330 research outputs found

    A classe... amb corbata!

    Get PDF
    En aquest article mostrem com els alumnes resolen un problema produint les seves pròpies representacions del procediment de construir un nus de corbata. Els alumnes fan servir aquestes representacions per a generar nous nusos i per a calcular el nombre de nusos de corbata en funció dels moviments necessaris per construir-los. Tot això dins el marc d'una metodologia que afavoreix els processos comunicatius a l'aula.This paper shows how students solve a problemcreating their own representations of the process of doing a tie knot. Students use these representations to generate new knots and to calculate the number of tie knots depending on the requiredmovements to tie them. This is done in the context of a methodology that benefits the communication process in the classroom

    Artificial neural network algorithms for active noise control applications

    Get PDF
    6 pages, 5 figures.-- PACS nr.: 43.50 Ki.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3rd Iberian Congress on Acoustics.-- Special issue of the journal Revista de Acústica, Vol. XXXIII, year 2002.This paper shows the use of several methods commonly applied to training Artificial Neural Networks (ANN) in Active Noise Control (ANC) systems. Although ANN are usually focused on off-line training, real-time systems can take advantage of modern microprocessors in order to use these techniques. A theoretical study of which of these methods suit best in ANC systems is presented. The results of several simulations will show their effectiveness.This work has been supported by the Comisión Interministerial de Ciencia y Tecnología (CICYT) under the project DPI2001-1613-C02-01.Peer reviewe

    Control activo global multicanal del ruido de baja frecuencia en recintos

    Get PDF
    9 pp.-- PACS nr.: 43.50.Ki.-- Comunicación presentada en los siguientes congresos: XXX Jornadas Nacionales de Acústica – TecniAcústica 1999. Encuentro Ibérico de Acústica (Ávila, 20-22 Octubre 1999).Publicado en número especial de la Revista de Acústica: Vol 30(1999).[EN] In this work, an Active Noise Control system has been implemented in a slightly damped room harmonically excited. We are interested in the reduction of the sound pressure level over the whole enclosure, global control, so we have to consider the modal overlapping in order to discriminate between diffuse and modal field. The sum of the square pressure levels at the discrete sensor positions has been reduced using the Filtered-X LMS algorithm. Important reductions can be obtained when the secondary sources are far away from the primary source, but the best results are achieved when the secondary sources are closed to the primary one.[ES] En este trabajo se ha realizado una verificación experimental de las posibilidades de las técnicas de Control Activo del Ruido (CAR) en recintos. Concretamente, en un recinto paralelepipédico de dimensiones 6.81 x 5.23 x 3.38 m, ligeramente amortiguado y excitado armónicamente. Debido a que la forma del recinto se adapta perfectamente a coordenadas cartesianas y trabajamos en un margen de bajas frecuencias, la ecuación de ondas es exactamente resoluble y podemos expresar la solución utilizando teoría de modos normales sin necesidad de recurrir a procedimientos numéricos más complicados. Para medir la respuesta global del recinto se utiliza la energía potencial acústica medida en un número discreto de sensores de error, minimizándose el cuadrado de la presión en esas posiciones mediante un sistema comercial que implementa el algoritmo FX-LMS.Las aplicaciones prácticas de las técnicas CAR en recintos van dirigidas esencialmente al control del ruido de baja frecuencia en las cabinas de los aviones y en el interior de los vehículos, para el control del booming del habitáculo. En estos problemas es imposible aplicar técnicas de control pasivo sin aumentar de forma considerable el peso, y por tanto, el consumo. En ambos casos existen numerosos trabajos realizados con éxito.Este trabajo ha sido posible gracias al soporte financiero de la Comisión Interministerial de Ciencia y Tecnología (Proyecto AMB97-1175-C03-01).Peer reviewe

    Predicción del campo acústico en recintos con geometría irregular para un sistema de control activo del ruido

