633 research outputs found

    Generic Subsequence Matching Framework: Modularity, Flexibility, Efficiency

    Get PDF
    Subsequence matching has appeared to be an ideal approach for solving many problems related to the fields of data mining and similarity retrieval. It has been shown that almost any data class (audio, image, biometrics, signals) is or can be represented by some kind of time series or string of symbols, which can be seen as an input for various subsequence matching approaches. The variety of data types, specific tasks and their partial or full solutions is so wide that the choice, implementation and parametrization of a suitable solution for a given task might be complicated and time-consuming; a possibly fruitful combination of fragments from different research areas may not be obvious nor easy to realize. The leading authors of this field also mention the implementation bias that makes difficult a proper comparison of competing approaches. Therefore we present a new generic Subsequence Matching Framework (SMF) that tries to overcome the aforementioned problems by a uniform frame that simplifies and speeds up the design, development and evaluation of subsequence matching related systems. We identify several relatively separate subtasks solved differently over the literature and SMF enables to combine them in straightforward manner achieving new quality and efficiency. This framework can be used in many application domains and its components can be reused effectively. Its strictly modular architecture and openness enables also involvement of efficient solutions from different fields, for instance efficient metric-based indexes. This is an extended version of a paper published on DEXA 2012.Comment: This is an extended version of a paper published on DEXA 201

    Phase II trial of intrapleural paclitaxel injection for non-small-cell lung cancer patients with malignant pleural effusions

    Get PDF
    AbstractA phase II clinical trial of intrapleural paclitaxel injection for malignant effusions of non-small-cell lung cancer (NSCLC) was conducted in order to evaluate the efficacy and toxicity profile of paclitaxel pleurodesis in patients with malignant effusions. From February to May of 1996, 15 NSCLC patients with malignant pleural effusions were enrolled on study. After adequate drainage and assurance of lung re-expansion, paclitaxel 125 mg m−2 diluted in normal saline was infused through a preinserted pig-tail catheter which was removed 2 h later. Chest radiography and sonography were scheduled 4 days later; depending on whether there remained a significant amount of pleural effusion, further drainage by needle thoracentesis or by a pig-tail catheter was performed.All patients were assessable for toxicity. Ipsilateral chest and/or shoulder pain, fever, facial flushing and nausea were the most frequent side-effects. Grade 4 neutropenia, grade 3 anaemia, and grade 3 renal impairment occurred in one patient each. Fourteen patients were evaluable for response at the end of the fourth week. Overall response rate of pleural effusion in evaluable patients was 92·9%, with a complete response rate of 28·6%. There was one out of 14 evaluable patients whose measurable tumour lesion decreased by more than 50% (partial response). No disease progression was noted among evaluable patients at the end of the fourth week. It is concluded that paclitaxel is a useful agent for the treatment of malignant pleural effusions. Because of its relatively low systemic toxicity, intrapleural paclitaxel injection in combination with systemic chemotherapy or radiotherapy can be considered in treating NSCLC patients with malignant pleural effusions

    A sub-cm micromachined electron microscope

    Get PDF
    A new approach for fabricating macroscopic (approximately 10x10x10 mm(exp 3)) structures with micron accuracy has been developed. This approach combines the precision of semiconductor processing and fiber optic technologies. A (100) silicon wafer is anisotropically etched to create four orthogonal v-grooves and an aperture on each 10x12 mm die. Precision 308 micron optical fibers are sandwiched between the die to align the v-grooves. The fiber is then anodically bonded to the die above and below it. This procedure is repeated to create thick structures and a stack of 5 or 6 die will be used to create a miniature scanning electron microscope (MSEM). Two die in the structure will have a segmented electrode to deflect the beam and correct for astigmatism. The entire structure is UHV compatible. The performance of an SEM improves as its length is reduced and a sub-cm 2 keV MSEM with a field emission source should have approximately 1 nm resolution. A low voltage high resolution MSEM would be useful for the examination of biological specimens and semiconductors with a minimum of damage. The first MSEM will be tested with existing 6 micron thermionic sources. In the future a micromachined field emission source will be used. The stacking technology presented in this paper can produce an array of MSEMs 1 to 30 mm in length with a 1 mm or larger period. A key question being addressed by this research is the optimum size for a low voltage MSEM which will be determined by the required spatial resolution, field of view, and working distance

