    Heavy ion beam probing conceptual design for the Globus-M2 tokamak

    Get PDF
    The paper discusses the application of the heavy ion beam probe (HIBP) diagnostic to the Globus-M2 spherical tokamak. Probing beam trajectory calculations were conducted to find the optimal position for HIBP primary and secondary beam-linesin the realistic machine geometry. Three configurations of the vacuum vessel ports of Globus-M2 were considered for the regime with toroidal magnetic field Btor=0.7 T and plasma current Ipl=0.5 MA. The optimal probing scheme with the widest area of the plasma cross-section covered by the detector grid was selected. For this scheme, the secondary beam-line was proposed.Розглянута ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ встановлСння діагностики ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² Π½Π° сфСричний Ρ‚ΠΎΠΊΠ°ΠΌΠ°ΠΊ Глобус-М2. Для визначСння ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ полоТСння ΠΏΠ΅Ρ€Π²ΠΈΠ½Π½ΠΎΠ³ΠΎ Ρ– Π²Ρ‚ΠΎΡ€ΠΈΠ½Π½ΠΎΠ³ΠΎ Ρ–ΠΎΠ½ΠΎΠΏΡ€ΠΎΠ²ΠΎΠ΄Ρ–Π² HIBP Π±ΡƒΠ»ΠΈ ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½Ρ– Ρ€ΠΎΠ·Ρ€Π°Ρ…ΡƒΠ½ΠΊΠΈ Ρ‚Ρ€Π°Ρ”ΠΊΡ‚ΠΎΡ€Ρ–ΠΉ Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π· урахуванням Ρ€Π΅Π°Π»ΡŒΠ½ΠΎΡ— Π³Π΅ΠΎΠΌΠ΅Ρ‚Ρ€Ρ–Ρ— установки. Розглянуто Ρ‚Ρ€ΠΈ Π²Π°Ρ€Ρ–Π°Π½Ρ‚ΠΈ Π²Ρ…Ρ–Π΄Π½ΠΈΡ… ΠΏΠ°Ρ‚Ρ€ΡƒΠ±ΠΊΡ–Π² Ρ‚Π° Ρ€Π΅ΠΆΠΈΠΌ Π· Ρ‚ΠΎΡ€ΠΎΡ—Π΄Π°Π»ΡŒΠ½ΠΈΠΌ ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΈΠΌ ΠΏΠΎΠ»Π΅ΠΌ Btor=0,7 Π’Π» Ρ‚Π° струмом ΠΏΠ»Π°Π·ΠΌΠΈ Ipl=0,5 MA. ΠžΠ±Ρ€Π°Π½ΠΎ ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½Ρƒ схСму зондування, Ρ‰ΠΎ Π·Π°Π±Π΅Π·ΠΏΠ΅Ρ‡ΡƒΡ” ΠΌΠ°ΠΊΡΠΈΠΌΠ°Π»ΡŒΠ½Ρƒ ΠΏΠ»ΠΎΡ‰Ρƒ покриття Π²Π΅Ρ€Ρ‚ΠΈΠΊΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΏΠ΅Ρ€Π΅Ρ€Ρ–Π·Ρƒ ΠΏΠ»Π°Π·ΠΌΠΈ Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Π½ΠΎΡŽ ΡΡ–Ρ‚ΠΊΠΎΡŽ, Ρ– конфігурація Π²Ρ‚ΠΎΡ€ΠΈΠ½Π½ΠΎΠ³ΠΎ Ρ–ΠΎΠ½ΠΎΠΏΡ€ΠΎΠ²ΠΎΠ΄Ρƒ.