104 research outputs found

    Multisensory attention training for treatment of tinnitus

    Get PDF
    Spiegel, D. P. et al. Multisensory attention training for treatment of tinnitus. Sci. Rep. 5, 10802; doi: 10.1038/srep10802 (2015).Tinnitus is the conscious perception of sound with no physical sound source. Some models of tinnitus pathophysiology suggest that networks associated with attention, memory, distress and multisensory experience are involved in tinnitus perception. The aim of this study was to evaluate whether a multisensory attention training paradigm which used audio, visual, and somatosensory stimulation would reduce tinnitus. Eighteen participants with predominantly unilateral chronic tinnitus were randomized between two groups receiving 20 daily sessions of either integration (attempting to reduce salience to tinnitus by binding with multisensory stimuli) or attention diversion (multisensory stimuli opposite side to tinnitus) training. The training resulted in small but statistically significant reductions in Tinnitus Functional Index and Tinnitus Severity Numeric Scale scores and improved attentional abilities. No statistically significant improvements in tinnitus were found between the training groups. This study demonstrated that a short period of multisensory attention training reduced unilateral tinnitus, but directing attention toward or away from the tinnitus side did not differentiate this effect.This work was supported by a grant from Links Research and Grants Corporation to G.D.S

    On chirp stimuli and neural synchrony in the suprathreshold auditory brainstem response

    Get PDF
    The chirp-evoked ABR has been regarded as a more synchronous response than the click-evoked ABR, referring to the belief that the chirp stimulates lower-, mid-, and higher-frequency regions of the cochlea simultaneously. In this study a variety of tools were used to analyze the synchronicity of ABRs evoked by chirp- and click-stimuli at 40 dB HL in 32 normal hearing subjects aged 18 to 55 years (mean=24.8 years, SD=7.1 years). Compared to the click-evoked ABRs, the chirp-evoked ABRs showed larger wave V amplitudes, but an absence of earlier waves in the grand averages, larger wave V latency variance, smaller FFT magnitudes at the higher component frequencies, and larger phase variance at the higher component frequencies. These results strongly suggest that the chirp-evoked ABRs exhibited less synchrony than the click-evoked ABRs in this study. It is proposed that the temporal compensation offered by chirp stimuli is sufficient to increase neural recruitment (as measured by wave V amplitude), but that destructive phase interactions still exist along the cochlea partition, particularly in the low frequency portions of the cochlea where more latency jitter is expected. The clinical implications of these findings are discussed. (C) 2010 Acoustical Society of America. [DOI: 10.1121/1.3436527

    An update on retinal prostheses

    Get PDF
    Retinal prostheses are designed to restore a basic sense of sight to people with profound vision loss. They require a relatively intact posterior visual pathway (optic nerve, lateral geniculate nucleus and visual cortex). Retinal implants are options for people with severe stages of retinal degenerative disease such as retinitis pigmentosa and age-related macular degeneration. There have now been three regulatory-approved retinal prostheses. Over five hundred patients have been implanted globally over the past 15 years. Devices generally provide an improved ability to localize high-contrast objects, navigate, and perform basic orientation tasks. Adverse events have included conjunctival erosion, retinal detachment, loss of light perception, and the need for revision surgery, but are rare. There are also specific device risks, including overstimulation (which could cause damage to the retina) or delamination of implanted components, but these are very unlikely. Current challenges include how to improve visual acuity, enlarge the field-of-view, and reduce a complex visual scene to its most salient components through image processing. This review encompasses the work of over 40 individual research groups who have built devices, developed stimulation strategies, or investigated the basic physiology underpinning retinal prostheses. Current technologies are summarized, along with future challenges that face the field

    PREP2: A biomarker‐based algorithm for predicting upper limb function after stroke

    Get PDF
    Objective Recovery of motor function is important for regaining independence after stroke, but difficult to predict for individual patients. Our aim was to develop an efficient, accurate, and accessible algorithm for use in clinical settings. Clinical, neurophysiological, and neuroimaging biomarkers of corticospinal integrity obtained within days of stroke were combined to predict likely upper limb motor outcomes 3 months after stroke. Methods Data from 207 patients recruited within 3 days of stroke [103 females (50%), median age 72 (range 18–98) years] were included in a Classification and Regression Tree analysis to predict upper limb function 3 months poststroke. Results The analysis produced an algorithm that sequentially combined a measure of upper limb impairment; age; the presence or absence of upper limb motor evoked potentials elicited with transcranial magnetic stimulation; and stroke lesion load obtained from MRI or stroke severity assessed with the NIHSS score. The algorithm makes correct predictions for 75% of patients. A key biomarker obtained with transcranial magnetic stimulation is required for one third of patients. This biomarker combined with NIHSS score can be used in place of more costly magnetic resonance imaging, with no loss of prediction accuracy. Interpretation The new algorithm is more accurate, efficient, and accessible than its predecessors, which may support its use in clinical practice. While further work is needed to potentially incorporate sensory and cognitive factors, the algorithm can be used within days of stroke to provide accurate predictions of upper limb functional outcomes at 3 months after stroke. www.presto.auckland.ac.n

