36 research outputs found

    Diagnostic test accuracy of diabetic retinopathy screening by physician graders using a hand-held non-mydriatic retinal camera at a tertiary level medical clinic.

    Get PDF
    BACKGROUND: The evidence on diagnostic test accuracy (DTA) of diabetic retinopathy (DR) screening utilising photographic studies by non-ophthalmologist personnel in low and middle-income country (LMIC) settings is scarce. We aimed to assess DTA of DR screening using a nonmydriatic hand-held digital camera by trained general physicians in a non-ophthalmic setting. METHODS: This study is a validation of a screening intervention. We selected 700 people with diabetes (PwDM) > 18 years of age, not previously screened or treated for DR, presenting at a tertiary medical clinic in Sri Lanka. Two-field retinal imaging was used to capture fundus images before and after pupil dilatation, using a hand-held non-mydriatic (Visuscout 100®-Germany) digital retinal camera. The images were captured and graded by two trained, masked independent physician graders. The DTA of different levels of DR was assessed comparing physician's grading with a retinologist's clinical examination by mydriatic bio-microscopy, according to a locally adopted guideline. RESULTS: Seven hundred eligible PwDM were screened by physician graders. The mean age of participants was 60.8 years (SD ±10.08) and mean duration of DM was 9.9 years (SD ±8.09). Ungradable image proportion in non-mydriatic imaging was 43.4% (either eye-31.3%, both eyes 12.1%). This decreased to 12.8% (either eye-11.6%, both eyes-1.2%) following pupil dilatation. In comparison to detection of any level of DR, a referable level DR (moderate non-proliferative DR and levels above) showed a higher level of DTA. The sensitivity of the defined referable DR was 88.7% (95% CI 81.7-93.8%) for grader 1 (positive predictive value [PPV] 59.1%) and 92.5% (95% CI 86.4-96.5%) for grader 2 (PPV 68%), using mydriatic imaging, after including ungradable images as screen positives. The specificity was 94.9% (95% CI 93.6-96.0%) for grader 1 (negative predictive value [NPV] 99%) and 96.4% (95% CI 95.3-97.3%) for grader 2 (NPV 99.4%). CONCLUSIONS: The Physicians grading of images from a digital hand-held non-mydriatic camera at a medical clinic, with dilatation of pupil of those who have ungradable images, provides a valid modality to identify referable level of DR. This could be a feasible alternative modality to the existing opportunistic screening to improve the access and coverage. TRIAL REGISTRATION: Current Controlled Trials ISRCTN47559703 . Date of Registration 18th March 2019, Retrospectively registered

    Systematic review and meta-analysis of diagnostic accuracy of detection of any level of diabetic retinopathy using digital retinal imaging.

    Get PDF
    BACKGROUND: Visual impairment from diabetic retinopathy (DR) is an increasing global public health concern, which is preventable with screening and early treatment. Digital retinal imaging has become a preferred choice as it enables higher coverage of screening. The aim of this review is to evaluate how different characteristics of the DR screening (DRS) test impact on diagnostic test accuracy (DTA) and its relevance to a low-income setting. METHODS: We conducted a systematic literature search to identify clinic-based studies on DRS using digital retinal imaging of people with DM (PwDM). Summary estimates of different sub-groups were calculated using DTA values weighted according to the sample size. The DTA of each screening method was derived after exclusion of ungradable images and considering the eye as the unit of analysis. The meta-analysis included studies which measured DTA of detecting any level of DR. We also examined the effect on detection from using different combinations of retinal fields, pupil status, index test graders and setting. RESULTS: Six thousand six hundred forty-six titles and abstracts were retrieved, and data were extracted from 122 potentially eligible full reports. Twenty-six studies were included in the review, and 21 studies, mostly from high-income settings (18/21, 85.7%), were included in the meta-analysis. The highest sensitivity was observed in the mydriatic greater than two field strategy (92%, 95% CI 90-94%). The highest specificity was observed in greater than two field methods (94%, 95% CI 93-96%) where mydriasis did not affect specificity. Overall, there was no difference in sensitivity between non-mydriatic and mydriatic methods (86%, 95% CI 85-87) after exclusion of ungradable images. The highest DTA (sensitivity 90%, 95% CI 88-91%; specificity 95%, 95% CI 94-96%) was observed when screening was delivered at secondary/tertiary level clinics. CONCLUSIONS: Non-mydriatic two-field strategy could be a more pragmatic approach in starting DRS programmes for facility-based PwDM in low-income settings, with dilatation of the pupils of those who have ungradable images. There was insufficient evidence in primary studies to draw firm conclusions on how graders' background influences DTA. Conducting more context-specific DRS validation studies in low-income and non-ophthalmic settings can be recommended

    Systematic review on barriers and enablers for access to diabetic retinopathy screening services in different income settings.

