17 research outputs found

    Effect of bacteria on pre-formed and nascent biofilms of Irpex lacteus

    Get PDF
    Fungal biofilms are applicable to removal of pollutants in biofilters in nonsterile conditions but the bacterial effect is poorly known. Interactions between fungal and bacterial organisms were investigated in preformed or nascent biofilms and the enzyme activities and degradation capacity measured. Different effects of Escherichia coli and Pseudomonas aeruginosa on degradation of an anthraquinone dye by fungal biofilms colonizing polyurethane foam (PUF) in the presence of bacteria (104-106 CFU) at pH 4.5 and 6 were observed in a 10-day experiment: the former bacterium inhibited degradation whereas the latter not. Production of peroxidases but not of laccase was reduced; the bacteria could not remove the dye. The fungal biomass amount colonizing PUF was unaffected by bacteria, E. coli and P. aeruginosa increased their respective counts by 1 to 3 and 0 to 2 orders of magnitude. In contrast, the degradation capacity (85-95% decolorization rate at pH 5.5) of preformed 1-week-old fungal biofilms colonizing PUF or pinewood was not affected by the added 106 CFU of E.coli in a 4-week experiment. The fungal growth was reduced 1.4-fold and bacterial counts increased up to 2-fold compared to bacterial controls. The results demonstrate a significant resistance of preformed I. lacteus biofilms to bacterial stress which is important for practical application.The work was supported by the project IAAX00200901

    Characteristics and outcomes of e-cigarette exposure incidents reported to 10 European Poison Centers: a retrospective data analysis

    Get PDF
    Background: The use of e-cigarettes has increased during the past few years. Exposure to e-cigarette liquids, whether intentional or accidental, may lead to adverse events our aim was to assess factors associated with e-cigarette exposures across European Union Member States (EU MS). Methods: A retrospective analysis of exposures associated with e-cigarettes reported to national poison centers was performed covering incidents from 2012 to March 2015 from 10 EU MS. De-identified and anonymous raw data was acquired. Results: In total, 277 incidents were reported. Unintentional exposure was the most frequently cited type of exposure (71.3%), while e-cigarette refill vials were responsible for the majority of the reported incidents (87.3%). Two-thirds of all exposures (67.5%) occurred as ingestion of e-liquids, which was more frequent among children (≤ 5 years, 6–18 years) compared to adults (87.0% vs. 59.3% vs. 57.6%, p < 0.001 respectively), exposure via the respiratory (5.4% vs. 22.2% vs. 22. 2%, p < 0.001) were more frequent among paediatric patients while ocular routes (2.2% vs. 3.7% vs. 11.4%, p = 0.021) were more frequent among adults. Logistic regression analyses indicated that paediatric incidents (≤ 5 years) were more likely to be through ingestion (adjusted Odds Ratio [aOR] = 4.36, 95% Confidence Interval [C.I.]: 1.87–10.18), but less likely to have a reported clinical effect (aOR = 0.41, 95% C.I.: 0.21–0.82). Conclusions: Our study highlighted parameters related to e-cigarette exposure incidents in 10 EU MS, the results of which indicate that consideration should be given to the design features which may mitigate risks, thereby protecting users, non-users and especially children

    Characteristics and outcomes of e-cigarette exposure incidents reported to 10 European Poison Centers : a retrospective data analysis

    Get PDF
    BACKGROUND: The use of e-cigarettes has increased during the past few years. Exposure to e-cigarette liquids, whether intentional or accidental, may lead to adverse events our aim was to assess factors associated with e-cigarette exposures across European Union Member States (EU MS). METHODS: A retrospective analysis of exposures associated with e-cigarettes reported to national poison centers was performed covering incidents from 2012 to March 2015 from 10 EU MS. De-identified and anonymous raw data was acquired. RESULTS: In total, 277 incidents were reported. Unintentional exposure was the most frequently cited type of exposure (71.3%), while e-cigarette refill vials were responsible for the majority of the reported incidents (87.3%). Two-thirds of all exposures (67.5%) occurred as ingestion of e-liquids, which was more frequent among children (≤ 5 years, 6-18 years) compared to adults (87.0% vs. 59.3% vs. 57.6%, p < 0.001 respectively), exposure via the respiratory (5.4% vs. 22.2% vs. 22.2%, p < 0.001) were more frequent among paediatric patients while ocular routes (2.2% vs. 3.7% vs. 11.4%, p = 0.021) were more frequent among adults. Logistic regression analyses indicated that paediatric incidents (≤ 5 years) were more likely to be through ingestion (adjusted Odds Ratio [aOR] = 4.36, 95% Confidence Interval [C.I.]: 1.87-10.18), but less likely to have a reported clinical effect (aOR = 0.41, 95% C.I.: 0.21-0.82). CONCLUSIONS: Our study highlighted parameters related to e-cigarette exposure incidents in 10 EU MS, the results of which indicate that consideration should be given to the design features which may mitigate risks, thereby protecting users, non-users and especially children
    corecore