6 research outputs found

    Impact of Periodontal Diseases on Health-Related Quality of Life of Users of the Brazilian Unified Health System

    Get PDF
    Objective. This study assessed the impact of periodontal diseases on health-related quality of life of adult users of the Brazilian Unified Health System. Study Design. A cross-sectional study was conducted on an outpatient basis. The sample included 151 adults treated in the Periodontics section at Dental Specialty Centres of Juiz de Fora (Minas Gerais, Brazil). The Oral Health Impact Profile (OHIP-14) measured the impact of periodontal disease on quality of life. Participants were interviewed to obtain self-perception of general and oral health and socioeconomic data, and dental records were consulted to obtain periodontal status data. The values of central tendency of the OHIP-14 were compared with socioeconomic, demographic, and self-reported health predictors using nonparametric tests. The final analysis was performed using multiple linear regressions. Results. The results showed that psychological discomfort and physical disability exhibited a negative impact. The following variables can explain approximately 27% of the impact of oral health conditions on health-related quality of life in this group: periodontal disease, self-perceived oral health, and the need to use or replace dental prosthesis. Conclusion. The need for prosthetic rehabilitation and worse periodontal status are associated with health-related quality of life, which can be predicted by the self-perception of health

    Avaliação da resistência a corrosão e da microestrutura de superfície de mini-implantes ortodônticos utilizados

    Get PDF
    Introduction: The orthodontic mini-implants as biomaterials, in addition to mechanical resistance, shall have good corrosion resistance in the physiological environment in which they are inserted. Objective: To assess the corrosion resistance and the surface microstructure of orthodontic mini-implants kept in their bone insertion sites and removed after use. Material and methods: Twenty orthodontic mini-screw-implants made from Ti6AI4V alloy were assessed; divided into 2 groups of 10 units: the control group (as-received from the manufacturer) and the test group (which remained stable in their bone insertion sites and that have been removed after use). The visual analysis of the thread surface of mini-implants was performed with a scanning electron microscope (SEM) and the evaluation of corrosion resistance with the cyclic potentiodynamic polarisation test through which the open circuit potential (OCP), the tOCP (timing of OCP), the primary passivation current (ipp) and the primary passivation potential (Epp) were determined. Results: It has not been identified any significant difference between the groups for the studied variables, although the comparison between the OCP values has had a p-limit value (p = 0.050). SEM images of the thread surface of the mini-implants obtained from both groups showed a regular polished surface without the presence of stains or adhered particles. Only one mini-implant from the control group showed a 61% reduction in the concentration of titanium within the cavity compared to the surface of the mini-implant through an auxiliary spectrometry technique of energy dispersive x-ray (EDX), confirming the scanning electron microscopic image that shows the presence of pit from the corrosion process. Conclusion: The average stay of 230 days of orthodontic mini-implants made from Ti6Al4V alloy at bone insertion sites did not cause significant changes either in corrosion resistance nor superficial characteristics of these devices.Introdução: Os mini-implantes ortodônticos, como biomateriais, devem possuir, além de resistência mecânica, boa resistência à corrosão no meio fisiológico o qual estão inseridos. Objetivo: Avaliar a resistência à corrosão e a microestrutura de superfície de mini-implantes ortodônticos mantidos em seus sítios ósseos de inserção e removidos após sua utilização. Material e métodos: Foram avaliados vinte mini-implantes ortodônticos autoperfurantes de liga Ti6AI4V, divididos em 2 grupos de 10 unidades: grupo controle (como recebidos do fabricante) e grupo teste (que permaneceram estáveis em seus sítios ósseos de inserção e que foram removidos após sua utilização). Foi realizada a análise visual da superfície da rosca dos mini-implantes com microscópio eletrônico de varredura (MEV) e a avaliação da resistência à corrosão com o ensaio de polarização cíclica potenciodinâmica, onde foram determinados o OCP (potencial de circuito aberto), o tOCP (tempo de OCP), a ipp (corrente de passivação primária) e a Epp (potencial de passivação primário). Resultados: Não foi identificada diferença significativa entre os grupos para as variáveis estudadas, apesar de a comparação entre os valores de OCP ter tido um p-valor limite (p=0,050). As imagens de MEV da superfície de rosca dos mini-implantes do grupo controle e grupo teste obtidas demonstraram uma superfície polida e regular, sem presença de manchas ou partículas aderidas. Apenas um mini-implante do grupo controle apresentou em técnica auxiliar de espectrometria de energia dispersiva de raio-X (EDS) uma redução de 61% da concentração de titânio no interior da cavidade em relação à superfície do mini-implante), confirmando a imagem da microscopia eletrônica de varredura, a presença de um pite proveniente do processo de corrosão. Conclusão: A permanência média de 230 dias de mini-implantes ortodônticos fabricados com liga Ti6Al4V nos sítios ósseos de inserção não causou alterações significativas na resistência à corrosão e nas características superficiais destes dispositivos.FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerai

    Avaliação da resistência à corrosão de mini-implantes ortodônticos submetidos à esterilização

    Get PDF
    The aim of the present study was to evaluate the corrosion resistance and surface characteristics of new and sterilized orthodontic mini-implants. Were evaluated selfdrilling orthodontic mini-implants manufactured with Ti6AI4V alloy. The mini-implants were divided into 2 groups of 10 units: control group (control group) and test group (submitted to the sterilization process). A visual analysis of the surface of the thread of the mini-implants was carried through a scanning electron microscope (SEM) and an evaluation of the corrosion resistance, they were submitted to potentiodynamic cyclic polarization tests. From the polarization curves, the OCP (open circuit potential), ipp (primary passivation current) and Epp (primary passivation potential) values were extracted. The results showed that there was no statistically significant difference between the groups. The mini-implant thread surface analysis through MEV indicated that the surface morphology of the sterilized mini-implants was preserved, with no visible deformation, wear or corrosion characteristics. Only a miniimplant of the control group presented pite, the fact isolated and associated with imperfections of the manufacturing process. It has been concluded that the autoclaving process is not capable of altering a corrosion resistance or as superficial visual characteristics of the mini-implants.O objetivo do presente estudo foi avaliar a resistência à corrosão e as características superficiais de mini-implantes ortodônticos novos e esterilizados. Para isso foram avaliados vinte mini-implantes ortodônticos autoperfurantes fabricados com a liga Ti6AI4V. Os mini-implantes foram divididos em 2 grupos de 10 unidades: grupo controle (como recebidos do fabricante) e grupo teste (submetidos ao processo de esterilização). Foi realizada a análise visual da superfície da rosca dos miniimplantes através de um microscópio eletrônico de varredura (MEV) e para a avaliação da resistência à corrosão, eles foram submetidos a ensaios de polarização cíclica potenciodinâmica. A partir das curvas de polarização, foram extraídos os valores referentes ao OCP (potencial de circuito aberto), ipp (corrente de passivação primária) e Epp (potencial de passivação primário). Os resultados demonstraram que não houve diferenças estatisticamente significativas entre os grupos. A análise da superfície de rosca dos mini-implantes através do MEV indicou que a morfologia superficial dos mini-implantes esterilizados foi preservada, não havendo qualquer característica visível de deformação, desgaste ou corrosão. Apenas um miniimplante do grupo controle apresentou pite, fato isolado e associado a imperfeições do processo de fabricação. Concluí-se que o processo de esterilização por autoclave não foi capaz de alterar a resistência a corrosão e nem as características visuais superficiais dos mini-implantes

    A subestimativa da reabsorção radicular apical irregular em radiografias periapicais é relevante?