РассмотрСна Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ установки диагностики ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² Π½Π° сфСричСский Ρ‚ΠΎΠΊΠ°ΠΌΠ°ΠΊ Глобус-М2. Для опрСдСлСния ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ полоТСния ΠΏΠ΅Ρ€Π²ΠΈΡ‡Π½ΠΎΠ³ΠΎ ΠΈ Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½ΠΎΠ³ΠΎ ΠΈΠΎΠ½ΠΎΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΎΠ² HIBP Π±Ρ‹Π»ΠΈ ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½Ρ‹ расчСты Ρ‚Ρ€Π°Π΅ΠΊΡ‚ΠΎΡ€ΠΈΠΉ Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰Π΅Π³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° с ΡƒΡ‡Π΅Ρ‚ΠΎΠΌ Ρ€Π΅Π°Π»ΡŒΠ½ΠΎΠΉ Π³Π΅ΠΎΠΌΠ΅Ρ‚Ρ€ΠΈΠΈ установки. РассмотрСны Ρ‚Ρ€ΠΈ Π²Π°Ρ€ΠΈΠ°Π½Ρ‚Π° Π²Ρ…ΠΎΠ΄Π½Ρ‹Ρ… ΠΏΠ°Ρ‚Ρ€ΡƒΠ±ΠΊΠΎΠ² ΠΈ Ρ€Π΅ΠΆΠΈΠΌ с Ρ‚ΠΎΡ€ΠΎΠΈΠ΄Π°Π»ΡŒΠ½Ρ‹ΠΌ ΠΌΠ°Π³Π½ΠΈΡ‚Π½Ρ‹ΠΌ ΠΏΠΎΠ»Π΅ΠΌ Btor=0,7 Π’Π» ΠΈ Ρ‚ΠΎΠΊΠΎΠΌ ΠΏΠ»Π°Π·ΠΌΡ‹ Ipl=0,5 MA. Π’Ρ‹Π±Ρ€Π°Π½Ρ‹ ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½Π°Ρ схСма зондирования, ΠΎΠ±Π΅ΡΠΏΠ΅Ρ‡ΠΈΠ²Π°ΡŽΡ‰Π°Ρ ΠΌΠ°ΠΊΡΠΈΠΌΠ°Π»ΡŒΠ½ΡƒΡŽ ΠΏΠ»ΠΎΡ‰Π°Π΄ΡŒ покрытия Π²Π΅Ρ€Ρ‚ΠΈΠΊΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ сСчСния ΠΏΠ»Π°Π·ΠΌΡ‹ Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Π½ΠΎΠΉ сСткой, ΠΈ конфигурация Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½ΠΎΠ³ΠΎ ΠΈΠΎΠ½ΠΎΠΏΡ€ΠΎΠ²ΠΎΠ΄Π°

    High voltage test bench for heavy ion beam probe diagnostics on T-15MD tokamak

    Get PDF
    D-shaped tokamak T-15MD is nowunder construction in the NRC β€œKurchatov Institute”. Heavy ion beam probing (HIBP) is an important part of T-15MD diagnostic system. Calculations of the probing ions trajectories show that the beam will pass through the plasma about 1.0…1.5 m, which can lead to its significant attenuation. HIBP operation requires obtaininga high-current long-focus probing beam of Tl+ ions (I = 200…400 ΞΌA, f = 4…6 m, d ≀ 10 mm). A high voltage (300 keV) test-benchto test such beams is eing created now. Numerical modeling shows the possibility of a beam formation with a current of 300 ΞΌA and diameter 12 mm at 6 m from the ion emitter.