40 research outputs found

    Influence of Electropulsing Treatments on Mechanical Properties of UNS S32750 Duplex Stainless Steel

    Get PDF
    Prestrained at 5% and 15% duplex stainless steel UNS S32750 specimens have been subjected to electropulsing treatments with current density of 100 A/mm2 and 200 A/mm2 and 100 and 500 pulses for each current density value. Corrosion tests, X-ray diffraction, microhardness and residual stresses were collected before and after the electropulsing treatments. Tensile tests were performed after the electropulsing treatments in order to compare the mechanical response to reference tensile tests performed before pulsing treatments. Increase in fracture strain was observed after pulsing treatment in comparison to the reference tensile tests. A decrease in microhardness was also observed after electropulsing treatments for both degrees of prestrain. Electropulsing treatment almost eliminates the work-hardened state in the 5% prestrained specimens while partially recovered the 15% prestrained material increasing both uniform and fracture strain. Bulk temperature of the samples remained the same for all treatments duration. The effect are to be addressed to a combined effect of increase in atomic flux due to the electrical current and local joule heating in correspondence of crystal defects. Electropulsing treatment applied to metallic alloys is a promising technique to reduce the work hardening state without the need of annealing treatments in a dedicated furnace

    Pragmatic electrocardiogram tracings in non-ischaemic dilated cardiomyopathy: diagnostic and prognostic role

    Get PDF
    Dilated cardiomyopathy (DCM) is a primitive heart muscle disease characterized by a great heterogeneous aetiology and prognostic outcome. Dilated cardiomyopathy is an umbrella term encompassing different aetiologies that might require specific treatments. It principally affects young and male adults, with high-risk arrhythmic competitive risk. Unfortunately, the prevention of major ventricular arrhythmic events remains a clinical challenge. In the era of advanced multimodality imaging and widely available genetic testing, electrocardiogram (ECG) continues to represent a reliable diagnostic tool, for specific work up of every single patient. However, approaching DCM patients, only a cardiomyopathy-oriented reading makes the role of ECG central in the management of DCM, both for diagnosis, prognosis, and therapeutic management. In this paper, we present four ECGs of four different DCM patients, in order to guide a cardiomyopathy-oriented ECG reading, emphasizing its impact in an early, cost-effective, and personalized diagnostic and prognostic work up in this specific setting

    Electrocardiographic abnormalities in patients with cardiomyopathies

    Get PDF
    Abnormalities in impulse generation and transmission are among the first signs of cardiac remodeling in cardiomyopathies. Accordingly, 12-lead electrocardiogram (ECG) of patients with cardiomyopathies may show multiple abnormalities. Some findings are suggestive of specific disorders, such as the discrepancy between QRS voltages and left ventricular (LV) mass for cardiac amyloidosis or the inverted T waves in the right precordial leads for arrhythmogenic cardiomyopathy. Other findings are less sensitive and/or specific, but may orient toward a specific diagnosis in a patient with a specific phenotype, such as an increased LV wall thickness or a dilated LV. A “cardiomyopathy-oriented” mindset to ECG reading is important to detect the possible signs of an underlying cardiomyopathy and to interpret correctly the meaning of these alterations, which differs in patients with cardiomyopathies or other conditions

    Continuous Monitoring of Cerebral Autoregulation in Children Supported by Extracorporeal Membrane Oxygenation: A Pilot Study.

    Get PDF
    OBJECTIVE: Cerebral autoregulation (CA) impairment may pose a risk factor for neurological complications among children supported by extracorporeal membrane oxygenation (ECMO). Our first objective was to investigate the feasibility of CA continuous monitoring during ECMO treatment and to describe its evolution over time. The second objective was to analyze the association between CA impairment and neurological outcome. DESIGN: Observational prospective study. PATIENTS AND SETTING: Twenty-nine children treated with veno-arterial or veno-venous ECMO in the PICU of Nantes University Hospital, France, and the PICU of the IRCCS Giannina Gaslini Institute in Genoa, Italy. MEASUREMENTS: A correlation coefficient between the variations of regional cerebral oxygen saturation and the variations of mean arterial blood pressure (MAP) was calculated as an index of CA (cerebral oxygenation reactivity index, COx). A COx > 0.3 was considered as indicative of autoregulation impairment. COx-MAP plots were investigated allowing determining optimal MAP (MAPopt) and limits of autoregulation: lower (LLA) and upper (ULA). Neurological outcome was assessed by the onset of an acute neurological event (ANE) after ECMO start. RESULTS: We included 29 children (median age 84 days, weight 4.8 kg). MAPopt, LLA, and ULA were detected in 90.8% (84.3-93.3) of monitoring time. Mean COx was significantly higher during day 1 of ECMO compared to day 2 [0.1 (0.02-0.15) vs. 0.01 (- 0.05 to 0.1), p = 0.002]. Twelve children experienced ANE (34.5%). The mean COx and the percentage of time spent with a COx > 0.3 were significantly higher among ANE+ compared to ANE- patients [0.09 (0.01-0.23) vs. 0.04 (- 0.02 to 0.06), p = 0.04 and 33.3% (24.8-62.1) vs. 20.8% (17.3-23.7) p = 0.001]. ANE+ patients spent significantly more time with MAP below LLA [17.2% (6.5-32.9) vs. 5.6% (3.6-9.9), p = 0.02] and above ULA [13% (5.3-38.4) vs. 4.2% (2.7-7.4), p = 0.004], respectively. CONCLUSION: CA assessment is feasible in pediatric ECMO. The first 24 h following ECMO represents the most critical period regarding CA. Impaired autoregulation is significantly more severe among patients who experience ANE

