47 research outputs found

    MRSA Causing Infections in Hospitals in Greater Metropolitan New York: Major Shift in the Dominant Clonal Type Between 1996 and 2014

    Get PDF
    A surveillance study in 1996 identified the USA100 clone (ST5/SCCmecII)-also known as the New York/Japan clone-as the most prevalent MRSA causing infections in 12 New York City hospitals. Here we update the epidemiology of MRSA in seven of the same hospitals eighteen years later in 2013/14. Most of the current MRSA isolates (78 of 121) belonged to the MRSA clone USA300 (CC8/SCCmecIV) but the USA100 clone-dominant in the 1996 survey-still remained the second most frequent MRSA (25 of the 121 isolates) causing 32% of blood stream infections. The USA300 clone was most common in skin and soft tissue infections (SSTIs) and was associated with 84.5% of SSTIs compared to 5% caused by the USA100 clone. Our data indicate that by 2013/14, the USA300 clone replaced the New York/Japan clone as the most frequent cause of MRSA infections in hospitals in Metropolitan New York. In parallel with this shift in the clonal type of MRSA, there was also a striking change in the types of MRSA infections from 1996 to 2014

    Antibacterial cleaning products and drug resistance

    Get PDF
    http://deepblue.lib.umich.edu/bitstream/2027.42/55419/1/Aiello A, Antibacterial cleaning products and drug resistance, 2005.pd

    Transfusion-Associated Babesiosis after Heart Transplant

    Get PDF
    We describe a 54-year-old spleen-intact man with transfusion-associated Babesia microti infection after a heart transplant. Adult respiratory distress syndrome developed in the patient, and he required mechanical ventilation. Our experiences with this patient suggest that babesiosis should be considered in the differential diagnosis of transplant patients who have fever and hemolytic anemia

    Molecular characterization of hand flora and environmental isolates in a community setting

    Full text link
    http://deepblue.lib.umich.edu/bitstream/2027.42/55436/1/Pancholi P, Molecular characterization of hand flora and environmental isolates in a community setting, 2005.pd

    MRSA Causing Infections in Hospitals in Greater Metropolitan New York: Major Shift in the Dominant Clonal Type between 1996 and 2014

    Get PDF
    A surveillance study in 1996 identified the USA100 clone (ST5/SCCmecII)–also known as the “New York/Japan” clone—as the most prevalent MRSA causing infections in 12 New York City hospitals. Here we update the epidemiology of MRSA in seven of the same hospitals eighteen years later in 2013/14. Most of the current MRSA isolates (78 of 121) belonged to the MRSA clone USA300 (CC8/SCCmecIV) but the USA100 clone–dominant in the 1996 survey–still remained the second most frequent MRSA (25 of the 121 isolates) causing 32% of blood stream infections. The USA300 clone was most common in skin and soft tissue infections (SSTIs) and was associated with 84.5% of SSTIs compared to 5% caused by the USA100 clone. Our data indicate that by 2013/14, the USA300 clone replaced the New York/Japan clone as the most frequent cause of MRSA infections in hospitals in Metropolitan New York. In parallel with this shift in the clonal type of MRSA, there was also a striking change in the types of MRSA infections from 1996 to 2014
    corecore