    Get PDF
    7 pp.-- PACS nr.: 43.50.Ki.-- Comunicación presentada en: XXXII Congreso Nacional de Acústica – TecniAcústica 2001 y Encuentro Ibérico de Acústica (Logroño, 17-19 Octubre 2001).Publicado en número especial de la Revista de Acústica: Vol 32(2001).[EN] The distribution of the sensors and actuators in an active noise control system imposes a limit in the maximum attenuation levels to be reached. In real applications, irregular shaped cavities are often involved, whose modal characteristics are fundamental to a better understanding of the sound mechanism and any active noise reduction to be taken. The most popular alternatives are numerical methods. In this work, an approach is presented for computing acoustic properties of cavities of arbitrary shape, approximating the cavity geometry by a set of rectangular subcavities. The adjacent ones are jointed together by means of vibrating membranes.[ES] La distribución espacial de los tranductores en un sistema de control activo del ruido impone un limite a los valores de atenuación máximos que pueden obtenerse. En la mayoría de los problemas que se presentan en la práctica aparecen geometrías irregulares, cuya respuesta acústica no puede predecirse utilizando métodos clásicos de separación de variables. Las alternativas más utilizadas en estos casos son los métodos numéricos. En este trabajo se utilizan un método que consiste en la discretizacion de la cavidad por subcavidades más pequeñas cuya geometría se conoce. Las cavidades adyacentes se acoplan a través de membranas vibrantes.Este trabajo ha sido posible gracias al soporte financiero de la Comisión Interministerial de Ciencia y Tecnología (Proyecto AMB99-1095-C02-01).Peer reviewe

    Aplicación de acústica cualitativa en el control activo de ruido

    Get PDF
    6 pp.-- PACS nr.: 43.50.Qp.-- Comunicación presentada en los siguientes congresos: XXX Jornadas Nacionales de Acústica – TecniAcústica 1999. Encuentro Ibérico de Acústica (Ávila, 20-22 Octubre 1999).Publicado en número especial de la Revista de Acústica: Vol 30(1999).To determine the hypothetical subjective effectiveness of an active noise control system, two simple experiments were performed. The two tests are based on the same type of judgements made by the subjects: pair comparisons. Also a simple test of auditive perception was conducted to equalise the loudness level of the noise and the calibration signal. The results of the two tests were in general agreement with the active noise control measures.Este trabajo ha sido posible gracias al soporte financiero de la Comisión Interministerial de Ciencia y Tecnología. (Proyecto AMB97-1175-C02-01).Peer reviewe

    Comparación CAR/CAAE en una placa delgada en soporte simple

    Get PDF
    6 pp.-- PACS nr.: 43.50.Ki.-- Comunicación presentada en: XXXII Congreso Nacional de Acústica – TecniAcústica 2001 y Encuentro Ibérico de Acústica (Logroño, 17-19 Octubre 2001).Publicado en número especial de la Revista de Acústica: Vol 32(2001).[EN] The main objective of this work is to compare the results of applying Active Noise Control (ANC) and Active Structural Acoustic Control (ASAC) to a simply supported plate. In both cases the exciting source is a piezoceramic. As actuator, a loudspeaker and a similar piezoceramic are used in the ANC and ASAC systems, respectively. A control unity which implements both FXLMS and FULMS algorithms is used to generate the secondary field in order to reduce the noise radiated by the plate.[ES] El principal objetivo de este trabajo es comparar los resultados obtenidos al aplicar técnicas de Control Activo del Ruido (CAR) y de Control Activo Acústico Estructural (CAAE) a una placa simplemente soportada. En ambos casos la fuente de excitación es una piezocerámica. Como actuador se utiliza un altavoz y una piezocerámica del mismo tipo, en los dispositivos CAR y CAAE respectivamente. La unidad de control utilizada, que implementa los algoritmos FXLMS y FULMS, genera el campo secundario para reducir el ruido radiado por la placa.Este trabajo ha sido posible gracias a la financiación de la CICYT, a través del Proyecto AMB99-1095-C02-01.Peer reviewe

    Localización óptima de los transductores en un sistema de control activo en un recinto

