895 research outputs found

    Narrow Linewidth 780 nm Distributed Feedback Lasers for Cold Atom Quantum Technology

    Get PDF
    Cold atom quantum technology systems have a wide range of potential applications which includes atomic clocks, rotational sensors, inertial sensors, quantum navigators, magnetometers and gravimeters. The UK Quantum Technology Hub in Sensors and Metrology has the aim of developing miniature cold atom systems using an approach similar to that pioneered by the chip scale atomic clock where microfabricated vacuum chambers have atomic transitions excited and probed by lasers. Whilst narrow linewidth Ti:Sa and external cavity diode lasers have been required for cooling and control, such lasers are too large, power hungry and expensive for future miniature cold atom systems. Here we demonstrate 1 mm long 780.24 nm GaAs/AlGaAs distributed feedback (DFB) lasers aimed at 87Rb cold atom systems operating at 20 ˚C with over 50 mW of power and side-mode suppression ratios of 46 dB using sidewall gratings and no regrowth. Rb spectroscopy is used to demonstrate linewidths below the required 6.07 MHz natural linewidth of the 87Rb D2 optical transition used for cooling. Initial packaged fibre-coupled devices demonstrate lifetimes greater than 200 hours. We also investigate the use of integrated semiconductor amplifiers (SOAs) and longer devices to further reduce the linewidths well below 1 MHz. A range of options to control the populations of electrons in the hyperfine split energy levels spaced by 3.417 GHz are examined. Two integrated lasers, integrated electro-absorption modulators (EAMs) and the direct modulation of a single DFB laser approaches are investigated and we will discuss which is best suited to integrated cold atom systems

    Mental models or probabilistic reasoning or both: Reviewing the evidence for and implications of dual-strategy models of deductive reasoning

    Get PDF
    The present paper presents an overview of contemporary reasoning research to examine the evidence for and implications of the Dual Strategy Model of Reasoning. The Dual Strategy Model of Reasoning proposes that there are two types of reasoning strategy applied in deductive reasoning – counterexample and statistical. The paper considers Mental Models Theory and The Probability Heuristics Model as candidate specifications for these respective strategies and hypotheses are proposed on this basis. The Dual Strategy Model is further considered in the context of Dual Process theory, the Dual Source Model and Meta-reasoning and implications of the synergy between these proposals are considered. We finally consider the Dual Strategy Model in the context of individual differences, and normative considerations before proposing novel hypotheses and further avenues of research which we argue require exploration in this context.N/

    Turbulent drag on a low-frequency vibrating grid in superfluid He-4 at very low temperatures

    Get PDF
    We present measurements of the dissipative turbulent drag on a vibrating grid in superfluid He-4 over a wide range of (low) frequencies. At high velocities, the dissipative drag is independent of frequency and is approximately the same as that measured in normal liquid He-4. We present measurements on a similar grid in superfluid He-3-B at low temperatures which shows an almost identical turbulent drag coefficient at low frequencies. However, the turbulent drag in He-3-B is substantially higher at higher frequencies. We also present measurements of the inertial drag coefficient for grid turbulence in He-4. The inertial drag coefficient is significantly reduced by turbulence in both superfluid and normal liquid He-4

    A novel method for measuring bowel motility and velocity with dynamic magnetic resonance imaging in two and three dimensions

    Get PDF
    Increasingly, dynamic MRI has potential as a non-invasive and accessible tool for diagnosing and monitoring gastrointestinal motility in healthy and diseased bowel. However, current MRI methods of measuring bowel motility have limitations: requiring bowel preparation or long acquisition times; providing mainly surrogate measures of motion; and estimating bowel-wall movement in just two dimensions. In this proof-of-concept study we apply a method that provides a quantitative measure of motion within the bowel, in both 2D and 3D, using existing, vendor-implemented MRI pulse sequences with minimal bowel-preparation. This method uses a minimised cost function to fit linear vectors in the spatial and temporal domains. It is sensitised to the spatial scale of the bowel and aims to address issues relating to the low signal-to-noise in high-temporal resolution dynamic MRI scans, previously compensated for by performing thick-slice (10 mm) 2D coronal scans. We applied both 2D and 3D scanning protocols in two healthy volunteers. For 2D scanning, analysis yielded bi-modal velocity peaks, with a mean antegrade motion of 5.5 mm/s and an additional peak at ~9 mm/s corresponding to longitudinal peristalsis, as supported by intra-operative data from the literature. Furthermore, 3D scans indicated a mean forward motion of 4.7 mm/s, and degrees of ante- and retrograde motion were also established. These measures show promise for the non-invasive assessment of bowel motility, and have the potential to be tuned to particular regions of interest and behaviours within the bowel

    Elevated expression of caspase-3 inhibitors, survivin and xIAP correlates with low levels of apoptosis in active rheumatoid synovium