Π—Π°Ρ€Π°Π· Π² НДЦ Β«ΠšΡƒΡ€Ρ‡Π°Ρ‚ΠΎΠ²ΡΡŒΠΊΠΈΠΉ інститут» Π²Π΅Π΄Π΅Ρ‚ΡŒΡΡ Π±ΡƒΠ΄Ρ–Π²Π½ΠΈΡ†Ρ‚Π²ΠΎ Ρ‚ΠΎΠΊΠ°ΠΌΠ°ΠΊΠ° Π”-ΠΎΠ±Ρ€Π°Π·Π½ΠΎΠ³ΠΎ ΠΏΠ΅Ρ€Π΅Ρ€Ρ–Π·Ρƒ Π’-15ΠœΠ”. Зондування ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² (Π—ΠŸΠ’Π†) Ρ” ваТливою Ρ‡Π°ΡΡ‚ΠΈΠ½ΠΎΡŽ діагностичного комплСксу Π’-15ΠœΠ”. Π ΠΎΠ·Ρ€Π°Ρ…ΡƒΠ½ΠΊΠΈ Ρ‚Ρ€Π°Ρ”ΠΊΡ‚ΠΎΡ€Ρ–ΠΉ Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² ΠΏΠΎΠΊΠ°Π·ΡƒΡŽΡ‚ΡŒ, Ρ‰ΠΎ ΠΏΡƒΡ‡ΠΎΠΊ Π±ΡƒΠ΄Π΅ ΠΏΡ€ΠΎΡ…ΠΎΠ΄ΠΈΡ‚ΠΈ Ρƒ ΠΏΠ»Π°Π·ΠΌΡ– ΡˆΠ»ΡΡ… довТиною 1,0…1,5 ΠΌ, Ρ‰ΠΎ ΠΌΠΎΠΆΠ΅ ΠΏΡ€ΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚ΠΈ Π΄ΠΎ Π·Π½Π°Ρ‡Π½ΠΎΠ³ΠΎ ΠΉΠΎΠ³ΠΎ ослаблСння. Для забСзпСчСння моТливості Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Π½ΡŒ ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€Ρ–Π² ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΠΎΡ‚Ρ€Ρ–Π±Π½ΠΎ ΠΎΡ‚Ρ€ΠΈΠΌΠ°Ρ‚ΠΈ ΡΠΈΠ»ΡŒΠ½ΠΎΡΡ‚Ρ€ΡƒΠΌΠΎΠ²ΠΈΡ… довгофокусних Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΈΡ… ΠΏΡƒΡ‡ΠΊΡ–Π² Tl+ (I = 200…400 мкА, f = 4…6 ΠΌ, d ≀ 10 ΠΌΠΌ). На Π΄Π°Π½ΠΈΠΉ час Ρƒ ΠšΡƒΡ€Ρ‡Π°Ρ‚ΠΎΠ²ΡΡŒΠΊΠΎΠΌΡƒ інституті ΡΡ‚Π²ΠΎΡ€ΡŽΡ”Ρ‚ΡŒΡΡ діагностичний стСнд для Π²ΠΈΡ€Ρ–ΡˆΠ΅Π½Π½Ρ Ρ†Ρ–Ρ”Ρ— Π·Π°Π΄Π°Ρ‡Ρ–. На Ρ†ΡŒΠΎΠΌΡƒ стСнді Π±ΡƒΠ΄ΡƒΡ‚ΡŒ проводитися СкспСримСнти ΠΏΠΎ Ρ„ΠΎΠΊΡƒΡΡƒΠ²Π°Π½Π½ΡŽ Ρ–ΠΎΠ½Π½ΠΈΡ… ΠΏΡƒΡ‡ΠΊΡ–Π² Π· Π΅Π½Π΅Ρ€Π³Ρ–Ρ”ΡŽ Π΄ΠΎ 300 ΠΊΠ΅Π’, Π° Ρ‚Π°ΠΊΠΎΠΆ вивчатися властивості Ρ‚Π΅Ρ€ΠΌΠΎΡ–ΠΎΠ½Π½ΠΈΡ… Π΅ΠΌΡ–Ρ‚Π΅Ρ€Ρ–Π² Ρ– час Ρ—Ρ… Тиття. Π ΠΎΠ·Ρ€Π°Ρ…ΡƒΠ½ΠΊΠΈ Ρ€ΡƒΡ…Ρƒ Ρ–ΠΎΠ½Ρ–Π² Π² Ρ–Π½ΠΆΠ΅ΠΊΡ‚ΠΎΡ€Ρ– ΠΏΠΎΠΊΠ°Π·ΡƒΡŽΡ‚ΡŒ ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ створСння ΠΏΡƒΡ‡ΠΊΠ° струмом 300 мкА, Π΄Ρ–Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠΌ 12 ΠΌΠΌ Π½Π° відстані 6 ΠΌ Π²Ρ–Π΄ Ρ–ΠΎΠ½Π½ΠΎΠ³ΠΎ Π΅ΠΌΡ–Ρ‚Π΅Ρ€Π°.