14 research outputs found

    ARTreat Project: Three-Dimensional Numerical Simulation of Plaque Formation and Development in the Arteries

    Get PDF
    Atherosclerosis is a progressive disease characterized by the accumulation of lipids and fibrous elements in arteries. It is characterized by dysfunction of endothelium and vasculitis, and accumulation of lipid, cholesterol, and cell elements inside blood vessel wall. In this study, a continuum-based approach for plaque formation and development in 3-D is presented. The blood flow is simulated by the 3-D Navier-Stokes equations, together with the continuity equation while low-density lipoprotein (LDL) transport in lumen of the vessel is coupled with Kedem-Katchalsky equations. The inflammatory process was solved using three additional reaction-diffusion partial differential equations. Transport of labeled LDL was fitted with our experiment on the rabbit animal model. Matching with histological data for LDL localization was achieved. Also, 3-D model of the straight artery with initial mild constriction of 30% plaque for formation and development is presented

    Information System for Monitoring and Forecast of Building Heat Consumption

    No full text

    FPGA implementation of fuzzy medical decision support system for disc hernia diagnosis

    No full text
    The aim of this study was to create a decision support system for disc hernia diagnostics based on real measurements of foot force values from sensors and fuzzy logic, as well as to implement the system on Field Programmable Gate Array (FPGA). The results show that the created fuzzy logic system had the 92.8% accuracy for pre-operational diagnosis and very high match between the Matlab and FPGA output (94.2% match for pre-operational condition, and 100% match for the post-operational and after physical therapy conditions). Interestingly enough, our system is also able to detect improvements in patient condition after the surgery and physical therapy. The main benefit of using FPGAs in this study is to create an inexpensive, portable expert system for real time acquisition, processing and providing the objective recommendation for disc hernia diagnosis and tracking the condition improvement

    Acceleration of Image Segmentation Algorithm for (Breast) Mammogram Images Using High-Performance Reconfigurable Dataflow Computers

    No full text
    © 2017 Ivan L. Milankovic et al. Image segmentation is one of the most common procedures in medical imaging applications. It is also a very important task in breast cancer detection. Breast cancer detection procedure based on mammography can be divided into several stages. The first stage is the extraction of the region of interest from a breast image, followed by the identification of suspicious mass regions, their classification, and comparison with the existing image database. It is often the case that already existing image databases have large sets of data whose processing requires a lot of time, and thus the acceleration of each of the processing stages in breast cancer detection is a very important issue. In this paper, the implementation of the already existing algorithm for region-of-interest based image segmentation for mammogram images on High-Performance Reconfigurable Dataflow Computers (HPRDCs) is proposed. As a dataflow engine (DFE) of such HPRDC, Maxeler's acceleration card is used. The experiments for examining the acceleration of that algorithm on the Reconfigurable Dataflow Computers (RDCs) are performed with two types of mammogram images with different resolutions. There were, also, several DFE configurations and each of them gave a different acceleration value of algorithm execution. Those acceleration values are presented and experimental results showed good acceleration

    Syllable-based speech recognition using electromyography and decision set classifier

    No full text
    © 2015 National Taiwan University. During the speech, contractions of muscles in the speech apparatus produce myoelectric signals that can be picked up by electrodes, filtered and analyzed. The problem of extraction of speech information from these signals is significant for patients with damaged speech apparatus, such as laryngectomy patients, who could use speech recognition based on myoelectric signal classification to communicate by means of the synthetic speech. In the most previously conducted research, classification is performed on a ten word vocabulary which resulted in a good classification rate. In this paper, a possibility for myoelectric syllable based speech classification is analyzed on a significantly larger vocabulary with novel decision set based classifier which is simple, easy to adapt, convenient for research and similar to the way humans think. In order to have a high quality of recorded myoelectric signals, analysis of the optimal position of electrodes is performed. Classification is performed by comparison between syllable combination and whole words. Based on classification rate, words can belong to easy, medium or hard to distinguish group. Results based on generated list of best matching combinations show that decision set analysis of myoelectric signals for speech recognition is a promising novel method

    Transient finite element modeling of functional electrical stimulation

    No full text
    Transcutaneous functional electrical stimulation is commonly used for strengthening muscle. However, transient effects during stimulation are not yet well explored. The effect of an amplitude change of the stimulation can be described by static model, but there is no differency for different pulse duration. The aim of this study is to present the finite element (FE) model of a transient electrical stimulation on the forearm. Discrete FE equations were derived by using a standard Galerkin procedure. Different tissue conductive and dielectric properties are fitted using least square method and trial and error analysis from experimental measurement. This study showed that FE modeling of electrical stimulation can give the spatial-temporal distribution of applied current in the forearm. Three different cases were modeled with the same geometry but with different input of the current pulse, in order to fit the tissue properties by using transient FE analysis. All three cases were compared with experimental measurements of intramuscular voltage on one volunteer