    Smaller spared subcortical nuclei are associated with worse post-stroke sensorimotor outcomes in 28 cohorts worldwide

    Get PDF
    Up to two-thirds of stroke survivors experience persistent sensorimotor impairments. Recovery relies on the integrity of spared brain areas to compensate for damaged tissue. Deep grey matter structures play a critical role in the control and regulation of sensorimotor circuits. The goal of this work is to identify associations between volumes of spared subcortical nuclei and sensorimotor behaviour at different timepoints after stroke. We pooled high-resolution T1-weighted MRI brain scans and behavioural data in 828 individuals with unilateral stroke from 28 cohorts worldwide. Cross-sectional analyses using linear mixed-effects models related post-stroke sensorimotor behaviour to non-lesioned subcortical volumes (Bonferroni-corrected, P < 0.004). We tested subacute (≤90 days) and chronic (≥180 days) stroke subgroups separately, with exploratory analyses in early stroke (≤21 days) and across all time. Sub-analyses in chronic stroke were also performed based on class of sensorimotor deficits (impairment, activity limitations) and side of lesioned hemisphere. Worse sensorimotor behaviour was associated with a smaller ipsilesional thalamic volume in both early (n = 179; d = 0.68) and subacute (n = 274, d = 0.46) stroke. In chronic stroke (n = 404), worse sensorimotor behaviour was associated with smaller ipsilesional putamen (d = 0.52) and nucleus accumbens (d = 0.39) volumes, and a larger ipsilesional lateral ventricle (d = -0.42). Worse chronic sensorimotor impairment specifically (measured by the Fugl-Meyer Assessment; n = 256) was associated with smaller ipsilesional putamen (d = 0.72) and larger lateral ventricle (d = -0.41) volumes, while several measures of activity limitations (n = 116) showed no significant relationships. In the full cohort across all time (n = 828), sensorimotor behaviour was associated with the volumes of the ipsilesional nucleus accumbens (d = 0.23), putamen (d = 0.33), thalamus (d = 0.33) and lateral ventricle (d = -0.23). We demonstrate significant relationships between post-stroke sensorimotor behaviour and reduced volumes of deep grey matter structures that were spared by stroke, which differ by time and class of sensorimotor measure. These findings provide additional insight into how different cortico-thalamo-striatal circuits support post-stroke sensorimotor outcomes

    Effect of Stimulus and Number of Sweeps on the Neonate Auditory Brainstem Response

    No full text

    Ein dermographisches Symptom bei Lungentuberkulose

    No full text

    A monograph of Heterospathe (Areceae, Arecaceae) in New Guinea

    No full text
    A revision of the genus Heterospathe Scheff. in New Guinea and immediately adjacent islands is presented. We recognise 14 species for this area. Taxonomic and nomenclatural changes are outlined, and each species is thoroughly described, mapped and illustrated. A key to the species in the area is included as well as preliminary IUCN Red List Assessments

    Are long stimulus pulse durations the answer to improving spatial resolution in retinal prostheses?

    No full text
    Retinal prostheses can provide artificial vision to patients with degenerate retinae by electrically stimulating the remaining inner retinal neurons. The evoked perception is generally adequate for light localization, but of limited spatial resolution owing to the indiscriminate activation of multiple retinal cell types, leading to distortions in the perceived image. Here we present a perspective on a recent work by Weitz and colleagues who demonstrate a focal confinement of retinal ganglion cell (RGC) activation when using extended pulse durations in the stimulation waveform. Using real-time calcium imaging, they provide evidence that long pulse durations selectively stimulate inner retinal neurons, whilst avoiding unwanted axonal activations. The application of this stimulation technique may provide enhanced spatial resolution for retinal prosthesis users. These experiments provide a robust analysis of the effects of increasing pulse duration and introduce the potential for alternative stimulation paradigms in retinal prostheses
    corecore