Π’ НИЦ Β«ΠšΡƒΡ€Ρ‡Π°Ρ‚ΠΎΠ²ΡΠΊΠΈΠΉ институт» вСдСтся ΡΡ‚Ρ€ΠΎΠΈΡ‚Π΅Π»ΡŒΡΡ‚Π²ΠΎ Ρ‚ΠΎΠΊΠ°ΠΌΠ°ΠΊΠ° Π”-ΠΎΠ±Ρ€Π°Π·Π½ΠΎΠ³ΠΎ сСчСния Π’-15ΠœΠ”. Π—ΠΎΠ½Π΄ΠΈΡ€ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² (Π—ΠŸΠ’Π˜) являСтся Π²Π°ΠΆΠ½ΠΎΠΉ Ρ‡Π°ΡΡ‚ΡŒΡŽ Π΅Π³ΠΎ диагностичСского комплСкса. РасчСты Ρ‚Ρ€Π°Π΅ΠΊΡ‚ΠΎΡ€ΠΈΠΉ Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰ΠΈΡ… ΠΈΠΎΠ½ΠΎΠ² ΠΏΠΎΠΊΠ°Π·Ρ‹Π²Π°ΡŽΡ‚, Ρ‡Ρ‚ΠΎ ΠΏΡƒΡ‡ΠΎΠΊ Π±ΡƒΠ΄Π΅Ρ‚ ΠΏΡ€ΠΎΡ…ΠΎΠ΄ΠΈΡ‚ΡŒ ΠΏΠΎ ΠΏΠ»Π°Π·ΠΌΠ΅ ΠΏΡƒΡ‚ΡŒ Π΄Π»ΠΈΠ½ΠΎΠΉ 1,0…1,5 ΠΌ, Ρ‡Ρ‚ΠΎ ΠΌΠΎΠΆΠ΅Ρ‚ ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ΡŒ ΠΊ Π·Π½Π°Ρ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΌΡƒ Π΅Π³ΠΎ Π·Π°Ρ‚ΡƒΡ…Π°Π½ΠΈΡŽ. Π’ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ измСрСния ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠ² ΠΏΠ»Π°Π·ΠΌΡ‹ Ρ‚Ρ€Π΅Π±ΡƒΠ΅Ρ‚ получСния ΡΠΈΠ»ΡŒΠ½ΠΎΡ‚ΠΎΡ‡Π½Ρ‹Ρ… длиннофокусных Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰ΠΈΡ… ΠΏΡƒΡ‡ΠΊΠΎΠ² ΠΈΠΎΠ½ΠΎΠ² Tl+ (I = 200…400 мкА, f = 4…6 ΠΌ, d ≀ 10 ΠΌΠΌ). ВСстовый стСнд для этой Π·Π°Π΄Π°Ρ‡ΠΈ сСйчас создаСтся. На этом стСндС Π±ΡƒΠ΄ΡƒΡ‚ ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚ΡŒΡΡ экспСримСнты ΠΏΠΎ фокусировкС ΠΈΠΎΠ½Π½Ρ‹Ρ… ΠΏΡƒΡ‡ΠΊΠΎΠ² с энСргиСй Π΄ΠΎ 300 кэВ, Π° Ρ‚Π°ΠΊΠΆΠ΅ ΠΈΠ·ΡƒΡ‡Π°Ρ‚ΡŒΡΡ свойства Ρ‚Π΅Ρ€ΠΌΠΎΠΈΠΎΠ½Π½Ρ‹Ρ… эмиттСров ΠΈ врСмя ΠΈΡ… ΠΆΠΈΠ·Π½ΠΈ. РасчСты двиТСния заряТСнных частиц Π² ионнооптичСской систСмС ΠΈΠ½ΠΆΠ΅ΠΊΡ‚ΠΎΡ€Π° ΠΏΠΎΠΊΠ°Π·Ρ‹Π²Π°ΡŽΡ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ создания ΠΏΡƒΡ‡ΠΊΠ° Ρ‚ΠΎΠΊΠΎΠΌ 300 мкА, Π΄ΠΈΠ°ΠΌΠ΅Ρ‚Ρ€ΠΎΠΌ 12 ΠΌΠΌ Π½Π° расстоянии 6 ΠΌ ΠΎΡ‚ ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ эмиттСра

    The study of the radial location of quasi-coherent modes by heavy ion beam probe in the TJ-II stellarator

    No full text
    Recent experiments in low magnetic shear flexible heliac TJ-II have shown that steady frequency and chirping AlfvΓ©n Eigenmodes take place with 100 kHz< fAE <300 kHz at both pure NBI and combined ECR and NBI heated plasmas with low line-averaged density ne = (0.3…1.5)Γ—10¹⁹ m⁻³ at Low Field Side (LFS) and High Field Side (HFS) of the plasma column. Furthermore, several types of low-frequency modes with f < 30 