22 research outputs found

    An ARPES view on the high-Tc problem: phonons vs spin-fluctuations

    Full text link
    We review the search for a mediator of high-Tc superconductivity focusing on ARPES experiment. In case of HTSC cuprates, we summarize and discuss a consistent view of electronic interactions that provides natural explanation of both the origin of the pseudogap state and the mechanism for high temperature superconductivity. Within this scenario, the spin-fluctuations play a decisive role in formation of the fermionic excitation spectrum in the normal state and are sufficient to explain the high transition temperatures to the superconducting state while the pseudogap phenomenon is a consequence of a Peierls-type intrinsic instability of electronic system to formation of an incommensurate density wave. On the other hand, a similar analysis being applied to the iron pnictides reveals especially strong electron-phonon coupling that suggests important role of phonons for high-Tc superconductivity in pnictides.Comment: A summary of the ARPES part of the Research Unit FOR538, http://for538.wmi.badw.d

    Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing Crohn's disease patients: the METRIC diagnostic accuracy study

    Get PDF
    Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. Prospective multicentre cohort study. Eight NHS hospitals. Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. Magnetic resonance enterography and ultrasonography. The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%;  = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. Current Controlled Trials ISRCTN03982913. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in ; Vol. 23, No. 42. See the NIHR Journals Library website for further project information

    Bio-analytical Assay Methods used in Therapeutic Drug Monitoring of Antiretroviral Drugs-A Review

    Get PDF

    5-Lipoxygenase Metabolic Contributions to NSAID-Induced Organ Toxicity

    Full text link

    Efficient digital sweep oscillator with extremely low sweep rates

    No full text

    Detection of extracolonic pathologic findings with CT colonography: a discrete choice experiment of perceived benefits versus harms

    Get PDF
    PurposeTo determine the maximum rate of false-positive diagnoses that patients and health care professionals were willing to accept in exchange for detection of extracolonic malignancy by using computed tomographic (CT) colonography for colorectal cancer screening.Materials and MethodsAfter obtaining ethical approval and informed consent, 52 patients and 50 health care professionals undertook two discrete choice experiments where they chose between unrestricted CT colonography that examined intra- and extracolonic organs or CT colonography restricted to the colon, across different scenarios. The first experiment detected one extracolonic malignancy per 600 cases with a false-positive rate varying across scenarios from 0% to 99.8%. One experiment examined radiologic follow-up generated by false-positive diagnoses while the other examined invasive follow-up. Intracolonic performance was identical for both tests. The median tipping point (maximum acceptable false-positive rate for extracolonic findings) was calculated overall and for both groups by bootstrap analysis.ResultsThe median tipping point for radiologic follow-up occurred at a false-positive rate greater than 99.8% (interquartile ratio [IQR], 10 to >99.8%). Participants would tolerate at least a 99.8% rate of unnecessary radiologic tests to detect an additional extracolonic malignancy. The median tipping-point for invasive follow-up occurred at a false-positive rate of 10% (IQR, 2 to >99.8%). Tipping points were significantly higher for patients than for health care professionals for both experiments (>99.8 vs 40% for radiologic follow-up and >99.8 vs 5% for invasive follow-up, both P < .001).ConclusionPatients and health care professionals are willing to tolerate high rates of false-positive diagnoses with CT colonography in exchange for diagnosis of extracolonic malignancy. The actual specificity of screening CT colonography for extracolonic findings in clinical practice is likely to be highly acceptable to both patients and health care professionals
    corecore