    Get PDF
    Introduction: Tumour necrosis factor-related apoptosis-inducing ligand (TRAIL) is a tumour necrosis factor (TNF) family member capable of inducing apoptosis in many cell types. Methods: Using immunohistochemistry, terminal deoxynucleotidyl transferase biotin-dUTP nick end labelling (TUNEL) and real-time PCR we investigated the expression of TRAIL, TRAIL receptors and several key molecules of the intracellular apoptotic pathway in human synovial tissues from various types of arthritis and normal controls. Synovial tissues from patients with active rheumatoid arthritis (RA), inactive RA, osteoarthritis (OA) or spondyloarthritis (SpA) and normal individuals were studied. Results Significantly higher levels of TRAIL, TRAIL R1, TRAIL R2 and TRAIL R4 were observed in synovial tissues from patients with active RA compared with normal controls (p < 0.05). TRAIL, TRAIL R1 and TRAIL R4 were expressed by many of the cells expressing CD68 (macrophages). Lower levels of TUNEL but higher levels of cleaved caspase-3 staining were detected in tissue from active RA compared with inactive RA patients (p < 0.05). Higher levels of survivin and x-linked inhibitor of apoptosis protein (xIAP) were expressed in active RA synovial tissues compared with inactive RA observed at both the protein and mRNA levels. Conclusions: This study indicates that the induction of apoptosis in active RA synovial tissues is inhibited despite stimulation of the intracellular pathway(s) that lead to apoptosis. This inhibition of apoptosis was observed downstream of caspase-3 and may involve the caspase-3 inhibitors, survivin and xIAP.Anak ASSK Dharmapatni, Malcolm D Smith, David M Findlay, Christopher A Holding, Andreas Evdokiou, Michael J Ahern, Helen Weedon, Paul Chen, Gavin Screaton, Xiao N Xu and David R Hayne

    Parameter Estimation Error Dependency on the Acquisition Protocol in Diffusion Kurtosis Imaging

    Get PDF
    Mono-exponential kurtosis model is routinely fitted on diffusion weighted, magnetic resonance imaging data to describe non-Gaussian diffusion. Here, the purpose was to optimize acquisitions for this model to minimize the errors in estimating diffusion coefficient and kurtosis. Similar to a previous study, covariance matrix calculations were used, and coefficients of variation in estimating each parameter of this model were calculated. The acquisition parameter, b values, varied in discrete grids to find the optimum ones that minimize the coefficient of variation in estimating the two non-Gaussian parameters. Also, the effect of variation of the target values on the optimized values was investigated. Additionally, the results were benchmarked with Monte Carlo noise simulations. Simple correlations were found between the optimized b values and target values of diffusion and kurtosis. For small target values of the two parameters, there is higher chance of having significant errors; this is caused by maximum b value limits imposed by the scanner than the mathematical bounds. The results here, cover a wide range of parameters D and K so that they could be used in many directionally averaged diffusion weighted cases such as head and neck, prostate, etc

    Calibration of myocardial T2 and T1 against iron concentration.

    Get PDF
    BACKGROUND: The assessment of myocardial iron using T2* cardiovascular magnetic resonance (CMR) has been validated and calibrated, and is in clinical use. However, there is very limited data assessing the relaxation parameters T1 and T2 for measurement of human myocardial iron. METHODS: Twelve hearts were examined from transfusion-dependent patients: 11 with end-stage heart failure, either following death (n=7) or cardiac transplantation (n=4), and 1 heart from a patient who died from a stroke with no cardiac iron loading. Ex-vivo R1 and R2 measurements (R1=1/T1 and R2=1/T2) at 1.5 Tesla were compared with myocardial iron concentration measured using inductively coupled plasma atomic emission spectroscopy. RESULTS: From a single myocardial slice in formalin which was repeatedly examined, a modest decrease in T2 was observed with time, from mean (± SD) 23.7 ± 0.93 ms at baseline (13 days after death and formalin fixation) to 18.5 ± 1.41 ms at day 566 (p<0.001). Raw T2 values were therefore adjusted to correct for this fall over time. Myocardial R2 was correlated with iron concentration [Fe] (R2 0.566, p<0.001), but the correlation was stronger between LnR2 and Ln[Fe] (R2 0.790, p<0.001). The relation was [Fe] = 5081•(T2)-2.22 between T2 (ms) and myocardial iron (mg/g dry weight). Analysis of T1 proved challenging with a dichotomous distribution of T1, with very short T1 (mean 72.3 ± 25.8 ms) that was independent of iron concentration in all hearts stored in formalin for greater than 12 months. In the remaining hearts stored for <10 weeks prior to scanning, LnR1 and iron concentration were correlated but with marked scatter (R2 0.517, p<0.001). A linear relationship was present between T1 and T2 in the hearts stored for a short period (R2 0.657, p<0.001). CONCLUSION: Myocardial T2 correlates well with myocardial iron concentration, which raises the possibility that T2 may provide additive information to T2* for patients with myocardial siderosis. However, ex-vivo T1 measurements are less reliable due to the severe chemical effects of formalin on T1 shortening, and therefore T1 calibration may only be practical from in-vivo human studies

    Cadmium, Lead, and Mercury in Relation to Reproductive Hormones and Anovulation in Premenopausal Women

    Get PDF
    Background: Metals can interfere with hormonal functioning by binding at the receptor site and through indirect mechanisms; thus, they may be associated with hormonal changes in premenopausal women

    Impact of source data on the interpretation of contrast-enhanced magnetic resonance angiography of the lower limbs

    Get PDF
    Background The primary purpose of this study is to examine whether use of source data is effective in increasing the number of arterial segments that can be interpreted from maximum intensity projections of lower limb MR angiograms. Correlation between sites of arterial disease and venous contamination was also measured. Interpretation of source data is performed routinely by radiologists, but the value of this has not been well studied with randomized studies. Results The proportion of segments visible above the knee was 87% using maximal intensity projection alone (MIP) and 88% when the MIP was combined with source data. The proportions were 67% for MIP and 72% for MIP plus source data below the knee. There was substantial agreement between presence of arterial disease and venous contamination in the calf and thigh. Conclusion The use of source data increases the number of assessable segments, but not individuals, by a statistically significant but small amount (1.2%, p <0.05). This study supports the association between arterial disease and venous contamination
    corecore