10 research outputs found

    Abdominal Aortic Aneurysm Morphology as an Essential Criterion for Stratifying the Risk of Aneurysm Rupture

    No full text
    The current stratification model of aneurysm rupture seems to be insufficient in some clinical cases. In our study, we determined the differences in wall structure between ruptured and unruptured aneurysms. We obtained computed tomography angiograms and categorized them into the following three groups, consisting of 49 patients each: the group with ruptured abdominal aortic aneurysms (rAAA), symptomatic (sAAA), and asymptomatic (aAAA). The three-dimensional AAA anatomy was digitally reconstructed for each patient through semi-automatically obtained segmentation, and each aneurysm was distinguished by the following three parameters: AFL (aneurysm flow lumen), ILT (intraluminal thrombus), and calcifications. The AFL volume was greater in rAAA compared with aAAA (p = 0.004), the ILT volume was greater in aAAA than in rAAA (p = 0.013), and the AFL/ILT surface ratio was bigger in rAAA than in aAAA (p < 0.001), sAAA than in aAAA (p = 0.033), and rAAA than in sAAA (p = 0.016). AFL/ILT surface*100 was defined as an independent predictive factor of rAAA to aAAA (OR 1.187; 95% CI 1.099–1.281), to sAAA (OR 1.045; 95% CI 1.004–1.087), and in sAAA vs. aAAA (OR 1.067; 95% CI 1.017–1.119). Consequently, the wall of rAAA differs significantly from unruptured aneurysms. The AFL/ILT surface ratio might indicate an increased risk of aneurysm rupture and the occurrence of symptoms in AAA

    Denosumab – a new medication in the treatment of postmenopausal osteoporosis

    No full text
    Osteoporosis is a chronic, systemic skeletal disorder characterised by decreased bone density. It leads to an increased risk of bone fractures – one of the major causes of disability in modern societies. Bisphosphonates are the most commonly used medications in the treatment of postmenopausal osteoporosis. Denosumab, a new approach to fracture prevention, is a fully human monoclonal antibody that targets nuclear factor-B ligand (RANKL), an important cytokine regulating formation and function of osteoclasts. Generally, denosumab is not used as initial therapy; however, in some cases it should be considered. It concerns patients at high risk of fracture, such as older patients who have difficulty with the dosing requirements of oral bisphosphonates or who have markedly impaired renal function. Denosumab can be also considered in patients who present intolerance or unresponsiveness to other therapies. Clinical studies have shown that denosumab is highly effective in increasing bone mineral density (BMD) in postmenopausal women regardless of the site analysed, as well as reducing the risk of bone fractures. The risk of developing antiresorptive, agent-induced osteonecrosis of the jaw related to denosumab therapy is low

    Simulation and Training of Needle Puncture Procedure with a Patient-Specific 3D Printed Gluteal Artery Model

    No full text
    The puncture of the gluteal artery (GA) is a rare and difficult procedure. Less experienced clinicians do not always have the opportunity to practice and prepare for it, which creates a need for novel training tools. We aimed to investigate the feasibility of developing a 3D-printed, patient-specific phantom of the GA and its surrounding tissues to determine the extent to which the model can be used as an aid in needle puncture planning, simulation, and training. Computed tomography angiography scans of a patient with an endoleak to an internal iliac artery aneurysm with no intravascular antegrade access were processed. The arterial system, including the superior GA with its division branches, and pelvic area bones were 3D printed. The 3D model was embedded in the buttocks-shaped, patient-specific mold and cast. The manufactured, life-sized phantom was used to simulate the GA puncture procedure and was validated by 13 endovascular specialists. The printed GA was visible in the fluoroscopy, allowing for a needle puncture procedure simulation. The contrast medium was administered, simulating a digital subtraction angiography. Participating doctors suggested that the model could make a significant impact on preprocedural planning and resident training programs. Although the results are promising, we recommend that further studies be used to adjust the design and assess its clinical value

    Initial Experience with Fenestrated Physician-Modified Stent Grafts Using 3D Aortic Templates

    No full text
    The goal of this study was to describe the surgical results of physician-modified endografts (PMEG) utilizing a 3D aortic template in a center with no prior experience in complex endovascular aortic repairs. Forty-three patients underwent physician-modified graft stent implantation using a 3D aortic model. The inclusion criteria were juxtarenal and suprarenal aortic aneurysms, type IV thoracoabdominal aneurysms, and type IA endoleak after endovascular aortic repair. In asymptomatic patients, the diameter threshold for aneurysm repair was 5.5 cm in males and 5.0 cm in females. 3D aortic templates were prepared from the patient’s computed tomography angiography scans and sterilized before use in the operating suite. Forty-three stent grafts were modified with the use of a 3D printing template. A total of 162 reinforced fenestrations (37 celiac, 43 right renal, 39 left renal, 43 superior mesenteric) with a mean of 3.8 per patient were performed. All PMEGs had a posterior reducing-diameter tie and a preloaded guidewire. The mean modification time was 86 ± 12 min. The mean follow-up was 14 ± 12 months. The 30-day mortality was 12%. During the follow-up period, the patency rate was 95% per the superior mesenteric artery, 93% per right renal artery, 95% per left renal artery, and 89% per celiac trunk. Twelve (28%) patients had endoleak, of which type I or III was present in 5 (12%) patients, and type II in 7 (16%). 3D printing can be successfully integrated into the physician’s everyday practice of stent graft modification. However, the use of this approach in centers without experience performing complex aortic procedures results in worse surgical metrics than those previously reported

    The Influence of Individualized Three-Dimensional Holographic Models on Patients’ Knowledge Qualified for Intervention in the Treatment of Peripheral Arterial Disease (PAD)

