17 research outputs found

    Emergent Percutaneous Rotational Atherectomy to Bailout Surgical Transapical Aortic Valve Implantation: A Successful Case of Heart Team Turnaround.

    No full text
    Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis (AS) in patients with elevated surgical risk. Concomitant coronary artery disease affects 55-70% of patients with severe AS. Percutaneous coronary intervention in patients with TAVI can be challenging. We report a case of acute coronary obstruction immediately following transapical TAVI deployment requiring emergent rotational atherectomy

    Impact of Obesity on Noninvasive Cardiac Hemodynamic Measurement by Electrical Cardiometry in Adults With Aortic Stenosis.

    No full text
    Objectives There are substantial potential benefits to noninvasive cardiac monitoring methods, such as electrical cardiometry (EC), over more invasive methods, including significantly reduced risk of complications, lower up-front and operational costs, ease of use, and continuous monitoring. To take advantage of these technologies, clinical equivalence to currently established methods must be determined. The authors sought to determine if the noninvasive measurement of cardiac index (CI) by EC was clinically equivalent to thermodilution (TD) in adult patients with aortic stenosis (AS). Design This is a cross-sectional study comparing measurement devices in a single patient group. Setting Single-center, university teaching hospital. Participants The study included 52 adult patients with aortic stenosis undergoing right heart catheterization. Interventions Cardiac output (CO) was measured concurrently using EC with an ICON device and TD in 52 participants with AS. CI values were to determine the accuracy and precision of EC in reference to TD. Percentage error (PE) was used to assess their clinical equivalence. The participants were divided further into groups (normal and overweight/obese) based on body mass index and the analysis was repeated. Measurements and Main Results CO measurement made by EC in adult patients with obesity or overweight was reduced significantly relative to TD. This was not observed in normal-weight adult AS patients. EC provided clinically equivalent measurements to TD for measuring CI in normal-weight adult AS patients (PE = 25.0%), but not for those adult AS patients with overweight or obesity (PE = 42.3%). Conclusion Overall, the ICON device produced lower CO and index measurements relative to TD in adult patients with AS. Overweight and obesity also significantly affected the relative precision and accuracy of the ICON electrical cardiometric device to measure CI in these patients

    Constrictive Pericarditis Associated with Atypical Antipsychotics

    No full text
    We report the successful surgical intervention in a case of constrictive pericarditis after long-term use of atypical antipsychotics. Pericarditis developed in our patient with a longstanding history of schizophrenia treated with atypical antipsychotics. Pericardiectomy was undertaken, and the patient's presenting symptom of shortness of breath resolved subsequently with an uneventful postoperative course

    Cubic-Spline Interpolation for Sparse-View CT Image Reconstruction With Filtered Backprojection in Dynamic Myocardial Perfusion Imaging

    No full text
    We investigated a projection interpolation method for reconstructing dynamic contrast-enhanced (DCE) heart images from undersampled x-ray projections with filtered backprojecton (FBP). This method may facilitate the application of sparse-view dynamic acquisition for ultralow-dose quantitative computed tomography (CT) myocardial perfusion (MP) imaging. We conducted CT perfusion studies on 5 pigs with a standard full-view acquisition protocol (984 projections). We reconstructed DCE heart images with FBP from all and a quarter of the measured projections evenly distributed over 360°. We interpolated the sparse-view (quarter) projections to a full-view setting using a cubic-spline interpolation method before applying FBP to reconstruct the DCE heart images (synthesized full-view). To generate MP maps, we used 3 sets of DCE heart images, and compared mean MP values and biases among the 3 protocols. Compared with synthesized full-view DCE images, sparse-view DCE images were more affected by streak artifacts arising from projection undersampling. Relative to the full-view protocol, mean bias in MP measurement associated with the sparse-view protocol was 10.0 mL/min/100 g (95%CI: −8.9 to 28.9), which was >3 times higher than that associated with the synthesized full-view protocol (3.3 mL/min/100 g, 95% CI: −6.7 to 13.2). The cubic-spline-view interpolation method improved MP measurement from DCE heart images reconstructed from only a quarter of the full projection set. This method can be used with the industry-standard FBP algorithm to reconstruct DCE images of the heart, and it can reduce the radiation dose of a whole-heart quantitative CT MP study to <2 mSv (at 8-cm coverage)