35 research outputs found

    A multicentre, prospective, randomised controlled trial to assess the safety and effectiveness of cooling as an adjunctive therapy to percutaneous intervention in patients with acute myocardial infarction: the COOL AMI EU Pivotal

    Get PDF
    Despite primary PCI (PPCI), ST-elevation myocardial infarction (STEMI) can still result in large infarct size (IS). New technology with rapid intravascular cooling showed positive signals for reduction in IS in anterior STEMI.We investigated the effectiveness and safety of rapid systemic intravascular hypothermia as an adjunct to PPCI in conscious patients, with anterior STEMI, without cardiac arrest.Hypothermia was induced using the ZOLL® Proteus™ intravascular cooling system. After randomisation of 111 patients, 58 to hypothermia and 53 to control groups, the study was prematurely discontinued by the sponsor due to inconsistent patient logistics between the groups resulting in significantly longer total ischaemic delay in the hypothermia group (232 vs 188 minutes; p<0.001).There were no differences in angiographic features and PPCI result between the groups. Intravascular temperature at wire crossing was 33.3+0.9°C. Infarct size/left ventricular mass (IS/LV) by cardiac magnetic resonance (CMR) at day 4-6 was 21.3% in the hypothermia group and 20.0% in the control group (p=0.540). Major adverse cardiac events at 30 days increased non-significantly in the hypothermia group (8.6% vs 1.9%; p=0.117) while cardiogenic shock (10.3% vs 0%; p=0.028) and paroxysmal atrial fibrillation (43.1% vs 3.8%; p<0.001) were significantly more frequent in the hypothermia group.The ZOLL Proteus intravascular cooling system reduced temperature to 33.3°C before PPCI in patients with anterior STEMI. Due to inconsistent patient logistics between the groups, this hypothermia protocol resulted in a longer ischaemic delay, did not reduce IS/LV mass and was associated with increased adverse events

    Outcomes and regional differences in practice in a worldwide coronary stent registry

    Get PDF
    Objective: The primary objective was to assess the performance of a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer in an all comer population. The secondary objective was to detail differences in contemporary percutaneous coronary intervention (PCI) practice worldwide. Methods: e-Ultimaster was an all-comer, prospective, global registry (NCT02188355) with independent event adjudication enrolling patients undergoing PCI with the study stent. The primary outcome measure was target lesion failure (TLF) at 1 year, defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularisation. Data were stratified according to 4 geographical regions. Results: A total of 37 198 patients were enrolled (Europe 69.2%, Asia 17.8%, Africa/Middle East 6.6% and South America/Mexico 6.5%) and 1-year follow-up was available for 35 389 patients (95.1%). One-year TLF occurred in 3.2% of the patients, ranging from 2% (Africa/Middle East) to 4.1% (South America/Mexico). In patients with acute coronary syndrome, potent P2Y(12) inhibitors were prescribed in 48% of patients at discharge, while at 1 year 72% were on any dual antiplatelet therapy. Lipid-lowering treatment was administered in 80.9% and 75.5% of patients at discharge and 1 year, respectively. Regional differences in the profile of the treated patients as well as in PCI practice were reported. Conclusions: In this investigation with worldwide representation, contemporary PCI using a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer was associated with low 1-year TLF across clinical presentations and continents. Suboptimal adherence to current recommendations around antiplatelet and lipid lowering treatments was detected

    Recovery and prognostic value of myocardial strain in ST-segment elevation myocardial infarction patients with a concurrent chronic total occlusion

    Get PDF
    Objectives: Global left ventricular (LV) function is routinely used to assess cardiac function; however, myocardial strain is able to identify more subtle dysfunction. We aimed to determine the recovery and prognostic value of featuring tracking (FT) cardiovascular magnetic resonance (CMR) strain in ST-segment elevation myocardial infarction (STEMI) patients with a concurrent chronic total occlusion (CTO). Methods: In the randomized EXPLORE trial, there was no significant difference in global LV functio

    Recovery of right ventricular function and strain in patients with ST-segment elevation myocardial infarction and concurrent chronic total occlusion

