9 research outputs found

    The role of frequency doubling perimetry in the diagnosis of glaucoma: screening in employees of a public hospital in an urban area of São Paulo

    Get PDF
    PURPOSE: To study the prevalence of glaucoma in employees of a public hospital in São Paulo and to analyze the role of frequency doubling perimetry along with non-contact tonometry and direct ophthalmoscopy, in the screening for glaucoma. METHODS: 612 employees of the Central Hospital of the Santa Casa de São Paulo were evaluated from October 15 to 20, 2000; 438 were women and 174 men, with mean age of 45.05±7.7 years (range, 35 to 81 years); 437 were white, 104 mulatto, 43 black and 28 Asian. All examinations were done by 10 eye specialists with experience in glaucoma. All employees had both eyes examined, by means of frequency doubling perimetry (FDT), ophthalmoscopy (FO), and non-contact tonometry (TNC). RESULTS: 159 (25.98%) subjects presented with at least one abnormal testing; 5 (3.14%) had high IOP (TNC+); 13 (8.17%) presented suspicious disk (FO+); 110 (69.18%) presented abnormal FDT (FDP+); 8 (5.03%) TNC+ and FO+; 10 (6.28%) had TNC+ and FDT+; 9 (5.66%) presented FO+ and FDT+; 4 (2.51%) had TNC+, FO+ and FDT+; 12 (1.96%) individuals were diagnosed with glaucoma, four of whom (0.65%), with normal pressure glaucoma. CONCLUSIONS: Frequency doubling perimetry was found to be an important step in the screening for glaucoma in the study. Of the 12 individuals that had the diagnosis of glaucoma, 5 (41.6%) would not have been diagnosed if they had not undergone frequency doubling perimetry.OBJETIVO: Estudar a prevalência de glaucoma, em funcionários da Santa Casa de Misericórdia de São Paulo e analisar a validade da inclusão da perimetria de freqüência dupla junto à tonometria de não-contato e à oftalmoscopia direta, na triagem para glaucoma. MÉTODOS: Foram examinados 612 funcionários voluntários, 438 mulheres e 174 homens, com idade média de 45,05±7,7 anos. Eram 437 da raça branca, 104 mulatos, 43 da raça negra e 28 da raça amarela. Todos os funcionários tiveram ambos os olhos examinados por especialistas em glaucoma, que realizaram os seguintes exames: perimetria de freqüência dupla (FDT), oftalmoscopia direta (FO), tonometria de não-contato (TNC). RESULTADOS: Dos 612 indivíduos triados, 159 (25,98%) apresentaram alguma anormalidade em pelo menos um dos exames: 5 (3,14%) apresentaram pressão intra-ocular elevada (TNC+); 13 (8,17%) apresentaram oftalmoscopia suspeita (FO+); 110 (69,18%) apresentaram perimetria de freqüência dupla alterado (FDT+); 8 (5,03%) TNC+ e FO+; 10 (6,28%) TNC+ e FDT+; 9 (5,66%) FO+ e FDT+; 4 (2,51%) TNC+, FO+ e FDT+. Foram detectados 12 (1,96%) indivíduos com glaucoma, quatro dos quais (0,65%) com glaucoma de pressão normal. CONCLUSÕES: A perimetria de freqüência dupla mostrou-se útil para o rastreamento de glaucoma dentro da amostragem estudada. Do total de 12 indivíduos que tiveram o diagnóstico de glaucoma, 5 (41,6%) não teriam sido detectados se não tivessem sido submetidos a perimetria de freqüência dupla.Santa Casa de São Paulo Departamento de OftalmologiaSanta Casa de Misericórdia de São Paulo Departamento de Oftalmologia Setor de GlaucomaUniversidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaSanta Casa de São Paulo Faculdade de Ciências Médicas Departamento de OftalmologiaUNIFESP, Depto. de OftalmologiaSciEL

    Internal revision of Simmons: analysis of his clinical results and complications

    No full text