    No full text
    Introduction: Periodic control of root resorption during orthodontic treatment is frequently made by two-dimensional radiographic examinations, in which irregular resorptions are not detected buccolingually. Aim: Quantifying the resorbed root area of incisors with irregular apical root resorption underestimated by two-dimensional radiographic methods. Materials and Methods: Cone beam computed tomography images of 18 patients whose incisors presented irregular apical root resorption underestimated by two-dimensional radiographic methods and their contralateral correspondents without resorption were evaluated. In sound incisors, a regular apical root resorption was simulated at the same height as that of the irregularly resorbed incisors. The apical and total root surface areas of the incisors with irregular root resorption and simulated regular root resorption were measured and compared. The Student´s t test for paired samples was used at a level of significance of 0.05. Results: The apical area of the incisors with irregular root resorption was significantly smaller than that of the incisors with simulated regular resorption (p<0.001). There was no significant difference in the comparison between total root surface areas (p=0.435). Conclusion: Underestimation of the irregular root resorption shown on two-dimensional images was significant when analyzing the apical area of the tooth. However, when considering the total root surface area of the tooth, which is responsible for the most part of the periodontal support, such underestimation was not significant.Introdução: O controle periódico da reabsorção radicular durante o tratamento ortodôntico é frequentemente realizado através de exames radiográficos bidimensionais, nos quais as reabsorções irregulares não são detectadas no sentido vestibulolingual. Objetivo: Quantificar a área reabsorvida de raízes de incisivos com reabsorção radicular apical irregular subestimada por exames radiográficos bidimensionais. Material e Métodos: Foram avaliadas imagens de tomografia computadorizada de feixe cônico de 18 pacientes que apresentavam incisivos superiores com reabsorção radicular apical irregular substimada por exames radiográficos bidimensionais (grupo experimental) e os incisivos correspondentes contralaterais sem reabsorção radicular (grupo controle). No grupo controle foi simulada uma reabsorção radicular apical regular na mesma altura da encontrada nos incisivos com reabsorção irregular. As áreas apical e total das raízes dos incisivos com reabsorção radicular irregular e regular simulada foram avaliadas e comparadas. O teste t de Student para amostras pareadas foi utilizado, sendo considerado um nível de significância de 0,05. Resultados: A área apical nos incisvos com reabsorção radicular irregular foi significativamente menor do que nos incisivos com reabsorção radicular regular simulada (p<0,001). Não houve diferença significativa entre as áreas radiculares totais (p=0,435). Conclusão: A reabsorção radicular irregular foi significativamennte subestimada em imagens radiográficas bidimensionais quando a área apical radicular foi analisada. Entretanto, quando a área radicular total é considerada, a qual é responsável pela maior parte do suporte periodontal, esta subestimativa não foi significativa

    Análise do processo de corrosão na falha clínica de mini-implantes ortodônticos

    No full text
    Resumo Introdução Mini-implantes ortodônticos são dispositivos de ancoragem confeccionados à base de titânio, possuindo uma camada de óxido de titânio, que desempenha função importante na resistência à corrosão. Objetivo O objetivo deste estudo foi avaliar a resistência à corrosão e a microestrutura superficial de mini-implantes novos, utilizados que foram perdidos precocemente e os que obtiveram sucesso de estabilidade, analisando se o processo de corrosão influencia a falha ou a perda de estabilidade, a fim de se comparar com as principais causas de sucesso e insucesso clínico. Material e método A amostra foi composta por 3 grupos de 7 mini-implantes divididos da seguinte maneira: Grupo C: mini-implantes na sua forma original, como são recebidos do fabricante (controle); Grupo PE: mini-implantes utilizados em pacientes e que apresentaram perda de estabilidade precoce em até 2 meses (média de 33,5 dias); Grupo E: mini-implantes utilizados em pacientes com sucesso de estabilidade (média de 230 dias). A análise visual da superfície da rosca dos mini-implantes foi feita através de microscópio eletrônico de varredura e todos foram submetidos a ensaio de polarização cíclica potenciodinâmica em potenciostato. Resultado A microestrutura superficial não foi significativamente alterada pela permanência e perda precoce de estabilidade em seus sítios ósseos. Conclusão Os dados sugeriram que a corrosão não foi fator associado à falha do dispositivo ou perda de sua estabilidade, sendo outros fatores, como o tipo do mini-implante, o seu comprimento e o local de implantação, considerados mais preponderantes com influência no seu insucesso