    Anatomy of the Soft-Photon Approximation in Hadron-Hadron Bremsstrahlung

    Full text link
    A modified Low procedure for constructing soft-photon amplitudes has been used to derive two general soft-photon amplitudes, a two-s-two-t special amplitude MμTsTtsM^{TsTts}_{\mu} and a two-u-two-t special amplitude MμTuTtsM^{TuTts}_{\mu}, where s, t and u are the Mandelstam variables. MμTsTtsM^{TsTts}_{\mu} depends only on the elastic T-matrix evaluated at four sets of (s,t) fixed by the requirement that the amplitude be free of derivatives (\partialT/\partials and /or \partialT/t\partial t). Likewise MμTuTtsM^{TuTts}_{\mu} depends only on the elastic T-matrix evaluated at four sets of (u,t). In deriving these amplitudes, we impose the condition that MμTsTtsM^{TsTts}_{\mu} and MμTuTtsM^{TuTts}_{\mu} reduce to MˉμTsTts\bar{M}^{TsTts}_{\mu} and MˉμTuTts\bar{M}^{TuTts}_{\mu}, respectively, their tree level approximations. The amplitude MˉμTsTts\bar{M}^{TsTts}_{\mu} represents photon emission from a sum of one-particle t-channel exchange diagrams and one-particle s-channel exchange diagrams, while the amplitude MˉμTuTts\bar{M}^{TuTts} _{\mu} represents photon emission from a sum of one-particle t-channel exchange diagrams and one-particle u-channel exchange diagrams. The precise expressions for MˉμTsTts\bar{M}^{TsTts}_{\mu} and MˉμTuTts\bar{M}^{TuTts}_{\mu} are determined by using the radiation decomposition identities of Brodsky and Brown. We point out that it is theoretically impossible to describe all bremsstrahlung processes by using only a single class of soft-photon amplitudes. At least two different classes are required: the amplitudes which depend on s and t or the amplitudes which depend on u and t. When resonance effects are important, the amplitude MμTsTtsM^{TsTts}_{\mu}, not MμLow(st)M^{Low(st)}_{\mu}, should be used. For processes with strong u-channel exchange effects, the amplitude MμTuTtsM^{TuTts}_{\mu} should be the first choice.Comment: 49 pages report # LA-UR-92-270

    Estimating Grid-Induced Errors in CFD by Discrete-Error-Transport Equations

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/77113/1/AIAA-2004-656-838.pd

    6-Thioguanine blocks SARS-CoV-2 replication by inhibition of PLpro

    Get PDF
    The emergence of SARS-CoV-2 has led to a global health crisis that, in addition to vaccines and immunomodulatory therapies, calls for the identification of antiviral therapeutics. The papain-like protease (PLpro) activity of nsp3 is an attractive drug target as it is essential for viral polyprotein cleavage and for deconjugation of ISG15, an antiviral ubiquitin-like protein. We show here that 6-Thioguanine (6-TG), an orally available and widely available generic drug, inhibits SARS-CoV-2 replication in Vero-E6 cells with an EC50 of approximately 2 μM. 6-TG also inhibited PLpro-catalyzed polyprotein cleavage and de-ISGylation in cells and inhibited proteolytic activity of the purified PLpro domai