    INTRODUÇÃO: É importante estudar a efetividade da trabeculectomia e estratégias para manter sua ação ao longo do tempo. Para melhorarmos o prognóstico das revisões cirúrgicas é imprescindível entendermos melhor a estrutura da bolha filtrante e suas possíveis causas de falência. Formas alternativas para se restabelecer a drenagem e o funcionamento da trabeculectomia não funcionante foram desenvolvidas, entre elas a Revisão Interna de Simmons. OBJETIVOS: Avaliar os efeitos da Revisão Interna de Simmons sobre a PIO; sobre o aspecto biomicroscópico da bolha no pós-operatório e sua correlação com achados biométricos obtidos pela biomicroscopia ultra-sônica. CASUÍSTICA E MÉTODOS: Foram incluídos e estudados de forma prospectiva por 6 meses, 29 pacientes portadores de glaucoma primário, submetidos a trabeculectomia prévia,há pelo menos três meses, que apresentavam PIO acima do esperado para o controle do glaucoma, apesar de medicação hipotensora utilizada. Foram fatores de inclusão a conjuntiva livre e o óstio interno da trabeculectomia patente à gonioscopia. O critério de sucesso foi: abaixamento da PIO, igual ou maior que 30% da PIO em relação à PIO pré-operatória e/ou pressão final menor ou igual a 15mmHg, com ou sem medicação antiglaucomatosa associada. RESULTADOS: Houve uma queda estatisticamente significante da PIO e do número de medicações utilizadas após a cirurgia. A PIO média antes da operação era de 23,72 ± 4,10 mmHg e ao término do estudo, de 15,04 ± 4,00 mmHg (p=0,000016). A média das pressões da curva tonométrica antes da cirurgia era de 22,36 ± 3,91mmHg, caindo para 15,01 ± 3,95mmHg no PO180d (p=0,0000001). Antes da cirurgia, a média do número de medicações usadas era de 2,1 ± 0,77 e ao término do estudo, 1,22 ± 1,01 (p=0,001117). Houve um aumento do tamanho da bolha filtrante, avaliado pela biomicroscopia. As bolhas apresentaram altura média de 0,28 ± 0,65 e terminaram o estudo com altura de 0,78 ± 0,85 (p=0,000016). Não houve diferença na altura da bolha, medida pela biomicroscopia ultra-sônica após a cirurgia. A pressão intra-ocular apresentou relação inversamente proporcional à dimensão da bolha filtrante, com significância estatística. As complicações mais encontradas foram: descolamento da membrana de Descemet, no local da incisão principal em 5 doentes (17,2%), abertura inadvertida da conjuntiva em 4 (13,8%), e descolamento de coróide, em 3 (10,3%). CONCLUSÕES: A Revisão Interna de Simmons proporcionou diminuição de 30% da PIO em 52% dos pacientes e redução do número de medicações antiglaucomatosas associadas, quando utilizadas. As bolhas se mostraram-se estatisticamente maiores após o procedimento. Houve uma correlação perfeita entre a classificação da altura da bolha entre a medida biomicroscópica baseada na escala de Indiana e a biométrica obtida pela biomicroscopia ultra-sônica. Não houve aplanamento da curva tonométrica apesar desta ter diminuído 32%. Não foi observada mudança significativa no vício de refração ou na acuidade visual após a operação. A biomicroscopia ultra-sônica demonstrou uma associação inversa entre um maior número de complicações pós-operatórias e o tamanho menor do óstio interno da trabeculectomia.INTRODUCTION: It is important to study the trabeculectomy effectiveness and strategies to keep its action within long time. To improve the prognostic presented on glaucoma surgical reviews it is essential to understand better the bleb structure and its possible cause of failing. Alternative ways of restoring the drainage and the good performance of trabeculectomy have been studied, among them the Internal Revision of Simmons. PURPOSE: Evaluate the surgery effects on the IOP; on the biomicroscopic aspect of the bleb and its co-relation with biometric founding gotten through UBM. METHODS: For six months, 29 patients with open angle glaucoma who had been submitted to trabeculectomy before, for at least three months, with IOP above the expected to the control of glaucoma, despite the medication used, were included and studied in a prospective way. These patients should present the conjunctive tissue not too scarry and internal ostio of trabeculectomy present on the gonioscopia. The success criterion was: lowering the IOP, equal or above 30% on pre-operatory IOP and/or final pressure below 15 mmHg, with or without eye drops. RESULTS: There was a statistically fall of IOP and amount of medication used after the surgery. The average of IOP before surgery