    Rehabilitation of the Paralyzed Lower Limbs Using Functional Electrical Stimulation: Robust Closed Loop Control

    Get PDF
    International audienceFunctional electrical stimulation (FES) is used to excite paralyzed muscles that would otherwise be uncontrollable by paraplegic patients. Consequently, the patient could recover partially some of its lower limb functions improving thus the cardiovascular system, increasing oxygen uptake and bettering the whole quality of life. The main challenge that we face when applying FES to the paralyzed lower limbs is to avoid hyperstimulation and to defer the muscular fatigue as much as possible. One of our goals is to compute the needed patterns stimulation (current and/or pulse width) necessary to perform a desired given motion of the knee joint. This later is actuated by two groups of antagonist muscles: quadriceps and hamstrings causing respectively extension and flexion of the knee. The muscle model used in this study is based on a physio-mathematical formulation of the macroscopic Hill and microscopic Huxley concepts. Parameters of the biomechanical model (muscles-knee) were identified based on experimental measures. Afterward, we apply two robust nonlinear control strategies: the High Order Sliding Mode (HOSM) controller and the Model Predictive Controller (MPC) also known as receding horizon controller. These controllers have been evaluated in simulation to hightlight i) their performance in terms of capability of tracking a pre-defined reference trajectory and ii) the robustness against force perturbation and model mismatch. The performances of these controllers have also been compared with a classical pole placement controller

    Theme F "medical robotics for training and guidance": Results and future work

    Get PDF
    International audienceThis paper presents the projects of the Theme F "medical robotics for training and guidance" inside the GdR STIC-Santé. Three scientific meeting days have been organized during the period 2011-2012. They were devoted to physical simulators of behavior for gesture learning, command of hand prostheses by myoelectric signals or brain activity and the manipulation of objects by the artificial hand, and the last to the use of robots for medical gestures. The next event, scheduled for early 2013, will focus on the evaluation of gesture and especially "evaluation of gesture - to do what?"

    SICOMAT : a system for SImulation and COntrol analysis of MAchine Tools

    Get PDF
    International audienceThis paper presents a software package for the simulation and the control analysis of machine tool axes. This package which is called SICOMAT (SImulation and COntrol analysis of MAchine Tools), provides a large variety of toolboxes to analyze the behavior and the control of the machine. The software takes into account several elements such as the exibility of bodies, the interaction between several axes, the effect of numerical control and the availability to reduce models

    SICOMAT : a system for SImulation and COntrol analysis of MAchine Tools

    Get PDF
    International audienceThis paper presents a software package for the simulation and the control analysis of machine tool axes. This package which is called SICOMAT (SImulation and COntrol analysis of MAchine Tools), provides a large variety of toolboxes to analyze the behavior and the control of the machine. The software takes into account several elements such as the flexibility of bodies, the interaction between several axes, the effect of numerical control and the availability to reduce models

    In Vivo

    Get PDF
    International audienceSkeletal muscle system has nonlinear dynamics and subject-specific characteristics. Thus, it is essential to identify unknown parameters from noisy biomedical signals to improve the modeling accuracy in neuroprosthetic control. The objective of this work is to develop an experimental identification method for subject-specific biomechanical parameters of a physiological muscle model which can be employed to predict the nonlinear force properties of stimulated muscle. Our previously proposed muscle model, which can describe multi-scale physiological system based on the Hill and Huxley models, was used for the identification. The identification protocols were performed on two rabbit experiments, where the medial gastrocnemius was attached to a motorized lever system to record the force by the nerve stimulation. The muscle model was identified using nonlinear Kalman filters: Sigma-Point and Extended Kalman Filter. The identified model was evaluated by comparison with experimental measurements in cross-validation manner. The feasibility could be demonstrated by comparison between the estimated parameter and the measured value. The estimates with SPKF showed 5.7% and 2.9% error in each experiment with 7 different initial conditions. It reveals that SPKF has great advantage especially for the identification of multi-scale muscle model which accounts for the high nonlinearity and discontinuous states between muscle contraction and relaxation process

    Unsupervised Trajectory Segmentation for Surgical Gesture Recognition in Robotic Training

    No full text
    International audienceDexterity and procedural knowledge are two critical skills that surgeons need to master to perform accurate and safe surgical interventions. However, current training systems do not allow us to provide an in-depth analysis of surgical gestures to precisely assess these skills. Our objective is to develop a method for the automatic and quantitative assessment of surgical gestures. To reach this goal, we propose a new unsupervised algorithm that can automatically segment kinematic data from robotic training sessions. Without relying on any prior information or model, this algorithm detects critical points in the kinematic data that define relevant spatio-temporal segments. Based on the association of these segments, we obtain an accurate recognition of the gestures involved in the surgical training task. We, then, perform an advanced analysis and assess our algorithm using datasets recorded during real expert training sessions. After comparing our approach with the manual annotations of the surgical gestures, we observe 97.4% accuracy for the learning purpose and an average matching score of 81.9% for the fully automated gesture recognition process. Our results show that trainees workflow can be followed and surgical gestures may be automatically evaluated according to an expert database. This approach tends toward improving training efficiency by minimizing the learning curve

    Synthesis of optimal electrical stimulation patterns for functional motion restoration: applied to spinal cord-injured patients

    Get PDF
    We investigated the synthesis of electrical stimulation patterns for functional movement restoration in human paralyzed limbs. We considered the knee joint system, co-activated by the stimulated quadriceps and hamstring muscles. This synthesis is based on optimized functional electrical stimulation (FES) patterns to minimize muscular energy consumption and movement efficiency criteria. This two-part work includes a multi-scale physiological muscle model, based on Huxley’s formulation. In the simulation, three synthesis strategies were investigated and compared in terms of muscular energy consumption and co-contraction levels. In the experimental validation, the synthesized FES patterns were carried out on the quadriceps-knee joint system of four complete spinal cord injured subjects. Surface stimulation was applied to all subjects, except for one FES-implanted subject who received neural stimulation. In each experimental validation, the model was adapted to the subject through a parameter identification procedure. Simulation results were successful and showed high co-contraction levels when reference trajectories were tracked. Experimental validation results were encouraging, as the desired and measured trajectories showed good agreement, with an 8.4 % rms error in a subject without substantial time-varying behavior. We updated the maximal isometric force in the model to account for time-varying behavior, which improved the average rms errors from 31.4 to 13.9 % for all subjects

    AIR2, un robot parallèle à actionnement pneumatique à deux degrés de liberté pour les applications de prise et dépose d'objets

    Get PDF
    Un prototype de robot parallèle actionné pneumatiquement à deux degrés de liberté a été développé afin de rendre accessible aux petites et moyennes entreprises la robotisation de tâches qui nécessiteraient le déplacement de charges de 5 à 25 kg en utilisant des vérins standards moins onéreux que les moteurs électriques. Après une présentation de la structure mécanique du robot ainsi que ses modèles, la stratégie de commande innovante (commande prédictive avec boucle interne de force H-infini) est brièvement introduite, puis les résultats obtenus expérimentalement sont présentés et analysés
    • …