    Eosinophil and T Cell Markers Predict Functional Decline in COPD Patients

    Get PDF
    BACKGROUND. The major marker utilized to monitor COPD patients is forced expiratory volume in one second (FEV1). However, asingle measurement of FEV1 cannot reliably predict subsequent decline. Recent studies indicate that T lymphocytes and eosinophils are important determinants of disease stability in COPD. We therefore measured cytokine levels in the lung lavage fluid and plasma of COPD patients in order to determine if the levels of T cell or eosinophil related cytokines were predictive of the future course of the disease. METHODS. Baseline lung lavage and plasma samples were collected from COPD subjects with moderately severe airway obstruction and emphysematous changes on chest CT. The study participants were former smokers who had not had a disease exacerbation within the past six months or used steroids within the past two months. Those subjects who demonstrated stable disease over the following six months (ΔFEV1 % predicted = 4.7 ± 7.2; N = 34) were retrospectively compared with study participants who experienced a rapid decline in lung function (ΔFEV1 % predicted = -16.0 ± 6.0; N = 16) during the same time period and with normal controls (N = 11). Plasma and lung lavage cytokines were measured from clinical samples using the Luminex multiplex kit which enabled the simultaneous measurement of several T cell and eosinophil related cytokines. RESULTS AND DISCUSSION. Stable COPD participants had significantly higher plasma IL-2 levels compared to participants with rapidly progressive COPD (p = 0.04). In contrast, plasma eotaxin-1 levels were significantly lower in stable COPD subjects compared to normal controls (p < 0.03). In addition, lung lavage eotaxin-1 levels were significantly higher in rapidly progressive COPD participants compared to both normal controls (p < 0.02) and stable COPD participants (p < 0.05). CONCLUSION. These findings indicate that IL-2 and eotaxin-1 levels may be important markers of disease stability in advanced emphysema patients. Prospective studies will need to confirm whether measuring IL-2 or eotaxin-1 can identify patients at risk for rapid disease progression.National Heart, Lung, and Blood Institute (NO1-HR-96140, NO1-HR-96141-001, NO1-HR-96144, NO1-HR-96143; NO1-HR-96145; NO1-HR-96142, R01HL086936-03); The Flight Attendant Medical Research Institute; the Jo-Ann F. LeBuhn Center for Chest Diseas

    A randomised phase II study of weekly paclitaxel or vinorelbine in combination with cisplatin against inoperable non-small-cell lung cancer previously untreated

    Get PDF
    [[abstract]]Phase II studies have suggested that weekly paclitaxel has a higher response rate and better toxicity profile than the conventional schedule of once every 3 or 4 weeks. Our aim was to evaluate the efficacy of weekly paclitaxel plus cisplatin (PC) vs vinorelbine plus cisplatin (VC) in chemonaive non-small-cell lung cancer (NSCLC) patients. From October 2000 to May 2002, 140 patients were enrolled. The treatment dose was P 66 mg m(-2) intravenous infusion (im.) on days 1, 8, and 15, and C 60 mg m(-2) i.v. on day 15, or V 23 mg m(-2) i.V. on days 1, 8, and 15, and C 60 mg m(-2) i.v. on day 15, every 4 weeks. In all, 28 1 cycles of PC and 307 cycles of VC were given to the patients in the PC and VC arms, respectively. There were 26 partial responses and one complete response (overall 38.6%) in the PC arm, and no complete responses, but 27 partial responses (overall 38.6%) in the VC arm. Myelosuppression was more common in the VC arm (P<0.001). Peripheral neuropathy and myalgia were significantly more common in the PC arm (P<0.001). The median time to disease progression was 6 months in the PC arm and 8.4 months in the VC arm (P=0.0344). The median survival time was 11.7 months in the PC arm and 15.4 months in the VC arm (P = 0.297). We concluded that weekly PC is not suggested for NSCLC patients due to the relatively shorter progression-free survival and more common nonhaematological toxicities

    Plasma metabolite profiles in children with current asthma

    Full text link
    Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/146270/1/cea13183.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/146270/2/cea13183_am.pd
    corecore