76 research outputs found

    Vibration Response Imaging: evaluation of rater agreement in healthy subjects and subjects with pneumonia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We evaluated pulmonologists variability in the interpretation of Vibration response imaging (VRI) obtained from healthy subjects and patients hospitalized for community acquired pneumonia.</p> <p>Methods</p> <p>The present is a prospective study conducted in a tertiary university hospital. Twenty healthy subjects and twenty three pneumonia cases were included in this study. Six pulmonologists blindly analyzed images of normal subjects and pneumonia cases and evaluated different aspects of VRI images related to the quality of data aquisition, synchronization of the progression of breath sound distribution and agreement between the maximal energy frame (MEF) of VRI (which is the maximal geographical area of lung vibrations produced at maximal inspiration) and chest radiography. For qualitative assessment of VRI images, the raters' evaluations were analyzed by degree of consistency and agreement.</p> <p>Results</p> <p>The average value for overall identical evaluations of twelve features of the VRI image evaluation, ranged from 87% to 95% per rater (94% to 97% in control cases and from 79% to 93% per rater in pneumonia cases). Inter-rater median (IQR) agreement was 91% (82-96). The level of agreement according to VRI feature evaluated was in most cases over 80%; intra-class correlation (ICC) obtained by using a model of subject/rater for the averaged features was overall 0.86 (0.92 in normal and 0.73 in pneumonia cases).</p> <p>Conclusions</p> <p>Our findings suggest good agreement in the interpretation of VRI data between different raters. In this respect, VRI might be helpful as a radiation free diagnostic tool for the management of pneumonia.</p

    Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition

    Get PDF
    BACKGROUND: The RTOG 94-13 trial has provided evidence that patients with high risk prostate cancer benefit from an additional radiotherapy to the pelvic nodes combined with concomitant hormonal ablation. Since lymphatic drainage of the prostate is highly variable, the optimal target volume definition for the pelvic lymph nodes is problematic. To overcome this limitation, we tested the feasibility of an intensity modulated radiation therapy (IMRT) protocol, taking under consideration the individual pelvic sentinel node drainage pattern by SPECT functional imaging. METHODS: Patients with high risk prostate cancer were included. Sentinel nodes (SN) were localised 1.5–3 hours after injection of 250 MBq (99m)Tc-Nanocoll using a double-headed gamma camera with an integrated X-Ray device. All sentinel node localisations were included into the pelvic clinical target volume (CTV). Dose prescriptions were 50.4 Gy (5 × 1.8 Gy / week) to the pelvis and 70.0 Gy (5 × 2.0 Gy / week) to the prostate including the base of seminal vesicles or whole seminal vesicles. Patients were treated with IMRT. Furthermore a theoretical comparison between IMRT and a three-dimensional conformal technique was performed. RESULTS: Since 08/2003 6 patients were treated with this protocol. All patients had detectable sentinel lymph nodes (total 29). 4 of 6 patients showed sentinel node localisations (total 10), that would not have been treated adequately with CT-based planning ('geographical miss') only. The most common localisation for a probable geographical miss was the perirectal area. The comparison between dose-volume-histograms of IMRT- and conventional CT-planning demonstrated clear superiority of IMRT when all sentinel lymph nodes were included. IMRT allowed a significantly better sparing of normal tissue and reduced volumes of small bowel, large bowel and rectum irradiated with critical doses. No gastrointestinal or genitourinary acute toxicity Grade 3 or 4 (RTOG) occurred. CONCLUSION: IMRT based on sentinel lymph node identification is feasible and reduces the probability of a geographical miss. Furthermore, IMRT allows a pronounced sparing of normal tissue irradiation. Thus, the chosen approach will help to increase the curative potential of radiotherapy in high risk prostate cancer patients

    Poor Breath Sounds with Good Voice Sounds

    No full text

    Reduction of Heart Sounds from Lung Sounds by Adaptive Filterng

    No full text

    A simple Method to Monitor Performance of Forced Vital Capacity

    No full text
    APPLICATION OF PULSES OF NEGATIVE PRESSURE PROVIDES A SIMPLE METHOD FOR ON-LINE RECOGNITION OF WHETHER AN FVC MANEUVERS IS PERFORMED WITH SUFFICIENT EFFORT TO ACHIEVE FLOW LIMITATIO

    Flow limitation and dyspnea in normal supine subjects during methacholine challenge

    No full text
    The results of our study show that: 1) most healthy subjects may develop flow limitation and hyperinflation during methacoline challenge in supine position, and 2) at onset of flow limitation there is little or no dyspnea, suggesting that the onset of dynamic airways compression per se does not elicit significant dyspnea. Significant dyspnea probably occurs with marked dynamic hyperinflation
    • …
    corecore