kHz, such as suprathermal electrostatic modes, tearing-like modes, quasicoherent modes with long-range potential correlations, were also observed. Power spectra for electrostatic and electromagnetic oscillations for all types of modes are presented along with their spatial location detected by dual Heavy Ion Beam Probe (HIBP).ЕкспСримСнти Π½Π° стСлараторі TJ-II ΠΏΠΎΠΊΠ°Π·ΡƒΡŽΡ‚ΡŒ, Ρ‰ΠΎ Π°Π»ΡŒΡ„Π²Π΅Π½ΠΎΠ²ΡΡŒΠΊΡ– ΠΌΠΎΠ΄ΠΈ Ρƒ частотному Π΄Ρ–Π°ΠΏΠ°Π·ΠΎΠ½Ρ– 100 ΠΊΠ“Ρ†< fAE <300 ΠΊΠ“Ρ† Π·Π±ΡƒΠ΄ΠΆΡƒΡŽΡ‚ΡŒΡΡ Π² Ρ€Π΅ΠΆΠΈΠΌΠ°Ρ… Π· Ρ–Π½ΠΆΠ΅ΠΊΡ†Ρ–Ρ”ΡŽ ΠΏΡƒΡ‡ΠΊΠ° Π½Π΅ΠΉΡ‚Ρ€Π°Π»ΡŒΠ½ΠΈΡ… Π°Ρ‚ΠΎΠΌΡ–Π², Π° Ρ‚Π°ΠΊΠΎΠΆ Π² Ρ€Π΅ΠΆΠΈΠΌΠ°Ρ… Π· ΠΊΠΎΠΌΠ±Ρ–Π½ΠΎΠ²Π°Π½ΠΈΠΌ Π•Π¦Π -нагріванням Ρ– Π½Π΅ΠΉΡ‚Ρ€Π°Π»ΡŒΠ½ΠΎΡŽ Ρ–Π½ΠΆΠ΅ΠΊΡ†Ρ–Ρ”ΡŽ ΠΏΡ€ΠΈ ΡΠ΅Ρ€Π΅Π΄Π½ΡŒΠΎΡ…ΠΎΡ€Π΄ΠΎΠ²Ρ–ΠΉ густині Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Ρ–Π² ne = (0,3 … 1,5)Γ—10¹⁹ м⁻³. Моди Π·Π±ΡƒΠ΄ΠΆΡƒΡŽΡ‚ΡŒΡΡ як Π½Π° стороні слабкого, Ρ‚Π°ΠΊ Ρ– Π½Π° стороні сильного поля. ΠšΡ€Ρ–ΠΌ Ρ‚ΠΎΠ³ΠΎ, Ρƒ ΠΏΠ»Π°Π·ΠΌΡ– TJ-II ΡΠΏΠΎΡΡ‚Π΅Ρ€Ρ–Π³Π°ΡŽΡ‚ΡŒΡΡ ΠΌΠΎΠ΄ΠΈ Π· частотами f <30 ΠΊΠ“Ρ†, Π° самС ΠΌΠΎΠ΄ΠΈ, Ρ‰ΠΎ Π·Π±ΡƒΠ΄ΠΆΡƒΡŽΡ‚ΡŒΡΡ швидкими Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Π°ΠΌΠΈ, Ρ‚Ρ–Ρ€Ρ–Π½Π³-ΠΏΠΎΠ΄Ρ–Π±Π½Ρ– ΠΌΠΎΠ΄ΠΈ, Π° Ρ‚Π°ΠΊΠΎΠΆ ΠΌΠΎΠ΄ΠΈ, Ρ‰ΠΎ Ρ…Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€ΠΈΠ·ΡƒΡŽΡ‚ΡŒΡΡ Π΄Π°Π»Π΅ΠΊΠΈΠΌΠΈ корСляціями Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΈΡ‡Π½ΠΎΠ³ΠΎ ΠΏΠΎΡ‚Π΅Π½Ρ†Ρ–Π°Π»Ρƒ. ДСякі ΠΌΠΎΠ΄ΠΈ ΠΌΠ°ΡŽΡ‚ΡŒ Ρ‚Ρ–Π»ΡŒΠΊΠΈ СлСктростатичну ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Ρƒ коливань, Ρ–Π½ΡˆΡ– Ρ‚Π°ΠΊΠΎΠΆ Π²ΠΈΠ΄Π½ΠΎ Π½Π° спСктрах коливань густини Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Ρ–Π² Ρ– ΠΏΠΎΠ»ΠΎΡ—Π΄Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΎΠ³ΠΎ поля. Π£ Ρ€Π°ΠΌΠΊΠ°Ρ… Π΄Π°Π½ΠΎΡ— Ρ€ΠΎΠ±ΠΎΡ‚ΠΈ Π±ΡƒΠ»Π° Π²ΠΈΠ·Π½Π°Ρ‡Π΅Π½Π° Ρ€Π°Π΄Ρ–Π°Π»ΡŒΠ½Π° локалізація ΠΊΠΎΠΆΠ½ΠΎΠ³ΠΎ Ρ‚ΠΈΠΏΡƒ Π·Π³Π°Π΄Π°Π½ΠΈΡ… ΠΊΠ²Π°Π·Ρ–ΠΊΠΎΠ³Π΅Ρ€Π΅Π½Ρ‚Π½ΠΈΡ… ΠΌΠΎΠ΄. Для Ρ†ΡŒΠΎΠ³ΠΎ використовувалися Π΄Π²Π° діагностичних комплСкси Π½Π° ΠΏΡƒΡ‡ΠΊΠ°Ρ… Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π², ΠΌΠ°Π³Π½Ρ–Ρ‚Π½Ρ– Π·ΠΎΠ½Π΄ΠΈ Ρ– Π±ΠΎΠ»ΠΎΠΌΠ΅Ρ‚Ρ€ΠΈ (AXUV-Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€ΠΈ).