7 research outputs found

    Polymer-based or polymer-free stents in patients at high bleeding risk

    Get PDF
    Background: polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. Methods: in an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. Results: a total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). Conclusions: among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.)

    Antiplatelet therapy following transcatheter aortic valve implantation

    No full text
    There is limited evidence to support decision making on antiplatelet therapy following transcatheter aortic valve implantation (TAVI). Our aim was to assess the efficacy and safety of aspirin-only (ASA) versus dual antiplatelet therapy (DAPT) following TAVI

    Polymer-Based Versus Polymer-Free Stents in High Bleeding Risk Patients: Final 2-Year Results From Onyx ONE

    No full text
    © 2022 American College of Cardiology FoundationBackground: Resolute Onyx polymer-based zotarolimus-eluting stents (ZES) were noninferior in safety and effectiveness to BioFreedom polymer-free biolimus A9-coated stents (DCS) in high-bleeding-risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) at 1 year. Objectives: This study reports the final 2-year results of the randomized Onyx ONE trial. Methods: The Onyx ONE (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy (DAPT) for High-Bleeding Risk Patients) trial randomly assigned HBR patients to treatment with ZES or DCS. Following 1-month DAPT, event-free patients received SAPT (either aspirin or a P2Y12 inhibitor at physician discretion). The primary safety endpoint, a composite of cardiac death, myocardial infarction, or stent thrombosis at 1 year, was determined at 1 year. Rates of primary and secondary endpoints were calculated after final follow-up at 2 years. Results: A total of 1,003 patients were randomly allocated to ZES and 993 patients to DCS. Follow-up was complete in 980 (97.7%) ZES patients and 962 (96.9%) DCS patients at 2 years. The primary safety endpoint occurred in 208 (21.2%) patients in the ZES group and 199 (20.7%) patients in the DCS group (risk difference: 0.5%; 95% CI: −3.1% to 4.2%; P = 0.78) at 2 years without significant differences in individual components of the composite endpoint. The secondary effectiveness endpoint occurred in 217 (22.1%) patients in the ZES group and 202 (21.0%) patients in the DCS group (risk difference: 1.1%; 95% CI: −2.5% to 4.8%; P = 0.54). Conclusions: Among patients at HBR treated with 1-month DAPT followed by SAPT, the Resolute Onyx polymer-based ZES had similar 2-year outcomes for the primary safety and secondary effectiveness endpoint compared with the BioFreedom polymer-free DCS. (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy [DAPT] for High-Bleeding Risk Patients [Onyx ONE]; NCT03344653)N

    Polymer-Based Versus Polymer-Free Stents in High Bleeding Risk Patients: Final 2-Year Results From Onyx ONE.

    No full text
    BACKGROUND Resolute Onyx polymer-based zotarolimus-eluting stents (ZES) were noninferior in safety and effectiveness to BioFreedom polymer-free biolimus A9-coated stents (DCS) in high-bleeding-risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) at 1 year. OBJECTIVES This study reports the final 2-year results of the randomized Onyx ONE trial. METHODS The Onyx ONE (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy (DAPT) for High-Bleeding Risk Patients) trial randomly assigned HBR patients to treatment with ZES or DCS. Following 1-month DAPT, event-free patients received SAPT (either aspirin or a P2Y12 inhibitor at physician discretion). The primary safety endpoint, a composite of cardiac death, myocardial infarction, or stent thrombosis at 1 year, was determined at 1 year. Rates of primary and secondary endpoints were calculated after final follow-up at 2 years. RESULTS A total of 1,003 patients were randomly allocated to ZES and 993 patients to DCS. Follow-up was complete in 980 (97.7%) ZES patients and 962 (96.9%) DCS patients at 2 years. The primary safety endpoint occurred in 208 (21.2%) patients in the ZES group and 199 (20.7%) patients in the DCS group (risk difference: 0.5%; 95% CI: -3.1% to 4.2%; P = 0.78) at 2 years without significant differences in individual components of the composite endpoint. The secondary effectiveness endpoint occurred in 217 (22.1%) patients in the ZES group and 202 (21.0%) patients in the DCS group (risk difference: 1.1%; 95% CI: -2.5% to 4.8%; P = 0.54). CONCLUSIONS Among patients at HBR treated with 1-month DAPT followed by SAPT, the Resolute Onyx polymer-based ZES had similar 2-year outcomes for the primary safety and secondary effectiveness endpoint compared with the BioFreedom polymer-free DCS. (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy [DAPT] for High-Bleeding Risk Patients [Onyx ONE]; NCT03344653)
    corecore