    Get PDF
    The right ventricle (RV) is frequently involved in ST-segment elevation myocardial infarction (STEMI) when the culprit or concurrent chronic total occlusion (CTO) is located in the right coronary artery (RCA). We investigated RV function recovery in STEMI-patients with concurrent CTO. In EXPLORE, STEMI-patients with concurrent CTO were randomized to CTO percutaneous coronary intervention (PCI) or no CTO-PCI. We analyzed 174 EXPLORE patients with serial cardiovascular magnetic resonance imaging RV data (baseline and 4-month follow-up), divided into three groups: CTO-RCA (CTO in RCA, culprit in non-RCA; n = 89), IRA-RCA (infarct related artery [IRA] in RCA, CTO in non-RCA; n = 56), and no-RCA (culprit and CTO not in RCA; n = 29). Tricuspid annular plane systolic excursion (TAPSE), RV ejection fraction (RVEF), RV global longitudinal strain (GLS) and free wall longitudinal strain (FWLS) were measured. We found that RV strain and TAPSE improved in IRA-RCA and CTO-RCA (irrespective of CTO-PCI) at follow-up, but not in no-RCA. Only RV FWLS was different among groups at baseline, which was lower in IRA-RCA than no-RCA (− 26.0 ± 8.3% versus − 31.0 ± 6.4%, p = 0.006). Baseline RVEF, RV end-diastolic volume and TAPSE were associated with RVEF at 4 months. RV function parameters were not predictive of 4 year mortality, although RV GLS showed additional predictive value for New York Heart Association Classification > 1 at 4 months. In conclusion, RV parameters significantly improved in patients with acute or chronic RCA occlusion, but not in no-RCA patients. RV FWLS was the only RV parameter able to discriminate between acute ischemic and non-ischemic myocardium. Moreover, RV GLS was independently predictive for functional status

    One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries

    No full text
    Objectives: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. Methods: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. Results: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). Conclusions: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES

    Five-year clinical performance of a biodegradable polymer-coated biolimus-eluting stent in unselected patients

    No full text
    OBJECTIVE: To evaluate the long-term follow-up of the unrestricted use of a biodegradable polymer-coated drug-eluting stent in patients undergoing percutaneous coronary intervention (PCI). METHODS: The Nobori 2 study was a prospective, multicentre, observational registry evaluating the safety and the efficacy of the biodegradable polymer biolimus-eluting stent (BP-BES) among 3067 patients recruited at 125 international sites. The primary combined endpoint was a composite of cardiac death, myocardial infarction and target-lesion revascularisation (TLR). RESULTS: Five-year follow-up was available in 2738 (89.3%) patients. The combined endpoint occurred in 268 patients (10%, 95% CIs 8.9% to 11.3%) at 5 years, with 3.9% of events during the first year and 6.2% during years 1-5 of follow-up. Cumulative rates of TLR and definite/probable stent thrombosis were 5.3% (95% CI 4.5% to 6.3%) and 1.1% (95% CI 0.8% to 1.6%), respectively. Between 1 and 5 years, TLR and very late stent thrombosis rates were 3.5% (95% CI 2.8% to 4.4%) and 0.6% (95% CI 0.3% to 1.1%), respectively. Previous PCI (HR, 2.05, 95% CI 1.68 to 2.50), moderate-to-severe renal disease (HR, 1.89, 95% CI 1.30 to 2.74) and peripheral vascular disease (HR, 1.86, 95% CI 1.38 to 2.52) were the three most powerful independent predictors of the combined endpoint at 5 years. CONCLUSIONS: The final 5-year follow-up of the Nobori 2 registry demonstrates the safety and effectiveness of the BP-BES in an unselected, broadly inclusive cohort of PCI patients, highlighting the excellent performance of this coronary stent technology after polymer biodegradation

    Impact of the number of modifiable risk factors on clinical outcomes after percutaneous coronary intervention: An analysis from the e-Ultimaster registry.

    No full text
    A substantial proportion of the patients undergoing percutaneous coronary intervention (PCI) have none of the of standard modifiable cardiovascular risk factors (SMuRFs): hypertension, diabetes, hypercholesterolaemia and smoking. The aim of this analysis was to compare clinical outcomes after PCI according to the number of SMuRFs. Patients with an indication for a PCI were stratified based upon the number of SMuRFs: 0, 1, 2 or 3-4. The primary outcome was target lesion failure (TLF), a composite of cardiac death, target vessel-related myocardial infarction or clinically driven target lesion revascularization at 1-year. Inverse weighted propensity score (IWPS) adjustment was performed to adjust for differences in baseline characteristics. The prevalence of SMuRFs was: 0 SMuRF 16.4 %; 1 SMuRF 27.8 %; 2 SMuRFs 34.7 % and 3-4 SMuRFs 21.1 %. Patients without SMuRFs were younger, more likely to be male and had less complex coronary artery disease. The incidence of TLF increased with the number of SMuRFs: 2.65 %, 2.75 %, 3.23 %, and 4.24 %, P  < 0.001. The relative risk (RR) for a TLF was 60 % higher (95 % confidence interval 1.32-1.93, p < 0.01) for patients with 3-4 SMuRFs compared to patients without SMuRFs. The trend remained (P  < 0.01) after IWPS with TLF rates of 2.88 %, 2.64 %, 2.88 % and 3.65 %. The RR for a TLF was 27 % higher (95 % CI 1.05-1.53, p < 0.01). The incidence of clinical events at 1-year increased with the number of SMuRFs. While patients without SMuRFs have a relatively favourable risk profile, more research is needed to optimize therapeutic management in the majority of patients. [Abstract copyright: © 2024 The Author(s).
    corecore