ЭкспСримСнты Π½Π° стСллараторС TJ-II ΠΏΠΎΠΊΠ°Π·Ρ‹Π²Π°ΡŽΡ‚, Ρ‡Ρ‚ΠΎ Π°Π»ΡŒΡ„Π²Π΅Π½ΠΎΠ²ΡΠΊΠΈΠ΅ ΠΌΠΎΠ΄Ρ‹ Π² частотном Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ 100 ΠΊΠ“Ρ†< fAE <300 ΠΊΠ“Ρ† Π²ΠΎΠ·Π±ΡƒΠΆΠ΄Π°ΡŽΡ‚ΡΡ Π² Ρ€Π΅ΠΆΠΈΠΌΠ°Ρ… с ΠΈΠ½ΠΆΠ΅ΠΊΡ†ΠΈΠ΅ΠΉ ΠΏΡƒΡ‡ΠΊΠ° Π½Π΅ΠΉΡ‚Ρ€Π°Π»ΡŒΠ½Ρ‹Ρ… Π°Ρ‚ΠΎΠΌΠΎΠ², Π° Ρ‚Π°ΠΊΠΆΠ΅ Π² Ρ€Π΅ΠΆΠΈΠΌΠ°Ρ… с ΠΊΠΎΠΌΠ±ΠΈΠ½ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹ΠΌ Π­Π¦Π -Π½Π°Π³Ρ€Π΅Π²ΠΎΠΌ ΠΈ Π½Π΅ΠΉΡ‚Ρ€Π°Π»ΡŒΠ½ΠΎΠΉ ΠΈΠ½ΠΆΠ΅ΠΊΡ†ΠΈΠ΅ΠΉ ΠΏΡ€ΠΈ срСднСхордовой плотности элСктронов ne = (0,3…1,5)Γ—10¹⁹ м⁻³. ΠœΠΎΠ΄Ρ‹ Π²ΠΎΠ·Π±ΡƒΠΆΠ΄Π°ΡŽΡ‚ΡΡ ΠΊΠ°ΠΊ Π½Π° сторонС слабого, Ρ‚Π°ΠΊ ΠΈ Π½Π° сторонС сильного поля. ΠšΡ€ΠΎΠΌΠ΅ Ρ‚ΠΎΠ³ΠΎ, Π² ΠΏΠ»Π°Π·ΠΌΠ΅ TJ-II Π½Π°Π±Π»ΡŽΠ΄Π°ΡŽΡ‚ΡΡ ΠΌΠΎΠ΄Ρ‹ с частотами f < 30 ΠΊΠ“Ρ†, Π° ΠΈΠΌΠ΅Π½Π½ΠΎ ΠΌΠΎΠ΄Ρ‹, Π²ΠΎΠ·Π±ΡƒΠΆΠ΄Π°Π΅ΠΌΡ‹Π΅ быстрыми элСктронами, Ρ‚ΠΈΡ€ΠΈΠ½Π³-ΠΏΠΎΠ΄ΠΎΠ±Π½Ρ‹Π΅ ΠΌΠΎΠ΄Ρ‹, Π° Ρ‚Π°ΠΊΠΆΠ΅ ΠΌΠΎΠ΄Ρ‹, Ρ…Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€ΠΈΠ·ΡƒΡŽΡ‰ΠΈΠ΅ΡΡ дальними коррСляциями элСктричСского ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»Π°. НСкоторыС ΠΌΠΎΠ΄Ρ‹ ΠΈΠΌΠ΅ΡŽΡ‚ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ ΡΠ»Π΅ΠΊΡ‚Ρ€ΠΎΡΡ‚Π°Ρ‚ΠΈΡ‡Π΅ΡΠΊΡƒΡŽ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Ρƒ ΠΊΠΎΠ»Π΅Π±Π°Π½ΠΈΠΉ, Π΄Ρ€ΡƒΠ³ΠΈΠ΅ Ρ‚Π°ΠΊΠΆΠ΅ Π²ΠΈΠ΄Π½Ρ‹ Π½Π° спСктрах ΠΊΠΎΠ»Π΅Π±Π°Π½ΠΈΠΉ плотности элСктронов ΠΈ полоидального ΠΌΠ°Π³Π½ΠΈΡ‚Π½ΠΎΠ³ΠΎ поля. Π’ Ρ€Π°ΠΌΠΊΠ°Ρ… Π΄Π°Π½Π½ΠΎΠΉ Ρ€Π°Π±ΠΎΡ‚Ρ‹ Π±Ρ‹Π»Π° ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π° Ρ€Π°Π΄ΠΈΠ°Π»ΡŒΠ½Π°Ρ локализация ΠΊΠ°ΠΆΠ΄ΠΎΠ³ΠΎ Ρ‚ΠΈΠΏΠ° упомянутых ΠΊΠ²Π°Π·ΠΈΠΊΠΎΠ³Π΅Ρ€Π΅Π½Ρ‚Π½Ρ‹Ρ… ΠΌΠΎΠ΄. Для этого использовалось Π΄Π²Π° диагностичСских комплСкса Π½Π° ΠΏΡƒΡ‡ΠΊΠ°Ρ… тяТСлых ΠΈΠΎΠ½ΠΎΠ², ΠΌΠ°Π³Π½ΠΈΡ‚Π½Ρ‹Π΅ Π·ΠΎΠ½Π΄Ρ‹ ΠΈ Π±ΠΎΠ»ΠΎΠΌΠ΅Ρ‚Ρ€Ρ‹ (AXUV-Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Ρ‹)

