1,450 research outputs found
Components Qualification for a Possible use in the Mu2e Calorimeter Waveform Digitizers
The Mu2e experiment at Fermilab searches for the charged flavor violating
conversion of a muon into an electron in the Coulomb field of a nucleus. The
detector consists of a straw tube tracker and a CSI crystal electromagnetic
calorimeter, both housed in a superconducting solenoid. Both the front-end and
the digital electronics, located inside the cryostat, will be operated in
vacuum under a 1 T magnetic field, having to sustain the high flux of neutrons
and ionizing particles coming from the muons stopping target. These harsh
experimental conditions make the design of the calorimeter waveform digitizer
quite challenging. All the selected commercial devices must be tested
individually and qualified for radiation hardness and operation in high
magnetic field. At the moment the expected particles flux and spectra at the
digitizers location are not completely simulated and we are using initial rough
estimates to select the components for the first prototype. We are gaining
experience in the qualification procedures using the selected components but
the choice will be frozen only when dose and neutron flux simulations will be
completed. The experimental results of the first qualification campaign are
presented.Comment: TWEPP 2016 - Topical Workshop on Electronics for Particle Physics,
26-30 September 2016, Karlsruhe Institute of Technology (KIT
Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers
The Mu2e electromagnetic calorimeter has to provide precise information on
energy, time and position for 100 MeV electrons. It is composed of 1348
un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers
(SiPMs). A modular and custom SiPM layout consisting of a 32 array of
66 mm UV-extended monolithic SiPMs has been developed to fulfill
the Mu2e calorimeter requirements and a pre-production of 150 prototypes has
been procured by three international firms (Hamamatsu, SensL and Advansid). A
detailed quality assurance process has been carried out on this first batch of
photosensors: the breakdown voltage, the gain, the quenching time, the dark
current and the Photon Detection Efficiency (PDE) have been determined for each
monolithic cell of each SiPMs array. One sample for each vendor has been
exposed to a neutron fluency up to 8.5~~10 1 MeV (Si) eq.
n/cm and a linear increase of the dark current up to tens of mA has been
observed. Others 5 samples for each vendor have undergone an accelerated aging
in order to verify a Mean Time To Failure (MTTF) higher than 10
hours.Comment: NDIP 2017 - New Developments In Photodetection, 3-7 July 2017, Tours
(France
Energy and time resolution for a LYSO matrix prototype of the Mu2e experiment
We have measured the performances of a LYSO crystal matrix prototype tested
with electron and photon beams in the energy range 60450 MeV. This study has
been carried out to determine the achievable energy and time resolutions for
the calorimeter of the Mu2e experiment.Comment: 2 pages, 3 figures, 13th Pisa Meeting on Advanced Detector
Design, status and perspective of the Mu2e crystal calorimeter
The Mu2e experiment at Fermilab will search for the charged lepton flavor
violating process of neutrino-less coherent conversion in the field
of an aluminum nucleus. Mu2e will reach a single event sensitivity of about
that corresponds to four orders of magnitude improvements
with respect to the current best limit. The detector system consists of a straw
tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon
Photomultipliers. The calorimeter was designed to be operable in a harsh
environment where about 10 krad/year will be delivered in the hottest region
and work in presence of 1 T magnetic field. The calorimeter role is to perform
/e separation to suppress cosmic muons mimiking the signal, while
providing a high level trigger and a seeding the track search in the tracker.
In this paper we present the calorimeter design and the latest RD results.Comment: 4 pages, conference proceeding for a presentation held at TIPP'2017.
To be published on Springer Proceedings in Physic
The impact of digital patient portals on health outcomes, system efficiency, and patient attitudes: Updated systematic literature review
Background: Patient portals are becoming increasingly popular worldwide even though their impact on individual health and health system efficiency is still unclear. Objective: The aim of this systematic review was to summarize evidence on the impact of patient portals on health outcomes and health care efficiency, and to examine user characteristics, attitudes, and satisfaction. Methods: We searched the PubMed and Web of Science databases for articles published from January 1, 2013, to October 31, 2019. Eligible studies were primary studies reporting on the impact of patient portal adoption in relation to health outcomes, health care efficiency, and patient attitudes and satisfaction. We excluded studies where portals were not accessible for patients and pilot studies, with the exception of articles evaluating patient attitudes. Results: Overall, 3456 records were screened, and 47 articles were included. Among them, 11 studies addressed health outcomes reporting positive results, such as better monitoring of health status, improved patient-doctor interaction, and improved quality of care. Fifteen studies evaluated the impact of digital patient portals on the utilization of health services with mixed results. Patient characteristics were described in 32 studies, and it was reported that the utilization rate usually increases with age and female gender. Finally, 30 studies described attitudes and defined the main barriers (concerns about privacy and data security, and lack of time) and facilitators (access to clinical data and laboratory results) to the use of a portal. Conclusions: Evidence regarding health outcomes is generally favorable, and patient portals have the potential to enhance the doctor-patient relationship, improve health status awareness, and increase adherence to therapy. It is still unclear whether the use of patient portals improves health service utilization and efficiency
Quality Assurance on a custom SiPMs array for the Mu2e experiment
The Mu2e experiment at Fermilab will search for the coherent
conversion on aluminum atoms. The detector system consists of a straw tube
tracker and a crystal calorimeter. A pre-production of 150 Silicon
Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed
quality assur- ance has been carried out on each SiPM for the determination of
its own operation voltage, gain, dark current and PDE. The measurement of the
mean-time-to-failure for a small random sample of the pro-production group has
been also completed as well as the determination of the dark current increase
as a function of the ioninizing and non-ioninizing dose.Comment: 4 pages, 10 figures, conference proceeding for NSS-MIC 201
The Mu2e undoped CsI crystal calorimeter
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor
Violating conversion of a muon to an electron in an atomic field. The Mu2e
detector is composed of a tracker, an electromagnetic calorimeter and an
external system, surrounding the solenoid, to veto cosmic rays. The calorimeter
plays an important role to provide: a) excellent particle identification
capabilities; b) a fast trigger filter; c) an easier tracker track
reconstruction. Two disks, located downstream of the tracker, contain 674 pure
CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs.
The choice of the crystals and SiPMs has been finalized after a thorough test
campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM
arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in
Frascati. Although the readout electronics were not the final, results show
that the current design is able to meet the timing and energy resolution
required by the Mu2e experiment.Comment: 6 pages, 8 figures, proceedings of the "Calorimetry for the high
energy frontier (CHEF17)" conference, 2-6 October 2017, Lyon, Franc
- …