5,189 research outputs found

    Exponential Mixing for a Stochastic PDE Driven by Degenerate Noise

    Full text link
    We study stochastic partial differential equations of the reaction-diffusion type. We show that, even if the forcing is very degenerate (i.e. has not full rank), one has exponential convergence towards the invariant measure. The convergence takes place in the topology induced by a weighted variation norm and uses a kind of (uniform) Doeblin condition.Comment: 10 pages, 1 figur

    Lack of Effect of Murine Norovirus Infection on a Mouse Model of Bacteria-Induced Colon Cancer

    Get PDF
    Murine norovirus (MNV) is endemic in mouse research facilities in the United States and Europe, with a prevalence as high as 58% to 64%. Because of MNV's orofecal route of infection, clinically silent persistent infections in some mouse strains, and proclivity for macrophage and dendritic cells, its presence in mouse colonies has potential to alter phenotypes in experimental mouse models, particularly those involving inflammation and immunologic responses. Although MNV is subclinical, not causing overt disease in immunocompetent mice, we found that MNV infection can accelerate bacteria-induced inflammatory bowel disease (IBD) progression in Mdr1a^(-/-) mice. The studies presented here examined whether MNV infection also affects the phenotype of a bacterially driven mouse model of inflammation-associated colon cancer in genetically susceptible Smad3^(-/-) mice. In vitro culture of bone-marrow—derived macrophages (BMDM) was used to determine whether MNV4 influenced macrophage cytokine production. For in vivo studies, Smad3-/- mice were infected with MNV4 one week prior to infection with Helicobacter. Mice were monitored for 17 to 32 wk for development of IBD and colon cancer, and tissues were analyzed histopathologically. Although in vitro infection of BMDM with MNV4 led to increased inflammatory cytokine production, infection with MNV4 in vivo did not result in any statistically significant differences in survival, IBD scores, tumor incidence, or tumor phenotype in Smad3^(-/-) mice. In addition, MNV infection alone did not result in IBD or colon cancer. Therefore MNV infection alone or in conjunction with Helicobacter does not alter the development or progression of IBD or colon cancer in Smad3^(-/-) mice

    Core-level photoemission spectroscopy of nitrogen bonding in GaNxAs1–x alloys

    Get PDF
    The nitrogen bonding configurations in GaNxAs1–x alloys grown by molecular beam epitaxy with 0.07=0.03, the nitrogen is found to exist in a single bonding configuration – the Ga–N bond; no interstitial nitrogen complexes are present. The amount of nitrogen in the alloys is estimated from the XPS using the N 1s photoelectron and Ga LMM Auger lines and is found to be in agreement with the composition determined by x-ray diffraction

    Neutrophil gelatinase-associated lipocalin: its response to hypoxia and association with acute mountain sickness.

    Get PDF
    Acute Mountain Sickness (AMS) is a common clinical challenge at high altitude (HA). A point-of-care biochemical marker for AMS could have widespread utility. Neutrophil gelatinase-associated lipocalin (NGAL) rises in response to renal injury, inflammation and oxidative stress. We investigated whether NGAL rises with HA and if this rise was related to AMS, hypoxia or exercise. NGAL was assayed in a cohort (n = 22) undertaking 6 hours exercise at near sea-level (SL); a cohort (n = 14) during 3 hours of normobaric hypoxia (FiO2 11.6%) and on two trekking expeditions (n = 52) to over 5000 m. NGAL did not change with exercise at SL or following normobaric hypoxia. During the trekking expeditions NGAL levels (ng/ml, mean ± sd, range) rose significantly (P < 0.001) from 68 ± 14 (60-102) at 1300 m to 183 ± 107 (65-519); 143 ± 66 (60-315) and 150 ± 71 (60-357) at 3400 m, 4270 m and 5150 m respectively. At 5150 m there was a significant difference in NGAL between those with severe AMS (n = 7), mild AMS (n = 16) or no AMS (n = 23): 201 ± 34 versus 171 ± 19 versus 124 ± 12 respectively (P = 0.009 for severe versus no AMS; P = 0.026 for mild versus no AMS). In summary, NGAL rises in response to prolonged hypobaric hypoxia and demonstrates a relationship to the presence and severity of AMS