    Get PDF
    7 pp.-- PACS nr.: 43.50.Kj.-- Comunicación presentada en los siguientes congresos: II Congreso Iberoamericano de Acústica. XXXI Congreso Nacional de Acústica – TecniAcústica 2000. II Jornadas Iberoamericanas de Ultrasonidos. II Congreso Ibérico de Acústica. EAA Symposium on Architectural Acoustics (Madrid, 16-20 Octubre 2000).Publicado también en número especial de la Revista de Acústica, Vol. XXXI, año 2000.[EN] The distribution of the sensors and actuators for an ANC system has been optimised in a small enclosure using the experimental measurement of the transfer functions. The objective function used is the sum of square sound pressure values at a discrete number of points inside. The attenuation for each different combination is calculated from the response of the secondary sources at these points and from the primary field at the same sensors. The sound field at a fixed height has been determined using a grid of microphones uniformly distributed.[ES] En este trabajo se han determinado las posiciones óptimas de los transductores en un sistema de Control Activo del Ruido en un recinto mediante la medida experimental de las funciones de transferencia. Los valores de la atenuación obtenidos se determinan mediante la suma de los cuadrados de la presión en un número discreto de puntos antes y después de la cancelación activa. El campo de presión sonora a una altura fija se determina mediante una malla de micrófonos distribuidos de forma uniforme.Este trabajo ha sido posible gracias al soporte financiero de la Comisión Interministerial de Ciencia y Tecnología (Proyecto AMB99-1095-C02-01).Peer reviewe

    Detección de modos estructurales en barras con cambios de espesor

    Get PDF
    7 pp.-- PACS nr.: 43.40.Vn.-- Comunicación presentada en los siguientes congresos: XXXIV Congreso Nacional de Acústica – TecniAcústica 2003. Encuentro Ibérico de Acústica. EAA Symposium on Architectural Acoustics. Expoacústica 2003 (Bilbao, 15-17 Octubre 2003).Publicado en número especial de la Revista de Acústica: Vol. 34, núm. 3-4 (2003).[EN] This paper studies the correct detection of structural modes using PVDF sensors for a bar having a non-uniform mass distribution. The general orthogonality condition involving the mass distribution is applied, and the sensor design should account for non-sinusoidal modeshapes and the mass distribution for the correct detection of individual modes. Simulations are used to compare different sensors designs implementing either or both of these requirements for a bar with one centralized doubling of thickness. Also, the passive effect of the driving piezoceramic actuators is considered.[ES] Este trabajo estudia la detección correcta de modos estructurales usando sensores de PVDF para una barra que tiene una distribución no-uniforme de masa. Se aplica la condición general de ortogonalidad involucrando la distibución de masa, y el diseño del sensor debería tener en cuenta la forma no senoidal de los modos y la distribución de masa para la detección correcta de modos individuales. Mediante simulaciones se comparan diferentes diseños de sensores implementando uno o ambos de estos requisitos para una barra con espesor doble en el centro. También, se tiene en cuenta el efecto pasivo de los actuadores piezocerámicos.El primer autor agradece la financiación de una beca Marie Curie Individual Fellowship de la Comisión Europea (Contrato: HPMF-CT-2001-01166).Peer reviewe

    Underwater acoustic tank evaluation of acoustic properties of samples using spectrally dense signals

    Get PDF
    4 pp.-- Comunicación presentada en: Joint Meeting "Berlin 99": 137th regular meeting of the Acoustical Society of America ; 2nd convention of the EAA: Forum Acusticum - integrating the 25th German Acoustics DAGA Conference. Berlin, March 14-19, 1999.This paper deals with exploring the availability and reliability of subtraction techniques, based on spectrally dense signals such as Maximun Length Sequences, in evaluating the echo reduction losses of samples of interest underwater acoustics. These techniques, first employed in air acoustics, were adapted to the underwater environment. Experimental results show how a measurement can be accomplished and the limitations produced by the actual available combination of soft, hardware and tank and sample dimensions.The authors wish to acknowledge the help given by the CICYT, Project AMB97-1175-CO301, for having the opportunity to use the software, hardware and related facilities in carrying out the work described by this paper.Peer reviewe
    corecore