    High-intensity cesium ion beams for HIBP diagnostics

    Get PDF
    The goal of the research is to expand the capabilities of the heavy ion beam probing (HIBP) diagnostic. HIBP is a unique diagnostic, capable to measure plasma potential, density and their fluctuations, as well as the poloidal magnetic field fluctuations in the core and edge plasmas. The sensitivity of the diagnostic is determined by the level of the output signal related to the instrumental noise. The level of the probing beam current should be as high as possible, especially for measurements at the periphery with low output signal due to low plasma density, and in the core, where the beam is attenuated due to the high plasma density. Optimization experiments have shown the possibility of ion beam forming in the current range from 40 to 800 ΞΌA.ΠœΠ΅Ρ‚Π° дослідТСння – Ρ€ΠΎΠ·ΡˆΠΈΡ€ΠΈΡ‚ΠΈ моТливості діагностики Π·Π° допомогою зондування ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² (Π—ΠŸΠŸΠ’Π†). Π—ΠŸΠŸΠ’Π† – Ρ†Π΅ ΡƒΠ½Ρ–ΠΊΠ°Π»ΡŒΠ½Π° діагностика, Π·Π΄Π°Ρ‚Π½Π° Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Ρ‚ΠΈ ΠΏΠΎΡ‚Π΅Π½Ρ†Ρ–Π°Π», густину ΠΏΠ»Π°Π·ΠΌΠΈ Ρ– Ρ—Ρ… Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†Ρ–Ρ—, Π° Ρ‚Π°ΠΊΠΎΠΆ Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†Ρ–Ρ— ΠΏΠΎΠ»ΠΎΡ–Π΄Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΎΠ³ΠΎ поля Π² Ρ†Π΅Π½Ρ‚Ρ€Ρ– Ρ‚Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€Ρ–Ρ— ΠΏΠ»Π°Π·ΠΌΠΈ. Π§ΡƒΡ‚Π»ΠΈΠ²Ρ–ΡΡ‚ΡŒ діагностики Π²ΠΈΠ·Π½Π°Ρ‡Π°Ρ”Ρ‚ΡŒΡΡ Ρ€Ρ–Π²Π½Π΅ΠΌ Π²ΠΈΡ…Ρ–Π΄Π½ΠΎΠ³ΠΎ сигналу, Ρ‰ΠΎΠ΄ΠΎ Ρ–Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡˆΡƒΠΌΡƒ. Π Ρ–Π²Π΅Π½ΡŒ струму Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° ΠΏΠΎΠ²ΠΈΠ½Π΅Π½ Π±ΡƒΡ‚ΠΈ якомога Π±Ρ–Π»ΡŒΡˆ високим, особливо для Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Π½ΡŒ Π½Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€Ρ–Ρ— Π· низьким Π²ΠΈΡ…Ρ–Π΄Π½ΠΈΠΌ сигналом Ρ‡Π΅Ρ€Π΅Π· Π½ΠΈΠ·ΡŒΠΊΡƒ густину ΠΏΠ»Π°Π·ΠΌΠΈ, Π° Ρ‚Π°ΠΊΠΎΠΆ Ρƒ Ρ†Π΅Π½Ρ‚Ρ€Ρ–, Π΄Π΅ ΠΏΡƒΡ‡ΠΎΠΊ ΠΏΠΎΡΠ»Π°Π±Π»ΡŽΡ”Ρ‚ΡŒΡΡ Ρ‡Π΅Ρ€Π΅Π· високу густину ΠΏΠ»Π°Π·ΠΌΠΈ. ЕкспСримСнти Π· ΠΎΠΏΡ‚ΠΈΠΌΡ–Π·Π°Ρ†Ρ–Ρ— ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ формування Ρ–ΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π² Π΄Ρ–Π°ΠΏΠ°Π·ΠΎΠ½Ρ– струму 40…800 мкА.ЦСль исслСдования – Ρ€Π°ΡΡˆΠΈΡ€ΠΈΡ‚ΡŒ возмоТности диагностики с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ зондирования ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² (Π—ΠŸΠŸΠ’Π˜). Π—ΠŸΠŸΠ’Π˜ – это ΡƒΠ½ΠΈΠΊΠ°Π»ΡŒΠ½Π°Ρ диагностика, способная ΠΈΠ·ΠΌΠ΅Ρ€ΡΡ‚ΡŒ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π», ΠΏΠ»ΠΎΡ‚Π½ΠΎΡΡ‚ΡŒ ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΈ ΠΈΡ… Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†ΠΈΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†ΠΈΠΈ полоидального ΠΌΠ°Π³Π½ΠΈΡ‚Π½ΠΎΠ³ΠΎ поля Π² Ρ†Π΅Π½Ρ‚Ρ€Π΅ ΠΈ ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€ΠΈΠΈ ΠΏΠ»Π°Π·ΠΌΡ‹. Π§ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ диагностики опрСдСляСтся ΡƒΡ€ΠΎΠ²Π½Π΅ΠΌ Π²Ρ‹Ρ…ΠΎΠ΄Π½ΠΎΠ³ΠΎ сигнала ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ ΠΈΠ½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡˆΡƒΠΌΠ°. Π£Ρ€ΠΎΠ²Π΅Π½ΡŒ Ρ‚ΠΎΠΊΠ° Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰Π΅Π³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π΄ΠΎΠ»ΠΆΠ΅Π½ Π±Ρ‹Ρ‚ΡŒ ΠΊΠ°ΠΊ ΠΌΠΎΠΆΠ½ΠΎ Π±ΠΎΠ»Π΅Π΅ высоким, особСнно для ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ Π½Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€ΠΈΠΈ с Π½ΠΈΠ·ΠΊΠΈΠΌ Π²Ρ‹Ρ…ΠΎΠ΄Π½Ρ‹ΠΌ сигналом ΠΈΠ·-Π·Π° Π½ΠΈΠ·ΠΊΠΎΠΉ плотности ΠΏΠ»Π°Π·ΠΌΡ‹, Π° Ρ‚Π°ΠΊΠΆΠ΅ Π² Ρ†Π΅Π½Ρ‚Ρ€Π΅, Π³Π΄Π΅ ΠΏΡƒΡ‡ΠΎΠΊ ослабляСтся ΠΈΠ·-Π·Π° высокой плотности ΠΏΠ»Π°Π·ΠΌΡ‹. ЭкспСримСнты ΠΏΠΎ ΠΎΠΏΡ‚ΠΈΠΌΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ формирования ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Ρ‚ΠΎΠΊΠ° 40…800 мкА