGMA induced reactive oxygen species, which were able to damage DNA. BisGMA is able to induce a broad spectrum of DNA damage including severe DNA double-strand breaks, which can be responsible for a delay of the cell cycle in the S phase

    Expanding the Grading of Recommendations Assessment, Development, and Evaluation (Ex-GRADE) for Evidence-Based Clinical Recommendations: Validation Study

    Get PDF
    Clinicians use general practice guidelines as a source of support for their intervention, but how much confidence should they place on these recommendations? How much confidence should patients place on these recommendations? Various instruments are available to assess the quality of evidence of research, such as the revised Wong scale (R-Wong) which examines the quality of research design, methodology and data analysis, and the revision of the assessment of multiple systematic reviews (R-AMSTAR), which examines the quality of systematic reviews
    corecore