    The gravitational wave rocket

    Get PDF
    Einstein's equations admit solutions corresponding to photon rockets. In these a massive particle recoils because of the anisotropic emission of photons. In this paper we ask whether rocket motion can be powered only by the emission of gravitational waves. We use the double series approximation method and show that this is possible. A loss of mass and gain in momentum arise in the second approximation because of the emission of quadrupole and octupole waves.Comment: 10 pages LaTe

    Photoluminescence spectroscopy of bandgap reduction in dilute InNAs alloys

    Get PDF
    Photoluminescence (PL) has been observed from dilute InNxAs1–x epilayers grown by molecular-beam epitaxy. The PL spectra unambiguously show band gap reduction with increasing N content. The variation of the PL spectra with temperature is indicative of carrier detrapping from localized to extended states as the temperature is increased. The redshift of the free exciton PL peak with increasing N content and temperature is reproduced by the band anticrossing model, implemented via a (5×5) k·p Hamiltonian

    Multiparametric prostate MRI quality assessment using a semi-automated PI-QUAL software program

    Get PDF
    The technical requirements for the acquisition of multiparametric magnetic resonance imaging (mpMRI) of the prostate have been clearly outlined in the Prostate Imaging Reporting and Data System (PI-RADS) guidelines, but there is still huge variability in image quality among centres across the world. It has been difficult to quantify what constitutes a good-quality image, and a first attempt to address this matter has been the publication of the Prostate Imaging Quality (PI-QUAL) score and its dedicated scoring sheet. This score includes the assessment of technical parameters that can be obtained from the DICOM files along with a visual evaluation of certain features on prostate MRI (e.g., anatomical structures). We retrospectively analysed the image quality of 10 scans from different vendors and magnets using a semiautomated dedicated PI-QUAL software program and compared the time needed for assessing image quality using two methods (semiautomated assessment versus manual filling of the scoring sheet). This semiautomated software is able to assess the technical parameters automatically, but the visual assessment is still performed by the radiologist. There was a significant reduction in the reporting time of prostate mpMRI quality according to PI-QUAL using the dedicated software program compared to manual filling (5'54″ versus 7'59″; p = 0.005). A semiautomated PI-QUAL software program allows the radiologist to assess the technical details related to the image quality of prostate mpMRI in a quick and reliable manner, allowing clinicians to have more confidence that the quality of mpMRI of the prostate is sufficient to determine patient care

    Struggling and juggling: a comparison of assessment loads in research and teaching-intensive universities

    Get PDF
    In spite of the rising tide of metrics in UK higher education, there has been scant attention paid to assessment loads, when evidence demonstrates that heavy demands lead to surface learning. Our study seeks to redress the situation by defining assessment loads and comparing them across research-and teaching intensive universities. We clarify the concept of ‘assessment load’ in response to findings about high volumes of summative assessment on modular degrees. We define assessment load across whole undergraduate degrees, according to four measures: the volume of summative assessment; volume of formative assessment; proportion of examinations to coursework; number of different varieties of assessment. All four factors contribute to the weight of an assessment load, and influence students’ approaches to learning. Our research compares programme assessment data from 73 programmes in 14 UK universities, across two institutional categories. Research-intensives have higher summative assessment loads and a greater proportion of examinations; teaching-intensives have higher varieties of assessment. Formative assessment does not differ significantly across both university groups. These findings pose particular challenges for students in different parts of the sector. Our study questions the wisdom that ‘more’ is always better, proposing that lighter assessment loads may make room for ‘slow’ and deep learning
    • 

    corecore