    Effects of eight weeks of aerobic interval training and of isoinertial resistance training on risk factors of cardiometabolic diseases and exercise capacity in healthy elderly subjects

    Get PDF
    We investigated the effect of 8 weeks of high intensity interval training (HIT) and isoinertial resistance training (IRT) on cardiovascular fitness, muscle mass-strength and risk factors of metabolic syndrome in 12 healthy older adults (68 yy \ub1 4). HIT consisted in 7 two-minute repetitions at 80%-90% of V\ucb\u99O2max, 3 times/w. After 4 months of recovery, subjects were treated with IRT, which included 4 sets of 7 maximal, bilateral knee extensions/flexions 3 times/w on a leg-press flywheel ergometer. HIT elicited significant: i) modifications of selected anthropometrical features; ii) improvements of cardiovascular fitness and; iii) decrease of systolic pressure. HIT and IRT induced hypertrophy of the quadriceps muscle, which, however, was paralleled by significant increases in strength only after IRT. Neither HIT nor IRT induced relevant changes in blood lipid profile, with the exception of a decrease of LDL and CHO after IRT. Physiological parameters related with aerobic fitness and selected body composition values predicting cardiovascular risk remained stable during detraining and, after IRT, they were complemented by substantial increase of muscle strength, leading to further improvements of quality of life of the subjects

    ECG come “red flag” e potenziale predittore prognostico (2)

    No full text
    DESCRIZIONE DEL CASO Uomo di 42 anni, non familiarità per cardiopatie né per morte improvvisa, non fattori di rischio cardiovascolare. Ricoverato per primo episodio di scompenso cardiaco in corso di broncopolmonite. All’ecocardiografia: frazione di eiezione ventricolare sinistra 41%, severa dilatazione e disfunzione ventricolare destra (frazione di variazione delle aree: 12%), con estroflessioni acinetiche e insufficienza tricuspidalica severa. DESCRIZIONE DELL’ECG Ritmo sinusale, ingrandimento biatriale con onde P “polmonari” giganti in quasi tutte le derivazioni. Onde Q infero-laterali. Diffusi bassi voltaggi del QRS (sommatoria periferiche: 10 mm; precordiali: 18 mm), onde epsilon in V1-V3. Blocco di branca destra e diffuse alterazioni della ripolarizzazione

    Optic Nerve Sheath Diameter Ultrasound: A Non-Invasive Approach to Evaluate Increased Intracranial Pressure in Critically Ill Pediatric Patients

    No full text
    Early diagnosis of increased intracranial pressure (ICP) is crucial for prompt diagnosis and treatment of intracranial hypertension in critically ill pediatric patients, preventing secondary brain damage and mortality. Although the placement of an external ventricular drain coupled to an external fluid-filled transducer remains the gold standard for continuous ICP monitoring, other non-invasive approaches are constantly being improved and can provide reliable estimates. The use of point-of-care ultrasound (POCUS) for the assessment of ICP has recently become widespread in pediatric emergency and critical care settings, representing a valuable extension of the physical examination. The aim of this manuscript is to review and discuss the basic principles of ultra-sound measurement of the optic nerve sheath diameter (ONSD) and summarize current evidence on its diagnostic value in pediatric patients with ICP. There is increasing evidence that POCUS measurement of the ONSD correlates with ICP, thus appearing as a useful extension of the physical examination in pediatrics, especially in emergency medicine and critical care settings for the initial non-invasive assessment of patients with suspected raised ICP. Its role could be of value even to assess the response to therapy and in the follow-up of patients with diagnosed intracranial hypertension if invasive ICP monitoring is not available. Further studies on more homogeneous and extensive study populations should be performed to establish ONSD reference ranges in the different pediatric ages and to define cut-off values in predicting elevated ICP compared to invasive ICP measurement
    corecore