    Get PDF
    BACKGROUND: Diabetic retinopathy (DR) can lead to visual impairment and blindness if not detected and treated in time. Knowing the barriers/enablers in advance in contrasting different country income settings may accelerate development of a successful DR screening (DRS) program. This would be especially applicable in the low-income settings with the rising prevalence of DR. OBJECTIVES: The aim of this systematic review is to identify and contrast the barriers/enablers to DRS for different contexts using both consumers i.e., people with diabetes (PwDM) and provider perspectives and system level factors in different country income settings. METHODS: We searched MEDLINE, Embase, CENTRAL in the Cochrane Library from the databases start date to December 2018. We included the studies reported on barriers and enablers to access DRS services based at health care facilities. We categorised and synthesized themes related to the consumers (individuals), providers and the health systems (environment) as main dimensions according to the constructs of social cognitive theory, supported by the quantitative measures i.e., odds ratios as reported by each of the study authors. MAIN RESULTS: We included 77 studies primarily describing the barriers and enablers. Most of the studies were from high income settings (72.7%, 56/77) and cross sectional in design (76.6%, 59/77). From the perspectives of consumers, lack of knowledge, attitude, awareness and motivation were identified as major barriers. The enablers were fear of blindness, proximity of screening facility, experiences of vision loss and being concerned of eye complications. In providers' perspectives, lack of skilled human resources, training programs, infrastructure of retinal imaging and cost of services were the main barriers. Higher odds of uptake of DRS services was observed when PwDM were provided health education (odds ratio (OR) 4.3) and having knowledge on DR (OR range 1.3-19.7). CONCLUSION: Knowing the barriers to access DRS is a pre-requisite in development of a successful screening program. The awareness, knowledge and attitude of the consumers, availability of skilled human resources and infrastructure emerged as the major barriers to access to DRS in any income setting

    Strategies to address inequity of uncorrected refractive error in the Western Pacific: A modified Delphi process.

    Get PDF
    PURPOSE: Uncorrected refractive error is the leading cause of vision impairment globally; however, little attention has been given to equity and access to services. This study aimed to identify and prioritise: (1) strategies to address inequity of access to refractive error services and (2) population groups to target with these strategies in five sub-regions within the Western Pacific. METHODS: We invited eye care professionals to complete a two-round online prioritisation process. In round 1, panellists nominated population groups least able to access refractive error services, and strategies to improve access. Responses were summarised and presented in round 2, where panellists ranked the groups (by extent of difficulty and size) and strategies (in terms of reach, acceptability, sustainability, feasibility and equity). Groups and strategies were scored according to their rank within each sub-region. RESULTS: Seventy five people from 17 countries completed both rounds (55% women). Regional differences were evident. Indigenous peoples were a priority group for improving access in Australasia and Southeast Asia, while East Asia identified refugees and Oceania identified rural/remote people. Across the five sub-regions, reducing out-of-pocket costs was a commonly prioritised strategy for refraction and spectacles. Australasia prioritised improving cultural safety, East Asia prioritised strengthening school eye health programmes and Oceania and Southeast Asia prioritised outreach to rural areas. CONCLUSION: These results provide policy-makers, researchers and funders with a starting point for context-specific actions to improve access to refractive error services, particularly among underserved population groups who may be left behind in existing private sector-dominated models of care

    Exploring the impact of health on agricultural labour productivity in Asia and Latin America-A Scoping Review

    No full text
    It is a scoping review to explore the general health of farmers and agricultural workers living in low and middle income countries of Asia and Latin America. Furthermore, the impact of health interventions done for these farmers on their productivity is explored as well
    corecore