    No full text
    We sought to determine the role of the patient-specific, three-dimensional (3D) holographic vascular model in patient medical knowledge and its influence on obtaining a more conscious informed consent process for percutaneous balloon angioplasty (PTA). Patients with peripheral arterial disease who had been scheduled for PTA were enrolled in the study. Information regarding the primary disease, planned procedure, and informed consent was recorded in typical fashion. Subsequently, the disease and procedure details were presented to the patient, showing the patients their individual model. A patient and medical supervisor equipped with mixed reality headsets could both simultaneously manipulate the hologram using gestures. The holographic 3D model had been created on a scale of 1:1 based on computed tomography scans. The patient’s knowledge was tested by the completion of a questionnaire before and after the interaction in a mixed reality environment. Seventy-nine patients manipulated arterial holograms in mixed reality head-mounted devices. Before the 3D holographic artery model interaction, the mean ± standard deviation score of the knowledge test was 2.95 ± 1.21 points. After the presentation, the score had increased to 4.39 ± 0.82, with a statistically significant difference (p = 0.0000) between the two scores. Using a Likert scale from 1 to 5, the patients had scored the use of the 3D holographic model at 3.90 points regarding its usefulness in comprehending their medical condition; at 4.04 points regarding the evaluation of the holograms as helpful in understanding the course of surgery; and rated the model at 1.99 points in reducing procedure-related stress. Using a nominal scale (know or don’t know), the patients had self-assessed their knowledge of the procedure before and after the 3D model presentation, with a score of 6.29 ± 2.01 and 8.39 ± 1.54, respectively. The study group tolerated the use of head-mounted devices. Only one patient had nausea and dizziness, while four patients experienced transient eye pain. The 3D holographic arterial model aided in the understanding of patients’ knowledge regarding the disease and procedure, making the informed consent process more conscious. The holograms improved the patient’s self-consciousness. Mixed reality headset-related complications were rare and within acceptable rates

    Effects of Sterilization Methods on Different 3D Printable Materials for Templates of Physician-Modified Aortic Stent Grafts Used in Vascular Surgery—A Preliminary Study

    No full text
    Three-dimensionally-printed aortic templates are increasingly being used to aid in the modification of stent grafts in the treatment of urgent, complex aortic disorders, often of an emergency nature. The direct contact between the aortic template and the stent graft implies the necessity of complete sterility. Currently, the efficacy of sterilizing aortic templates and the effect of sterilization on the geometry of tubular aortic models are unknown. A complex case of aortic arch dissection was selected to prepare a 3D-printed aortic arch template, which was then manufactured in six popular printing materials: polylactic acid (PLA), nylon, polypropylene (PP), polyethylene terephthalate glycol (PETG), and a rigid and flexible photopolymer resin using fused deposition modeling (FDM) and stereolithography (SLA). The 3D models were contaminated with Geobacillus stearothermophilus broth and Bacillus atrophaeus. The sterilization was performed using three different methods: heat (105 °C and 121 °C), hydrogen peroxide plasma, and ethylene oxide gas. Before and after sterilization, the aortic templates were scanned using computed tomography to detect any changes in their morphology by comparing the dimensions. All sterilization methods were effective in the elimination of microorganisms. Steam sterilization in an autoclave at 121 °C caused significant deformation of the aortic templates made of PLA, PETG, and PP. The other materials had stable geometries, and changes during mesh comparisons were found to be submillimeter. Similarly, plasma, gas, and heat at 105 °C did not change the shapes of aortic templates observed macroscopically and using mesh analysis. All mean geometry differences were smaller than 0.5 mm. All sterilization protocols tested in our study were equally effective in destroying microorganisms; however, differences occurred in the ability to induce 3D object deformation. Sterilization at high temperatures deformed aortic templates composed of PLA, PETG, and PP. This method was suitable for nylon, flexible, and rigid resin-based models. Importantly, plasma and gas sterilization were appropriate for all tested printing materials, including PLA, PETG, PP, nylon, flexible and rigid resins. Moreover, sterilization of all the printed models using our novel protocol for steam autoclaving at 105 °C was also 100% effective, which could represent a significant advantage for health centers, which can therefore use one of the most popular and cheap methods of medical equipment disinfection for the sterilization of 3D models as well

    Impact of Carotid Endarterectomy on Choroidal Thickness and Volume in Enhanced Depth Optical Coherence Tomography Imaging

    No full text
    Purpose. Carotid endarterectomy (CEA) is considered an effective therapeutic method for improving ocular circulation. The choroid is a predominantly vascular tissue; thus, systemic and local vascular alterations may influence its morphology and function. The aim of the current study was to analyse changes in choroidal thickness and volume in patients with significant internal carotid artery stenosis (ICAS) before and after unilateral CEA. Methods. The 42 eyes of the 21 asymptomatic patients included in the study were divided into two groups: those ipsilateral (EIE) and those contralateral (ECE) to CEA. All participants underwent a complete ophthalmologic examination, including enhanced depth imaging-optical coherence tomography (EDI-OCT). A comparative analysis of subfoveal thickness (CT) and choroidal volume (CV) measured in nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields at baseline, on the 2nd day after CEA, and in the 3rd month after CEA was performed. Results. In the EIE and ECE groups, no significant differences in either CT or CV values before and on the 2nd day after the CEA were observed. In the EIE group, a significant increase in CT and CV in the 3rd month after CEA compared to baseline was noted in the specific ETDRS region. Changes in CT and CV after surgery were positively correlated with the participants’ physical activity status and diastolic blood pressure and negatively correlated with the participants’ age and smoking status. Additionally, the analysis of changes in CV after CEA showed a positive correlation between the EIE and ECE groups. Conclusions. CT and CV fluctuations in the central and perifoveal areas visualized with EDI-OCT enabled the observation of the processes of tissue adaptation to variable blood flow conditions
    corecore