was 23.27 ± 4.10 mmHg and at the end of study was 15.04 ± 4.00 mmHg (p=0.000016). The average of the IOP curve pressure before surgery was 22.36 ± 3.91mmHg, dropped to 15.01 ± 4.0 mmHg at PO180d (p=0.0000001). Before the surgery the average of medication used was 2.1 ± 0.77 and at the end of the study it was 1.22 ± 1.01 (p=0.001117). There was an increase of the filtering bleb size clinically measured. The blebs had an average height of 0.28 ± 0.65 and at the end of the study their height was 0.78 ± 0.85 (p=0.000016). The UBM didn?t show any difference in the bleb size. The intra-ocular pressure presented an inversely proportional relation to the dimension of the filtering bleb, with statistic significance. The most frequently problems found were: detachment of Descemet membrane where the main incision was performed, in 5 (17.28%) patients; hole in the conjuntiva in 4 (13.88%), detachment of the choroid in 3 (10.38%). CONCLUSIONS: The surgery was effective, for provided 30% decrease of initial IOP in 52% without or with eye drops statistically in small number than in presurgery. The blebs have appeared, statistically, bigger after the procedure. There was a perfect correlation between the bleb height classification, within the clinical measurement, based on the Indian scale, and the biometric one, gotten by UBM. There was no flattening of the IOP curve pressure despite this one had been 32% lower than the initial one. No significant change has occurred in the vicious of refraction or in the visual accuracy after the surgery. The UBM demonstrated an association between a larger number of complications post-surgery and the internal size of the trabeculectomy ostio

    Internal revision of Simmons: analysis of his clinical results and complications

    No full text
    INTRODUÇÃO: É importante estudar a efetividade da trabeculectomia e estratégias para manter sua ação ao longo do tempo. Para melhorarmos o prognóstico das revisões cirúrgicas é imprescindível entendermos melhor a estrutura da bolha filtrante e suas possíveis causas de falência. Formas alternativas para se restabelecer a drenagem e o funcionamento da trabeculectomia não funcionante foram desenvolvidas, entre elas a Revisão Interna de Simmons. OBJETIVOS: Avaliar os efeitos da Revisão Interna de Simmons sobre a PIO; sobre o aspecto biomicroscópico da bolha no pós-operatório e sua correlação com achados biométricos obtidos pela biomicroscopia ultra-sônica. CASUÍSTICA E MÉTODOS: Foram incluídos e estudados de forma prospectiva por 6 meses, 29 pacientes portadores de glaucoma primário, submetidos a trabeculectomia prévia,há pelo menos três meses, que apresentavam PIO acima do esperado para o controle do glaucoma, apesar de medicação hipotensora utilizada. Foram fatores de inclusão a conjuntiva livre e o óstio interno da trabeculectomia patente à gonioscopia. O critério de sucesso foi: abaixamento da PIO, igual ou maior que 30% da PIO em relação à PIO pré-operatória e/ou pressão final menor ou igual a 15mmHg, com ou sem medicação antiglaucomatosa associada. RESULTADOS: Houve uma queda estatisticamente significante da PIO e do número de medicações utilizadas após a cirurgia. A PIO média antes da operação era de 23,72 ± 4,10 mmHg e ao término do estudo, de 15,04 ± 4,00 mmHg (p=0,000016). A média das pressões da curva tonométrica antes da cirurgia era de 22,36 ± 3,91mmHg, caindo para 15,01 ± 3,95mmHg no PO180d (p=0,0000001). Antes da cirurgia, a média do número de medicações usadas era de 2,1 ± 0,77 e ao término do estudo, 1,22 ± 1,01 (p=0,001117). Houve um aumento do tamanho da bolha filtrante, avaliado pela biomicroscopia. As bolhas apresentaram altura média de 0,28 ± 0,65 e terminaram o estudo com altura de 0,78 ± 0,85 (p=0,000016). Não houve diferença na altura da bolha, medida pela biomicroscopia ultra-sônica após a cirurgia. A pressão intra-ocular apresentou relação inversamente proporcional à dimensão da bolha filtrante, com significância estatística. As