    Assessment of Knee Cartilage Stress Distribution and Deformation Using Motion Capture System and Wearable Sensors for Force Ratio Detection

    Get PDF
    Knowledge about the knee cartilage deformation ratio as well as the knee cartilage stress distribution is of particular importance in clinical studies due to the fact that these represent some of the basic indicators of cartilage state and that they also provide information about joint cartilage wear so medical doctors can predict when it is necessary to perform surgery on a patient. In this research, we apply various kinds of sensors such as a system of infrared cameras and reflective markers, three-axis accelerometer, and force plate. The fluorescent marker and accelerometers are placed on the patient’s hip, knee, and ankle, respectively. During a normal walk we are recording the space position of markers, acceleration, and ground reaction force by force plate. Measured data are included in the biomechanical model of the knee joint. Geometry for this model is defined from CT images. This model includes the impact of ground reaction forces, contact force between femur and tibia, patient body weight, ligaments, and muscle forces. The boundary conditions are created for the finite element method in order to noninvasively determine the cartilage stress distribution

    Assessment of knee cartilage stress distribution and deformation using motion capture system and wearable sensors for force ratio detection

    No full text
    © 2015 N. Mijailovic et al. Knowledge about the knee cartilage deformation ratio as well as the knee cartilage stress distribution is of particular importance in clinical studies due to the fact that these represent some of the basic indicators of cartilage state and that they also provide information about joint cartilage wear so medical doctors can predict when it is necessary to perform surgery on a patient. In this research, we apply various kinds of sensors such as a system of infrared cameras and reflective markers, three-axis accelerometer, and force plate. The fluorescent marker and accelerometers are placed on the patient's hip, knee, and ankle, respectively. During a normal walk we are recording the space position of markers, acceleration, and ground reaction force by force plate. Measured data are included in the biomechanical model of the knee joint. Geometry for this model is defined from CT images. This model includes the impact of ground reaction forces, contact force between femur and tibia, patient body weight, ligaments, and muscle forces. The boundary conditions are created for the finite element method in order to noninvasively determine the cartilage stress distribution

    Manufacturing of biodegradable scaffolds to engineer artificial blood vessel

    No full text
    © 2018, University of Kragujevac, Faculty of Science. All rights reserved. Blood vessels diseases such as cardiac infarction with coronary artery occlusion, peripheral arterial disorders, or stroke of carotid or cerebral arteries, are the leading causes of death in the world. One of medical procedures for clinical treatment of vascular diseases is the blood vessels grafting. As the autologous blood vessels, which are the “golden standard” for coronary grafting, are not always suitable for blood vessels grafting, there is a need to develop artificial blood vessels as a vascular prostheses, either from natural and synthetic materials, permanent synthetic or biodegradable scaffolds which would be suitable for vascular grafts. Considering this to be our study goal we made bilayered biodegradable polycaprolactone scaffolds with different properties and evaluated their morphological and biomechanical characteristics

    Electromagnetic field investigation on different cancer cell lines

    No full text
    © 2014 Filipovic et al.; licensee BioMed Central Ltd. Background: There is a strong interest in the investigation of extremely low frequency Electromagnetic Fields (EMF) in the clinic. While evidence about anticancer effects exists, the mechanism explaining this effect is still unknown. Methods: We investigated in vitro, and with computer simulation, the influence of a 50 Hz EMF on three cancer cell lines: breast cancer MDA-MB-231, and colon cancer SW-480 and HCT-116. After 24 h preincubation, cells were exposed to 50 Hz extremely low frequency (ELF) radiofrequency EMF using in vitro exposure systems for 24 and 72 h. A computer reaction-diffusion model with the net rate of cell proliferation and effect of EMF in time was developed. The fitting procedure for estimation of the computer model parameters was implemented. Results: Experimental results clearly showed disintegration of cells treated with a 50 Hz EMF, compared to untreated control cells. A large percentage of treated cells resulted in increased early apoptosis after 24 h and 72 h, compared to the controls. Computer model have shown good comparison with experimental data. Conclusion: Using EMF at specific frequencies may represent a new approach in controlling the growth of cancer cells, while computer modelling could be used to predict such effects and make optimisation for complex experimental design. Further studies are required before testing this approach in humans
    corecore