complicações mais encontradas foram: descolamento da membrana de Descemet, no local da incisão principal em 5 doentes (17,2%), abertura inadvertida da conjuntiva em 4 (13,8%), e descolamento de coróide, em 3 (10,3%). CONCLUSÕES: A Revisão Interna de Simmons proporcionou diminuição de 30% da PIO em 52% dos pacientes e redução do número de medicações antiglaucomatosas associadas, quando utilizadas. As bolhas se mostraram-se estatisticamente maiores após o procedimento. Houve uma correlação perfeita entre a classificação da altura da bolha entre a medida biomicroscópica baseada na escala de Indiana e a biométrica obtida pela biomicroscopia ultra-sônica. Não houve aplanamento da curva tonométrica apesar desta ter diminuído 32%. Não foi observada mudança significativa no vício de refração ou na acuidade visual após a operação. A biomicroscopia ultra-sônica demonstrou uma associação inversa entre um maior número de complicações pós-operatórias e o tamanho menor do óstio interno da trabeculectomia.INTRODUCTION: It is important to study the trabeculectomy effectiveness and strategies to keep its action within long time. To improve the prognostic presented on glaucoma surgical reviews it is essential to understand better the bleb structure and its possible cause of failing. Alternative ways of restoring the drainage and the good performance of trabeculectomy have been studied, among them the Internal Revision of Simmons. PURPOSE: Evaluate the surgery effects on the IOP; on the biomicroscopic aspect of the bleb and its co-relation with biometric founding gotten through UBM. METHODS: For six months, 29 patients with open angle glaucoma who had been submitted to trabeculectomy before, for at least three months, with IOP above the expected to the control of glaucoma, despite the medication used, were included and studied in a prospective way. These patients should present the conjunctive tissue not too scarry and internal ostio of trabeculectomy present on the gonioscopia. The success criterion was: lowering the IOP, equal or above 30% on pre-operatory IOP and/or final pressure below 15 mmHg, with or without eye drops. RESULTS: There was a statistically fall of IOP and amount of medication used after the surgery. The average of IOP before surgery was 23.27 ± 4.10 mmHg and at the end of study was 15.04 ± 4.00 mmHg (p=0.000016). The average of the IOP curve pressure before surgery was 22.36 ± 3.91mmHg, dropped to 15.01 ± 4.0 mmHg at PO180d (p=0.0000001). Before the surgery the average of medication used was 2.1 ± 0.77 and at the end of the study it was 1.22 ± 1.01 (p=0.001117). There was an increase of the filtering bleb size clinically measured. The blebs had an average height of 0.28 ± 0.65 and at the end of the study their height was 0.78 ± 0.85 (p=0.000016). The UBM didn?t show any difference in the bleb size. The intra-ocular pressure presented an inversely proportional relation to the dimension of the filtering bleb, with statistic significance. The most frequently problems found were: detachment of Descemet membrane where the main incision was performed, in 5 (17.28%) patients; hole in the conjuntiva in 4 (13.88%), detachment of the choroid in 3 (10.38%). CONCLUSIONS: The surgery was effective, for provided 30% decrease of initial IOP in 52% without or with eye drops statistically in small number than in presurgery. The blebs have appeared, statistically, bigger after the procedure. There was a perfect correlation between the bleb height classification, within the clinical measurement, based on the Indian scale, and the biometric one, gotten by UBM. There was no flattening of the IOP curve pressure despite this one had been 32% lower than the initial one. No significant change has occurred in the vicious of refraction or in the visual accuracy after the surgery. The UBM demonstrated an association between a larger number of complications post-surgery and the internal size of the trabeculectomy ostio
    corecore